Choose your country or region.

Image may be representation.
See specs for product details.

IAGN1-1REG4-41F-5.00

In Stock 2127 pcs Reference Price(In US Dollars)
3+
$116.2583
Manufacturer Part Number:
IAGN1-1REG4-41F-5.00
Manufacturer / Brand
Sensata-Airpax
Part of Description:
CIR BRKR MAG-HYDR LEVER
Datasheets:
IAGN1-1REG4-41F-5.00.pdf
Lead Free Status / RoHS Status:
RoHS Compliant
Stock Condition:
New original, 2127 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number IAGN1-1REG4-41F-5.00
Manufacturer / Brand Sensata-Airpax
Stock Quantity 2127 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIR BRKR MAG-HYDR LEVER
Lead Free Status / RoHS Status: RoHS Compliant
Voltage Rating - DC 80 V
Voltage Rating - AC 250 V
Series IAG
Package Bulk
Number of Poles 1
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 5A
Breaker Type Magnetic (Hydraulic Delay)
Base Product Number IAGN1-1REG4
Actuator Type Toggle

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can I use IAGN1-1REG4-41F-5.00 on a power supply or motor load with high startup inrush?
IAGN1-1REG4-41F-5.00 uses a magnetic (hydraulic delay) trip characteristic, so it is generally a better fit than a fast-acting breaker for loads with short inrush events such as switch-mode power supplies, transformers, and small motors. The key check is not only the 5 A nominal rating, but whether the load’s peak current and duration stay within the breaker’s delay window under worst-case temperature. If the inrush is repeated frequently, lasts too long, or the enclosure runs hot, nuisance trips can still occur. For design-in, validate the actual startup waveform on the final hardware rather than relying on the steady-state current alone.
Is IAGN1-1REG4-41F-5.00 suitable for DC battery or UPS circuits, and what limits should I verify first?
IAGN1-1REG4-41F-5.00 is rated for up to 80 V DC, but DC interruption is more demanding than AC because the arc is harder to extinguish. Before using it on a battery bus, UPS output, or other DC distribution point, verify the operating voltage, available fault current, and any inductive or regenerative energy in the load path. If the system can source very high fault current, add upstream protection and confirm the breaker’s interruption performance in the actual application. For inductive DC loads, suppression and wiring layout can materially change how the breaker behaves in service.
Can I replace a thermal breaker with IAGN1-1REG4-41F-5.00 in an existing panel without changing the rest of the design?
IAGN1-1REG4-41F-5.00 can be a practical replacement when the original design suffers nuisance trips from short overloads or startup surges, but the trip behavior will not match a thermal breaker exactly. Magnetic-hydraulic devices respond differently to overload timing, so slow overloads, pulse loads, and ambient temperature effects can produce different results. Before changing over, confirm the panel cutout, actuator style, mounting arrangement, terminal style, and required wiring clearance. If the legacy design depended on the original breaker’s slower thermal response, test the replacement on the real load profile and hottest expected operating condition.
How do I choose between IAGN1-1REG4-41F-5.00 and substitutes like IUGN6-1-62-30.0 or IAGN6-1-61-5.00?
IAGN1-1REG4-41F-5.00 should only be replaced with IUGN6-1-62-30.0, IAGN6-1-61-5.00, or another candidate after checking more than the current rating. Parts that look similar can still differ in actuator geometry, panel footprint, terminal arrangement, trip curve, and agency approvals. For a retrofit, compare the mechanical outline, wire termination method, and AC/DC rating, because a close electrical match may still be an awkward mechanical fit or a different protection profile. The safest approach is a side-by-side comparison against the manufacturer drawings and a validation test on the final load.
Is IAGN1-1REG4-41F-5.00 a good choice for industrial equipment running continuously in a warm enclosure?
IAGN1-1REG4-41F-5.00 can be used in industrial enclosures, but ambient temperature and heat buildup should be checked early in the design. Magnetic-hydraulic breakers can shift their trip behavior as the enclosure temperature rises, especially when the breaker is mounted near power electronics or other heat sources. If the circuit runs near 5 A for long periods, leave margin for cabinet temperature rise, wiring losses, and any concurrent loads. For long-term reliability, confirm operation at the highest expected ambient temperature, with the final panel orientation, wiring bundle, and ventilation scheme.
Can I use IAGN1-1REG4-41F-5.00 as the main disconnect for equipment, or only as branch protection?
IAGN1-1REG4-41F-5.00 is a protective circuit breaker and can provide local manual isolation in some systems, but it should not be assumed to replace a dedicated disconnect in every installation. If the equipment requires lockout/tagout, visible isolation, or simultaneous disconnection of multiple conductors, a single-pole breaker may not meet the full functional need by itself. In AC systems, a single-pole device also leaves the other conductor energized unless the overall architecture addresses that elsewhere. Review the applicable safety standard and the complete wiring topology before using IAGN1-1REG4-41F-5.00 as the only means of isolation.
What should I consider when using IAGN1-1REG4-41F-5.00 in a panel that sees vibration or frequent operator handling?
IAGN1-1REG4-41F-5.00 uses a toggle actuator, so panel location, wiring support, and mechanical retention matter in vibration-prone equipment. Confirm that the mounting arrangement does not place side load on the breaker body or terminals, and keep the wiring secured so harness movement does not transfer stress to the device. If operators will access the panel often, make sure the toggle remains easy to reach without accidental actuation or reset after a trip. In field equipment, it is also common to add labeling or a guard if there is a risk of unintended operation.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


IAGN1-1REG4-41F-5.00

Sensata-Airpax

CIR BRKR MAG-HYDR LEVER

In Stock: 2127

Submit RFQ