MS27473E10F35A

Manufacturer Part Number:
MS27473E10F35A
Manufacturer / Brand
Souriau-Sunbank by Eaton
Part of Description:
8T 13C 13#22D PLUG
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 28623 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number MS27473E10F35A
Manufacturer / Brand Souriau-Sunbank by Eaton
Stock Quantity 28623 pcs Stock
Category Connectors, Interconnects > Circular Connectors - Circular Connector Housings
Description 8T 13C 13#22D PLUG
Lead Free Status / RoHS Status: ROHS3 Compliant
Series *
Package Bulk
Base Product Number MS27473E10F

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

What should I check before using MS27473E10F35A in a MIL-style cable assembly replacement?
For MS27473E10F35A, verify shell size, contact arrangement, coupling style, and keying against the mating receptacle before committing to a replacement build. In practice, the connector may fit mechanically but still fail to mate if the insert arrangement or shell polarization differs from the existing harness. It is also common to confirm backshell, strain relief, and cable OD compatibility early, since those items often determine whether the replacement can survive vibration and repeated servicing.
Can MS27473E10F35A be used in an environment with high vibration or frequent disconnects?
MS27473E10F35A can be suitable when the mating system, locking method, and cable termination are selected for vibration exposure. In field equipment, the connector body alone is only part of the solution; proper mating halves, correct crimp or solder termination, and strain relief usually determine retention and long-term stability. For frequent disconnects, check contact wear expectations and whether the application needs additional mechanical protection such as cable support or connector backshell hardware.
How do I confirm that MS27473E10F35A is compatible with my existing receptacle or cable harness?
With MS27473E10F35A, compatibility should be checked at three levels: mechanical interface, contact arrangement, and termination method. Engineers typically compare the exact part numbering of both halves, verify polarization so the shell will align correctly, and confirm that the wire gauge and contact style match the harness build. If the existing design uses a different insert pattern or a different environmental sealing approach, the connector may require redesign rather than direct drop-in replacement.
Is MS27473E10F35A a good choice for replacing a similar connector from another brand?
MS27473E10F35A may work as a replacement when the alternate part follows the same military-style circular connector standard, but cross-brand substitution still needs dimensional and functional checks. Small differences in shell finish, coupling torque, contact tolerance, and accessory compatibility can affect fit and serviceability. When migrating from another brand, engineers usually validate mating dimensions, termination tooling, and environmental sealing so the replacement does not introduce assembly or maintenance issues.
What design issues can appear if MS27473E10F35A is used with an incompatible mating half?
If MS27473E10F35A is paired with the wrong mating half, the usual problems are incomplete engagement, pin or socket damage, and unreliable contact pressure. Even when the connector appears close in size, a mismatched keying scheme or insert arrangement can prevent full coupling. In a system build, this often shows up later as intermittent continuity, higher insertion force, or maintenance difficulty, so mating-part verification is normally done before harness fabrication.
What should I consider for wiring and termination when installing MS27473E10F35A in a new harness?
For MS27473E10F35A, the termination method should match the contact type, wire size, and assembly process used in your facility. A build can pass basic continuity checks yet still fail under vibration if crimp height, conductor fill, or insulation support is outside the connector family’s normal practice. It is also useful to confirm whether the project needs field-serviceable assembly or controlled factory termination, since that affects tooling, inspection, and repair workflow.
Can MS27473E10F35A be used in industrial equipment that runs continuously for long periods?
MS27473E10F35A can be used in continuous-duty systems if thermal conditions, contact loading, and environmental exposure remain within the connector family’s expected operating envelope. In long-running equipment, contact resistance drift and cable strain are usually more relevant than nominal fit alone. Engineers often review mating cycle count, ambient temperature around the connector, and contamination exposure so the harness remains stable over time.
How does MS27473E10F35A compare with other Amphenol Aerospace circular connectors for redesign projects?
MS27473E10F35A should be evaluated by its exact shell and contact configuration rather than only by the Amphenol Aerospace name. In redesign work, nearby part numbers may differ in shell size, keying, service class, or accessory compatibility even if they look similar in the catalog. The practical comparison usually comes down to whether the new connector preserves harness geometry, mating compatibility, and maintenance access without requiring a PCB or cable layout change.
What are the most common reasons MS27473E10F35A fails in the field?
Field issues with MS27473E10F35A are often related to installation details rather than the connector body itself. Typical causes include incomplete mating, damaged contacts from misalignment, insufficient strain relief, contamination at the interface, and cable movement that loads the termination. In rugged systems, occasional inspection of coupling condition and harness routing usually helps catch these issues before intermittent faults appear.
Is MS27473E10F35A suitable for applications that may be exposed to moisture, dust, or handling contamination?
MS27473E10F35A may be suitable if the full connector system, including the mating half, seals, accessories, and termination method, is specified for the exposure level in question. The connector should be evaluated as part of the complete assembly, since sealing performance depends on the interface and the cable entry as much as the plug itself. For harsh environments, designers usually confirm environmental ratings and add protective caps, backshells, or harness routing measures where needed.
What should I verify if I want to substitute MS27473E10F35A in an existing certified design?
When substituting MS27473E10F35A into a certified or controlled design, verify compliance traceability, exact part revision, mating compatibility, and any required documentation updates. Even when two parts appear equivalent, certification files often depend on the specific shell finish, contact arrangement, and approved accessory set. The usual workflow is to compare drawings and qualification references, then confirm that the revised connector does not alter the system’s mechanical envelope or environmental behavior.
How can I tell whether MS27473E10F35A is the right connector if my project may later need service replacement?
MS27473E10F35A is a practical candidate when you need a serviceable circular connector format and can keep the mating interface consistent across field replacements. For maintainability, engineers usually check whether technicians can access the coupling, whether the connector is keyed to reduce mis-mating, and whether the harness can be re-terminated with available tooling. If future service access is limited, selecting matching backshell and strain-relief hardware alongside MS27473E10F35A often makes later replacement easier.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


MS27473E10F35A

Souriau-Sunbank by Eaton

8T 13C 13#22D PLUG

In Stock: 28623

Submit RFQ