Choose your country or region.

Image may be representation.
See specs for product details.

IAGN11-1REC4-39415-15

In Stock 918 pcs Reference Price(In US Dollars)
3+
$109.4555
Manufacturer Part Number:
IAGN11-1REC4-39415-15
Manufacturer / Brand
Sensata-Airpax
Part of Description:
CIR BRKR MAG-HYDR LEVER
Datasheets:
IAGN11-1REC4-39415-15.pdf
Lead Free Status / RoHS Status:
RoHS Compliant
Stock Condition:
New original, 918 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number IAGN11-1REC4-39415-15
Manufacturer / Brand Sensata-Airpax
Stock Quantity 918 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIR BRKR MAG-HYDR LEVER
Lead Free Status / RoHS Status: RoHS Compliant
Voltage Rating - DC 80 V
Voltage Rating - AC 250 V
Series IAG
Package Bulk
Number of Poles 3
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) -
Breaker Type Magnetic (Hydraulic Delay)
Base Product Number IAGN11-1REC4
Actuator Type Toggle

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can I use IAGN11-1REC4-39415-15 in a DC control panel if the system bus is below 80 V DC?
IAGN11-1REC4-39415-15 is rated for 80 V DC, so it can be considered for DC panels at or below that level only when the full operating environment, including transient events and fault conditions, stays within the device’s DC interrupting capability. In DC systems, arc extinction is more demanding than in AC, so engineers usually verify bus voltage under all conditions, expected inrush, and downstream fault current before using IAGN11-1REC4-39415-15 in a design.
Is IAGN11-1REC4-39415-15 suitable for replacing an existing 3-pole panel breaker with a toggle actuator?
IAGN11-1REC4-39415-15 can be a candidate for replacement when the existing panel cutout, mounting style, toggle geometry, pole count, and voltage ratings match closely enough to avoid mechanical rework. For retrofit projects, engineers should confirm terminal orientation, panel thickness compatibility, handle clearance, and trip behavior, since even breakers with similar ratings can differ in mounting footprint and actuation feel.
What should I check before using IAGN11-1REC4-39415-15 in a design with motor loads or transformer inrush?
IAGN11-1REC4-39415-15 uses a magnetic (hydraulic delay) trip mechanism, which can tolerate short inrush events better than many fast-acting protective devices. That said, motor starting current, transformer energization surge, and capacitive inrush should still be evaluated against the breaker’s trip curve so the circuit does not nuisance-trip during normal startup while still protecting the wiring during sustained overload or fault conditions.
How do I know if IAGN11-1REC4-39415-15 is appropriate for a 3-phase panel application?
IAGN11-1REC4-39415-15 has 3 poles, so it is commonly aligned with 3-phase distribution or three-circuit simultaneous switching where all conductors need coordinated protection or isolation. Before using it in a 3-phase panel, designers usually confirm whether neutral switching is required, whether the load is balanced, and whether the breaker’s interrupt rating and wiring method fit the system’s fault level and coordination plan.
Can IAGN11-1REC4-39415-15 be used as a direct substitute for an Airpax IAG-series breaker with a different suffix?
IAGN11-1REC4-39415-15 may be close to other Sensata-Airpax IAG-series variants, but suffix differences often indicate mechanical, electrical, or terminal variations that affect interchangeability. When substituting, engineers compare mounting dimensions, panel cutout, terminal style, pole configuration, actuator type, and trip calibration so the replacement behaves as expected in both the enclosure and the electrical protection scheme.
What are the main design risks when integrating IAGN11-1REC4-39415-15 into a compact enclosure?
With IAGN11-1REC4-39415-15, the main enclosure concerns are front-panel clearance for the toggle, conductor bend radius at the terminals, heat buildup around adjacent components, and service access for manual operation. Compact layouts should also consider finger-safe barriers, wiring strain relief, and the possibility that repeated manual cycling could be awkward if the actuator is placed near other controls.
Is IAGN11-1REC4-39415-15 a good choice for industrial equipment that runs continuously in hot environments?
IAGN11-1REC4-39415-15 can be used in industrial equipment, but continuous high ambient temperature can shift magnetic-hydraulic trip behavior and reduce the margin before nuisance operation. In long-duty applications, engineers typically review derating guidance, enclosure ventilation, adjacent heat sources, and expected load profile so the breaker remains stable over extended operating periods.
How should I verify wiring and terminal compatibility before selecting IAGN11-1REC4-39415-15?
Before selecting IAGN11-1REC4-39415-15, check the conductor size, terminal lug style, crimp or screw interface requirements, and any torque specifications associated with the installation hardware. A breaker can be electrically suitable yet still create reliability issues if the wire gauge, lug termination, or vibration environment is not matched to the panel design.
What makes IAGN11-1REC4-39415-15 different from a standard thermal breaker in practical use?
IAGN11-1REC4-39415-15 uses a magnetic (hydraulic delay) trip mechanism rather than a purely thermal element, so it typically handles short-duration surges differently and can be better aligned with loads that have repetitive inrush. In practice, this affects nuisance-trip behavior, coordination with upstream protection, and how the breaker responds to transient events versus sustained overloads.
Can IAGN11-1REC4-39415-15 be used in a design that requires frequent manual switching?
IAGN11-1REC4-39415-15 has a toggle actuator, so it can be used where manual operation is expected, provided the panel layout allows comfortable access and the device is not being used as a high-frequency control switch beyond its intended protective role. For applications involving repeated operator cycling, designers often assess mechanical wear, actuator access, and whether a separate control device is more suitable for routine switching.
What should I consider when replacing a breaker in an older panel with IAGN11-1REC4-39415-15?
When replacing an older breaker with IAGN11-1REC4-39415-15, the critical checks are panel cutout geometry, bezel depth, mounting hardware, pole count, and whether the original device had the same voltage class and trip behavior. Older installations may also have aging buswork or wiring insulation that benefits from a full inspection before a modern replacement is installed.
Is IAGN11-1REC4-39415-15 appropriate for systems that may see vibration or shock?
IAGN11-1REC4-39415-15 can be used in equipment exposed to vibration if the panel mounting, terminal retention, and conductor support are designed accordingly. In vibration-prone environments, engineers generally verify that the breaker remains secure in the panel, that terminal connections will not loosen over time, and that the toggle cannot be inadvertently operated by adjacent mechanical motion.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


IAGN11-1REC4-39415-15

Sensata-Airpax

CIR BRKR MAG-HYDR LEVER

In Stock: 918

Submit RFQ