Choose your country or region.

Image may be representation.
See specs for product details.

IAGN11-1REC4-63-20.0

In Stock 1762 pcs Reference Price(In US Dollars)
3+
$120.7638
Manufacturer Part Number:
IAGN11-1REC4-63-20.0
Manufacturer / Brand
Sensata-Airpax
Part of Description:
CIR BRKR MAG-HYDR LEVER
Datasheets:
IAGN11-1REC4-63-20.0.pdf
Lead Free Status / RoHS Status:
RoHS Compliant
Stock Condition:
New original, 1762 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number IAGN11-1REC4-63-20.0
Manufacturer / Brand Sensata-Airpax
Stock Quantity 1762 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIR BRKR MAG-HYDR LEVER
Lead Free Status / RoHS Status: RoHS Compliant
Voltage Rating - DC 80 V
Voltage Rating - AC 250 V
Series IAG
Package Bulk
Number of Poles 2
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 20A
Breaker Type Magnetic (Hydraulic Delay)
Base Product Number IAGN11-1REC4
Actuator Type Toggle

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can I use IAGN11-1REC4-63-20.0 on a DC system up to 80 V, or do I need extra derating for inrush and inductive loads?
IAGN11-1REC4-63-20.0 is rated for 80 V DC, but the usable margin depends on the load profile, not just the nominal bus voltage. For motor loads, capacitive input stages, solenoids, or long cable runs, the interrupting stress can exceed the steady-state voltage by a wide margin. In practice, engineers often verify the fault current, the source impedance, and the worst-case transient energy before committing IAGN11-1REC4-63-20.0 to a DC design. If the circuit has high inrush or significant inductance, confirm the breaker’s DC interrupt behavior in the actual system rather than assuming the nameplate voltage alone is sufficient.
Is IAGN11-1REC4-63-20.0 suitable for replacing a fuse in a 20 A industrial power branch?
IAGN11-1REC4-63-20.0 can replace a fuse when the goal is resettable branch protection, but the trip behavior is not identical to a fuse. A magnetic-hydraulic breaker tolerates short-duration overloads differently from a fuse, so the downstream equipment may see more energy before interruption. For replacement work, compare the time-current curve against the protected conductor size, connector ratings, and startup profile. IAGN11-1REC4-63-20.0 is often a practical option when maintenance needs field reset, but the coordination study should be checked if the branch feeds electronics, motors, or parallel protection devices.
Will IAGN11-1REC4-63-20.0 nuisance-trip on motor start or capacitive inrush, and how should I verify that?
IAGN11-1REC4-63-20.0 uses magnetic-hydraulic delay behavior, so it can tolerate some transient overcurrent, but the real result depends on the magnitude and duration of the inrush. For a motor or DC-DC converter input, compare the startup current waveform to the breaker’s trip curve at the expected ambient temperature. If the system has repeated starts, elevated temperature, or a weak supply, IAGN11-1REC4-63-20.0 may trip earlier than expected. The usual design check is to validate with worst-case startup data, not just average operating current.
Is IAGN11-1REC4-63-20.0 appropriate for panel-mount replacement in an existing cutout, or do I need to confirm mechanical compatibility?
Mechanical compatibility should be verified before using IAGN11-1REC4-63-20.0 as a field replacement. Even when electrical ratings match, toggle form factor, panel thickness, cutout geometry, bezel clearance, and terminal orientation can differ from the original part. In retrofit work, confirm that the actuator travel and mounting hardware align with the existing enclosure layout. IAGN11-1REC4-63-20.0 is panel mount, so it is best matched by comparing the exact front-panel and rear-termination dimensions of the incumbent device.
Can IAGN11-1REC4-63-20.0 be used on a 250 V AC circuit with repetitive switching loads?
IAGN11-1REC4-63-20.0 is rated for 250 V AC, but repetitive switching loads can create contact stress and thermal cycling that differ from static branch protection. If the circuit is switched frequently or feeds a load with high arcing potential, check the expected interrupt duty and environmental temperature. A breaker like IAGN11-1REC4-63-20.0 is generally selected for protection rather than control switching, so designs that cycle often should confirm the contact life and trip consistency under the actual duty profile.
What should I check before using IAGN11-1REC4-63-20.0 in a two-pole application with shared neutral or split DC rails?
IAGN11-1REC4-63-20.0 is a 2-pole device, so both poles should be evaluated as a coordinated pair in the intended topology. For shared-neutral AC circuits, confirm whether simultaneous disconnect is required by the system architecture and local code. For split DC rails, verify the polarity arrangement, fault return paths, and whether both conductors must open to achieve safe isolation. IAGN11-1REC4-63-20.0 can be a good fit when both lines need to be interrupted together, but the wiring diagram should be reviewed carefully to avoid unexpected backfeed paths.
Is IAGN11-1REC4-63-20.0 a good substitute if I need a similar Sensata-Airpax breaker with a different trip delay?
Sensata-Airpax offers closely related parts, but the trip delay code can change the practical behavior significantly. For example, IUGN66-1REC4-61-5.00, IUGN66-1REC4-53-10.0, and IUGN66-1-72-20.0 may look similar to IAGN11-1REC4-63-20.0, but each can respond differently to inrush, ambient temperature, and overload duration. When selecting a substitute, compare the time-current curve, mounting style, terminal layout, and panel interface rather than relying only on current rating. IAGN11-1REC4-63-20.0 should be treated as a specific coordination point, not just a 20 A generic replacement.
How do I know if IAGN11-1REC4-63-20.0 will hold up in industrial environments with vibration and temperature cycling?
IAGN11-1REC4-63-20.0 is a mechanical panel-mount breaker, so vibration, shock, and thermal cycling mainly affect the mounting integrity and terminal terminations. In industrial enclosures, the design should ensure the panel cutout is stable, the hardware is properly torqued, and the conductors are strain-relieved. Temperature changes can also shift trip behavior in magnetic-hydraulic breakers, so validation at the actual ambient range is useful. IAGN11-1REC4-63-20.0 is often used in equipment panels, but the full assembly should be evaluated for vibration loosening and connector heating.
If my board or enclosure already has a different Airpax breaker, can I replace it with IAGN11-1REC4-63-20.0 without requalification?
Not automatically. IAGN11-1REC4-63-20.0 may share a family relationship with other Airpax parts, but replacement still requires checking the trip characteristics, mounting cutout, actuation style, and line/load terminal arrangement. Even small changes in delay behavior can affect coordination with upstream protection or downstream power supplies. If the original design depends on a specific nuisance-trip threshold, IAGN11-1REC4-63-20.0 should be tested in the target system before production substitution.
Is IAGN11-1REC4-63-20.0 suitable for equipment that needs a clearly visible manual disconnect?
IAGN11-1REC4-63-20.0 uses a toggle actuator, which provides a clear manual indication of the breaker position in a panel application. That said, whether it functions as the required disconnect depends on the circuit architecture and local safety rules. In some equipment, the breaker is used for protection and maintenance isolation, while a separate disconnect switch provides lockout capability. IAGN11-1REC4-63-20.0 can support manual reset and local status indication, but the system should be reviewed if formal lockout/tagout isolation is required.
What load types are a better fit for IAGN11-1REC4-63-20.0, and when should I consider a different protection device?
IAGN11-1REC4-63-20.0 is generally suited to branch protection where resettable overcurrent protection is needed and the load current profile is understood. It is a practical fit for control panels, instrumentation power branches, and equipment with moderate inrush that stays within the breaker’s trip envelope. If the application involves extremely high fault current, very fast semiconductor protection, or precise electronic coordination, a fuse or a different protection architecture may be easier to tune. IAGN11-1REC4-63-20.0 is strongest when the design benefits from resettable mechanical protection rather than ultra-fast electronic protection.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


IAGN11-1REC4-63-20.0

Sensata-Airpax

CIR BRKR MAG-HYDR LEVER

In Stock: 1762

Submit RFQ