Choose your country or region.

Image may be representation.
See specs for product details.

TA45-ABFYHJ01C0-AZM02

Manufacturer Part Number:
TA45-ABFYHJ01C0-AZM02
Manufacturer / Brand
SCHURTER Inc.
Part of Description:
TA45-2R SERIES CIRCUIT BREAKER
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 38341 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number TA45-ABFYHJ01C0-AZM02
Manufacturer / Brand SCHURTER Inc.
Stock Quantity 38341 pcs Stock
Category Circuit Protection > Circuit Breakers
Description TA45-2R SERIES CIRCUIT BREAKER
Lead Free Status / RoHS Status: ROHS3 Compliant
Voltage Rating - DC 60 V
Voltage Rating - AC 240 V
Series TA45-2R
Package Box
Number of Poles 2
Mounting Type Panel Mount, Snap-In
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 100mA
Breaker Type Thermal
Base Product Number TA45-ABFYH
Approval Agency CSA C22.2 No 235, IEC60934, GB17701, UL1077
Actuator Type Rocker

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can I use SCHURTER TA45-ABFYHJ01C0-AZM02 as a drop-in replacement for another panel-mount breaker with the same 100 mA rating?
SCHURTER TA45-ABFYHJ01C0-AZM02 can be considered for replacement only if the electrical ratings, pole count, actuator style, and panel cutout geometry match the existing design. Because it is a TA45-2R series thermal breaker with a snap-in panel mount and rocker actuator, the mechanical fit is often the first compatibility check. In practice, engineers should verify trip behavior, reset feel, terminal arrangement, and any required approvals for the end equipment before assuming interchangeability with another 100 mA device.
Is SCHURTER TA45-ABFYHJ01C0-AZM02 suitable for protecting low-power control electronics or instrumentation circuits?
SCHURTER TA45-ABFYHJ01C0-AZM02 is suited to low-current protection where a 100 mA thermal breaker and manual reset behavior are acceptable. It is commonly evaluated for control circuits, small instrumentation branches, and compact equipment power paths. For sensitive electronics, designers should confirm that the thermal trip profile will not nuisance-trip during inrush or normal startup transients, since thermal devices respond to current over time rather than instantaneous fault spikes alone.
What should I check before using SCHURTER TA45-ABFYHJ01C0-AZM02 in a 240 VAC panel?
For SCHURTER TA45-ABFYHJ01C0-AZM02 in a 240 VAC application, confirm that the installation category, available fault current, and wiring method are consistent with the breaker’s intended use. Even when the nominal voltage rating is compatible, enclosure spacing, creepage/clearance, and upstream protection still need to be validated in the final assembly. Engineers also typically review whether the breaker is being used as supplemental protection within the equipment rather than as the only protective device.
Can SCHURTER TA45-ABFYHJ01C0-AZM02 be used on 60 VDC systems without issues?
SCHURTER TA45-ABFYHJ01C0-AZM02 is rated for 60 VDC, so it can be applied in DC systems within that limit if the application meets the rest of the design assumptions. In DC use, interruption is generally more demanding than AC, so the conductor size, fault energy, and upstream source impedance should be checked carefully. If the circuit can deliver high short-circuit current, the overall protective coordination needs to be reviewed rather than relying on the nominal DC voltage rating alone.
Is the snap-in panel mount of SCHURTER TA45-ABFYHJ01C0-AZM02 appropriate for equipment exposed to vibration?
SCHURTER TA45-ABFYHJ01C0-AZM02 uses a panel-mount, snap-in arrangement, which is convenient for fast assembly but should still be evaluated against vibration and shock requirements of the final product. In equipment with sustained mechanical stress, the panel thickness, cutout tolerances, retention force, and cable strain relief can influence long-term stability. Many designers also verify that the breaker body is not carrying unintended cable loads from the wiring harness.
How do I decide whether SCHURTER TA45-ABFYHJ01C0-AZM02 is better than a fuse for my design?
SCHURTER TA45-ABFYHJ01C0-AZM02 is a resettable protective device, so it is often preferred where field recovery and repeated use matter more than one-time sacrificial protection. Compared with a fuse, it avoids replacement after a trip, which can simplify maintenance in serviceable equipment. However, the trip curve is thermal and the breaker may reset into an unresolved fault if the underlying problem is not corrected, so designers often pair it with fault analysis and upstream current limitation.
What are the practical differences if I replace a fuse with SCHURTER TA45-ABFYHJ01C0-AZM02?
Replacing a fuse with SCHURTER TA45-ABFYHJ01C0-AZM02 changes both behavior and maintenance workflow. A fuse typically opens faster under severe faults, while this thermal breaker provides manual reset and repeated operation. Engineers should review startup inrush, fault clearing requirements, coordination with power supplies, and the desired service procedure, because the panel-accessible reset feature can be useful in the field but may not match the protection profile of the original fuse.
Does SCHURTER TA45-ABFYHJ01C0-AZM02 work well for products that need a front-panel user reset?
SCHURTER TA45-ABFYHJ01C0-AZM02 is a good fit when the design calls for a front-panel resettable protective control. The rocker actuator lets the user identify and reset the protected branch directly from the enclosure face. When used in customer-facing equipment, designers usually confirm that the actuator labeling, accessibility, and reset state are clear enough to prevent repeated cycling into an unresolved overload condition.
Can SCHURTER TA45-ABFYHJ01C0-AZM02 be used in equipment with frequent inrush current?
SCHURTER TA45-ABFYHJ01C0-AZM02 may work in some inrush-heavy designs, but thermal breakers can trip if the startup profile is too long or too repetitive. The relevant check is not just steady-state load current; it is the combination of inrush magnitude, duration, ambient temperature, and duty cycle. If the load includes capacitors, motors, lamps, or DC-DC converters, designers often validate the breaker by testing the actual startup waveform in the final system.
What replacement options should I compare against SCHURTER TA45-ABFYHJ01C0-AZM02 if I need the same front-panel style?
When evaluating alternatives to SCHURTER TA45-ABFYHJ01C0-AZM02, engineers usually compare similar panel-mount thermal circuit breakers from brands such as E-T-A, Carling Technologies, Sensata/Airpax, and other SCHURTER variants. The main differences to check are cutout dimensions, handle geometry, trip characteristics, reset behavior, and certification coverage. A direct substitute is rarely guaranteed by current rating alone, so the mechanical and regulatory match should be verified before redesigning the panel.
Is SCHURTER TA45-ABFYHJ01C0-AZM02 appropriate for industrial equipment that runs continuously?
SCHURTER TA45-ABFYHJ01C0-AZM02 can be used in continuously operating industrial equipment when the protected branch current stays within the intended thermal operating range and the ambient temperature is controlled. Thermal breakers are influenced by enclosure heat buildup, adjacent components, and ventilation, so a device that looks suitable on paper can behave differently in a dense cabinet. For long-duty applications, engineers often validate performance at worst-case ambient and consider derating margins.
What should I verify if I want to use SCHURTER TA45-ABFYHJ01C0-AZM02 in a safety-related circuit?
If SCHURTER TA45-ABFYHJ01C0-AZM02 is being considered for a safety-related circuit, confirm how it fits into the overall protection architecture, because it is certified as a supplemental protector under UL1077 rather than being a complete substitute for all branch-protection schemes. Designers usually review the end standard, fault level, enclosure construction, and required coordination with other protective devices. The final compliance decision depends on the system-level safety concept, not only on the breaker itself.
How should I think about conductor sizing when using SCHURTER TA45-ABFYHJ01C0-AZM02 at 100 mA?
With SCHURTER TA45-ABFYHJ01C0-AZM02, conductor sizing should be based on the circuit’s protective coordination and installation method rather than the 100 mA rating alone. The wire must tolerate normal load current, ambient heating, and any permissible overload until the breaker operates. In compact assemblies, terminal temperature rise and harness layout also matter, so designers commonly validate the wire gauge against the full installation environment.
Does the two-pole design of SCHURTER TA45-ABFYHJ01C0-AZM02 matter in single-line or DC applications?
Yes, the two-pole configuration of SCHURTER TA45-ABFYHJ01C0-AZM02 affects how the circuit is isolated and interrupted. In AC systems, a two-pole breaker can disconnect both conductors depending on the wiring scheme, while in DC systems it can provide more complete separation when used correctly. Engineers should confirm the intended conductor arrangement, polarity strategy, and safety isolation requirements before selecting the two-pole version over a single-pole alternative.
What are the main risks when redesigning a product around SCHURTER TA45-ABFYHJ01C0-AZM02?
The main redesign risks with SCHURTER TA45-ABFYHJ01C0-AZM02 are usually mechanical fit, thermal trip behavior, and compliance alignment. A panel cutout that is slightly different can force enclosure changes, and a different trip curve can alter startup reliability or nuisance-tripping behavior. Designers also need to confirm approvals, wiring access, and service procedure so the replacement does not create hidden changes in the user experience or certification scope.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


TA45-ABFYHJ01C0-AZM02

SCHURTER Inc.

TA45-2R SERIES CIRCUIT BREAKER

In Stock: 38341

SUBMIT RFQ