Choose your country or region.

Image may be representation.
See specs for product details.

IEGZX66-1-62-30.0-A-22-V

Manufacturer Part Number:
IEGZX66-1-62-30.0-A-22-V
Manufacturer / Brand
Sensata Technologies, Airpax
Part of Description:
CIRCUIT BREAKER
Datasheets:
IEGZX66-1-62-30.0-A-22-V.pdf
Lead Free Status / RoHS Status:
Lead free / RoHS Compliant
Stock Condition:
New original, 41877 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number IEGZX66-1-62-30.0-A-22-V
Manufacturer / Brand Sensata Technologies, Airpax
Stock Quantity 41877 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIRCUIT BREAKER
Lead Free Status / RoHS Status: Lead free / RoHS Compliant
Voltage Rating - DC 80V
Voltage Rating - AC 240V
Standard Package 1
Series IEG
Part Status Active
Number of Poles 2
Mounting Type Panel Mount
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Lead Free Status / RoHS Status Lead free / RoHS Compliant
Illumination Voltage (Nominal) -
Illumination -
Current Rating 30A
Breaker Type Magnetic (Hydraulic Delay)
Actuator Type Rocker

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

What are the key design considerations when integrating the IEGZX66-1-62-30.0-A-22-V into a 240V AC panel with mixed inductive and resistive loads?
The IEGZX66-1-62-30.0-A-22-V is a two-pole hydraulic-magnetic circuit breaker with a 30A rating and rocker actuator for panel mount. Its hydraulic delay mechanism provides consistent trip behavior across a wide temperature range, allowing the breaker to tolerate normal inrush currents from inductive loads such as motors or transformers without nuisance tripping, while still offering magnetic protection for short circuits. Engineers should verify that the combined inrush profile of the loads stays below the delay curve thresholds and ensure proper panel cutout dimensions for the rocker style to maintain secure mounting and access.
Can the IEGZX66-1-62-30.0-A-22-V be used in systems with significant ambient temperature variations, such as outdoor enclosures or industrial control cabinets?
The hydraulic-magnetic design of the IEGZX66-1-62-30.0-A-22-V results in trip characteristics that remain largely independent of ambient temperature, unlike thermal-magnetic breakers whose bimetallic elements shift with heat. This behavior supports operation from -40°C to +85°C, making the part suitable for environments where temperature swings occur, provided the overall system voltage stays within the 240V AC or 80V DC ratings and vibration levels align with standard MIL-STD-202 test conditions for non-tripping performance.
What configuration options exist for the actuator and mounting when replacing an existing single-pole breaker with the IEGZX66-1-62-30.0-A-22-V in a multi-circuit setup?
The IEGZX66-1-62-30.0-A-22-V features a two-pole configuration with a rocker actuator and is designed for panel mount. When migrating from single-pole units, designers typically need to adjust the panel layout for the wider two-pole footprint and ensure independent or ganged pole operation matches the application. The rocker provides visible ON/OFF indication, and the trip-free mechanism prevents holding the contacts closed under overload conditions.
How does the hydraulic delay in the IEGZX66-1-62-30.0-A-22-V affect its suitability for protecting power supplies with high startup inrush compared to instantaneous magnetic breakers?
The hydraulic delay in the IEGZX66-1-62-30.0-A-22-V introduces a time element that allows brief overcurrents during equipment startup, reducing the likelihood of nuisance trips on capacitive or inductive inrush. This differs from purely instantaneous magnetic types, which may trip on the same surge. Selection involves reviewing the specific delay curve (typically medium or standard for the 62 delay code) against the load's inrush waveform to confirm coordination without compromising short-circuit protection.
When considering replacement of a thermal-magnetic circuit breaker with the IEGZX66-1-62-30.0-A-22-V, what practical differences in performance should engineers evaluate?
Switching to the IEGZX66-1-62-30.0-A-22-V hydraulic-magnetic breaker means the trip point experiences minimal shift with ambient temperature changes, offering more repeatable protection in variable conditions. Thermal-magnetic alternatives often require derating or compensation curves in hot or cold environments. The two-pole IEGZX66 model also provides simultaneous disconnection of both lines, which can simplify wiring in AC applications up to 240V while maintaining the 30A rating.
Is the IEGZX66-1-62-30.0-A-22-V appropriate for long-term use in vibration-prone industrial machinery or transportation equipment?
The IEGZX66-1-62-30.0-A-22-V withstands vibration per MIL-STD-202 Method 204 without tripping when carrying up to 100% rated current on delayed units. Its robust construction and hydraulic-magnetic principle contribute to mechanical endurance exceeding 10,000 operations. Designers should still confirm that mounting hardware secures the panel mount assembly adequately for the specific vibration spectrum and that the 80V DC rating is observed if used in mixed AC/DC systems.
What power supply and voltage compatibility factors need review before specifying the IEGZX66-1-62-30.0-A-22-V in a design that includes both AC and DC sections?
The IEGZX66-1-62-30.0-A-22-V supports 240V AC and 80V DC across its two poles. For dual-voltage designs, engineers must ensure the DC portion does not exceed 80V and that polarity is observed where applicable. The magnetic sensing operates independently on each pole, but simultaneous tripping occurs on overload. Clearance and creepage distances should meet the target safety standards, as the part carries UL1077 supplementary protector recognition, CSA, and TUV approvals.
Are there notable trade-offs when migrating from a UL489 branch circuit breaker to the IEGZX66-1-62-30.0-A-22-V in equipment protection applications?
The IEGZX66-1-62-30.0-A-22-V is recognized as a supplementary protector under UL1077 rather than a primary branch circuit device under UL489. This distinction means it is typically applied downstream of a main protector or in equipment-level protection where the upstream device handles short-circuit interrupting capacity. The hydraulic-magnetic performance provides temperature-stable tripping, but system designers must verify overall coordination and interrupting ratings for the specific fault levels expected.
How should engineers approach long-term reliability testing when incorporating the IEGZX66-1-62-30.0-A-22-V into systems requiring extended service life in harsh conditions?
The IEGZX66-1-62-30.0-A-22-V demonstrates mechanical endurance through repeated switching cycles and maintains trip consistency due to its hydraulic-magnetic construction, which avoids the aging effects seen in some thermal elements. In industrial scenarios, periodic functional checks of the rocker actuation and verification that operating temperatures remain within -40°C to +85°C help sustain performance over time. The RoHS-compliant build and unlimited MSL support standard manufacturing and storage practices.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


IEGZX66-1-62-30.0-A-22-V

Sensata Technologies, Airpax

CIRCUIT BREAKER

In Stock: 41877

Submit RFQ