Choose your country or region.

Image may be representation.
See specs for product details.

IUG1-1-52-3.00-AQ-01

In Stock 1094 pcs Reference Price(In US Dollars)
3+
$36.1651
Manufacturer Part Number:
IUG1-1-52-3.00-AQ-01
Manufacturer / Brand
Sensata-Airpax
Part of Description:
CIR BRKR MAG-HYDR LEVER 3A
Datasheets:
IUG1-1-52-3.00-AQ-01.pdf
Lead Free Status / RoHS Status:
RoHS Compliant
Stock Condition:
New original, 1094 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number IUG1-1-52-3.00-AQ-01
Manufacturer / Brand Sensata-Airpax
Stock Quantity 1094 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIR BRKR MAG-HYDR LEVER 3A
Lead Free Status / RoHS Status: RoHS Compliant
Series IUG
Package Bulk
Number of Poles 1
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Illumination -
Current Rating (Amps) 3A
Breaker Type Magnetic (Hydraulic Delay)
Base Product Number IUG1
Actuator Type Lever

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can I use IUG1-1-52-3.00-AQ-01 on both AC and DC rails in the same system?
Yes, IUG1-1-52-3.00-AQ-01 can be used in AC or DC applications only when the voltage, interrupting capacity, and wiring conditions are matched to the specific supply. For DC circuits, arc extinction is generally more demanding than AC, so the system voltage and fault current must be checked carefully. In practice, engineers should verify the exact voltage rating on the IUG1-1-52-3.00-AQ-01 datasheet, then confirm that the breaker can safely interrupt the worst-case fault current on each rail.
Is IUG1-1-52-3.00-AQ-01 a suitable replacement for a fuse in a design with frequent inrush current?
IUG1-1-52-3.00-AQ-01 is often chosen when a resettable protective device is preferred and when startup surges would nuisance-trip a faster thermal device or fuse. Its magnetic-hydraulic behavior is typically better suited to short inrush events than a purely thermal mechanism. That said, IUG1-1-52-3.00-AQ-01 should not be assumed to replace semiconductor protection or coordination fusing without testing, because fault-clearing behavior and let-through energy still need to be validated in the actual circuit.
Can IUG1-1-52-3.00-AQ-01 protect motors, solenoids, or transformer loads without nuisance tripping?
IUG1-1-52-3.00-AQ-01 can be a practical choice for inductive loads if the inrush profile is short and the steady-state current stays within the intended operating range. The magnetic-hydraulic delay helps tolerate brief current peaks, but repeated long inrush events, high ambient temperature, or poor ventilation can shift the effective trip behavior. For motor or transformer use, validate the worst-case startup current, ambient temperature, and duty cycle on IUG1-1-52-3.00-AQ-01 before releasing the design.
What should I check before panel mounting IUG1-1-52-3.00-AQ-01 in an enclosure?
For IUG1-1-52-3.00-AQ-01, confirm the panel cutout, panel thickness, lever travel clearance, terminal access, and rear-side space for wiring bend radius and serviceability. Also verify torque requirements, wire gauge, and any needed sealing method if the enclosure requires dust or splash protection. Because panel hardware varies by chassis design, the mechanical outline drawing for IUG1-1-52-3.00-AQ-01 should be matched to the actual enclosure stack-up before tooling is frozen.
Can IUG1-1-52-3.00-AQ-01 be used as the main disconnect for lockout/tagout?
IUG1-1-52-3.00-AQ-01 is an overcurrent protective device, but it should not automatically be treated as the only isolation method unless the system and applicable safety standard explicitly allow that arrangement. If the application requires a lockable off-state or visible isolation, engineers usually add a dedicated disconnect switch or a breaker arrangement with the required isolation and lockout hardware. For IUG1-1-52-3.00-AQ-01, confirm the installation method meets the site’s LOTO and maintenance requirements.
How suitable is IUG1-1-52-3.00-AQ-01 for industrial equipment exposed to vibration or temperature swings?
IUG1-1-52-3.00-AQ-01 is generally a reasonable option for industrial panels because magnetic-hydraulic breakers tend to be less sensitive to ambient temperature drift than purely thermal devices. Even so, vibration, shock, humidity, contamination, and corrosion can affect the mounting, terminals, and actuator feel over time. For long-term industrial use, IUG1-1-52-3.00-AQ-01 should be validated in the final enclosure under the expected temperature range, vibration profile, and service interval.
Can I cross-reference IUG1-1-52-3.00-AQ-01 to an equivalent breaker from another brand?
IUG1-1-52-3.00-AQ-01 can sometimes be replaced by a functionally similar breaker from another brand, but it should not be assumed to be a direct drop-in. Mechanical fit, panel cutout, terminal orientation, lever projection, trip behavior, and certification differences often matter as much as the current rating. When comparing IUG1-1-52-3.00-AQ-01 with alternatives from Eaton, Carling, or E-T-A, check the outline drawing, mounting method, voltage rating, and time-current behavior before approving the substitute.
Should I choose IUG1-1-52-3.00-AQ-01 instead of a thermal breaker or electronic protector?
IUG1-1-52-3.00-AQ-01 is a good fit when you want resettable protection with better tolerance to inrush and ambient temperature variation than a thermal breaker. A thermal breaker may be lower cost, but its trip point is more affected by temperature and sustained overload behavior. An electronic protector can provide tighter control, remote status, or diagnostics, but it adds circuitry and integration effort. For compact power distribution, IUG1-1-52-3.00-AQ-01 is often selected when mechanical simplicity and predictable manual reset behavior are preferred.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


IUG1-1-52-3.00-AQ-01

Sensata-Airpax

CIR BRKR MAG-HYDR LEVER 3A

In Stock: 1094

SUBMIT RFQ