Choose your country or region.

Image may be representation.
See specs for product details.

TA45-ABFXS110C0-AZM01

Manufacturer Part Number:
TA45-ABFXS110C0-AZM01
Manufacturer / Brand
SCHURTER Inc.
Part of Description:
TA45-2R SERIES CIRCUIT BREAKER
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 37799 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number TA45-ABFXS110C0-AZM01
Manufacturer / Brand SCHURTER Inc.
Stock Quantity 37799 pcs Stock
Category Circuit Protection > Circuit Breakers
Description TA45-2R SERIES CIRCUIT BREAKER
Lead Free Status / RoHS Status: ROHS3 Compliant
Voltage Rating - DC 60 V
Voltage Rating - AC 240 V
Series TA45-2R
Package Box
Number of Poles 2
Mounting Type Panel Mount, Snap-In
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 11A
Breaker Type Thermal
Base Product Number TA45-ABFXS
Approval Agency CSA C22.2 No 235, IEC60934, GB17701, UL1077
Actuator Type Rocker

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can TA45-ABFXS110C0-AZM01 be used on a circuit with high available fault current?
TA45-ABFXS110C0-AZM01 is a supplementary thermal breaker, so the surrounding protection scheme still needs to limit fault energy to a level the assembly can safely handle. In installations with high available short-circuit current, engineers typically add upstream fusing or branch protection and then verify coordination using the final supply impedance, wiring length, and protective device stack-up. For TA45-ABFXS110C0-AZM01, the final acceptance check should be done on the real system rather than on the breaker rating alone.
Is TA45-ABFXS110C0-AZM01 suitable for mixed AC/DC equipment, or should I split the protection scheme?
TA45-ABFXS110C0-AZM01 is rated for 240 V AC and 60 V DC, so it can fit either domain if the actual operating voltage and fault conditions stay within those limits. In mixed-power equipment, it is common to separate AC and DC branches so each load type can be validated against its own transient behavior and interruption stress. For TA45-ABFXS110C0-AZM01, confirm the wiring, load profile, and any DC fault-clearing requirements before using the same protection approach for both rails.
How do I reduce nuisance tripping with TA45-ABFXS110C0-AZM01 in a hot or compact panel?
TA45-ABFXS110C0-AZM01 is a thermal device, so local temperature has a direct effect on its trip behavior. High ambient temperature, dense wiring, adjacent power components, and poor airflow can reduce margin and make the breaker trip earlier than expected. A practical design-in approach is to evaluate TA45-ABFXS110C0-AZM01 at the worst-case enclosure temperature, not just at room temperature, and to keep it away from heat sources such as transformers, resistors, or high-loss power supplies.
Can TA45-ABFXS110C0-AZM01 handle motor, solenoid, or power-supply inrush currents?
TA45-ABFXS110C0-AZM01 may ride through brief inrush events, but repeated startup surges can still lead to nuisance trips because the mechanism responds to heat over time. This matters with motors, transformers, solenoids, LED drivers, and switch-mode power supplies that draw a large pulse at turn-on or after a short power interruption. The usual design step is to compare the real inrush waveform and restart frequency against the breaker’s time-current behavior, then test TA45-ABFXS110C0-AZM01 at cold and hot conditions before freezing the design.
How should the 2 poles on TA45-ABFXS110C0-AZM01 be used in an actual wiring diagram?
TA45-ABFXS110C0-AZM01 is a 2-pole breaker, so it is commonly used to interrupt both supply conductors in AC systems or to isolate both conductors in a two-wire DC architecture when the compliance scheme requires it. Do not assume the poles can be paralleled for extra current unless SCHURTER explicitly allows that configuration in the application notes. For TA45-ABFXS110C0-AZM01, the final wiring choice should follow the schematic, conductor identification, and local isolation rules for the end equipment.
Can TA45-ABFXS110C0-AZM01 replace an E-T-A, Carling, or Eaton rocker breaker one-for-one?
TA45-ABFXS110C0-AZM01 is not a guaranteed drop-in substitute just because it is a rocker-style breaker with similar electrical ratings. A true replacement check needs the panel cutout, panel thickness, bezel geometry, depth behind the panel, terminal arrangement, pole count, and trip indication to match the existing design. When migrating from an E-T-A, Carling, or Eaton part, compare TA45-ABFXS110C0-AZM01 against the mechanical drawing and agency files, then prototype the fit before treating it as interchangeable.
Is TA45-ABFXS110C0-AZM01 appropriate as the main disconnect or emergency-stop device?
TA45-ABFXS110C0-AZM01 is intended as a thermal circuit breaker, not as a dedicated emergency-stop device or a full maintenance isolator. In many machines, it is used for branch protection while a separate disconnect switch, safety relay, or E-stop circuit handles lockout, visible isolation, or functional safety requirements. If the application needs padlocking, certified isolation, or a control-reliable stop function, TA45-ABFXS110C0-AZM01 should be paired with a device specifically rated for that role.
What long-term reliability checks make sense for TA45-ABFXS110C0-AZM01 in industrial equipment?
For TA45-ABFXS110C0-AZM01, long-term checks usually focus on trip consistency, actuator feel, panel retention, terminal tightness, contamination, and the effect of vibration or thermal cycling over time. In dusty or oily environments, the handle and surrounding panel can change feel before an electrical problem is obvious, so scheduled functional testing is a practical way to catch drift early. If TA45-ABFXS110C0-AZM01 is reset frequently, it is also worth reviewing the root cause of the overload rather than relying on repeated reset cycles.
Since TA45-ABFXS110C0-AZM01 has no illumination, how can I give operators clear trip status?
TA45-ABFXS110C0-AZM01 does not include built-in illumination, so panel status usually has to be provided by a separate pilot lamp, HMI message, or control input that monitors downstream power. If the maintenance workflow depends on a lit breaker handle, the panel design should add an external indication path instead of assuming the rocker itself will provide visibility in low-light conditions. For TA45-ABFXS110C0-AZM01, that external status logic can also reduce confusion during troubleshooting and service.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


TA45-ABFXS110C0-AZM01

SCHURTER Inc.

TA45-2R SERIES CIRCUIT BREAKER

In Stock: 37799

Submit RFQ