Choose your country or region.

Image may be representation.
See specs for product details.

TA45-ABFRL070C0-AZM12

Manufacturer Part Number:
TA45-ABFRL070C0-AZM12
Manufacturer / Brand
SCHURTER Inc.
Part of Description:
TA45-2R SERIES CIRCUIT BREAKER
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 49756 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number TA45-ABFRL070C0-AZM12
Manufacturer / Brand SCHURTER Inc.
Stock Quantity 49756 pcs Stock
Category Circuit Protection > Circuit Breakers
Description TA45-2R SERIES CIRCUIT BREAKER
Lead Free Status / RoHS Status: ROHS3 Compliant
Voltage Rating - DC 60 V
Voltage Rating - AC 240 V
Series TA45-2R
Package Box
Number of Poles 2
Mounting Type Panel Mount, Snap-In
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 7A
Breaker Type Thermal
Base Product Number TA45-ABFRL
Approval Agency CSA C22.2 No 235, IEC60934, GB17701, UL1077
Actuator Type Rocker

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can I use SCHURTER TA45-ABFRL070C0-AZM12 as a direct replacement for another 2-pole panel-mount breaker in an existing enclosure?
SCHURTER TA45-ABFRL070C0-AZM12 can be used as a replacement when the panel cutout, snap-in retention geometry, actuator style, and pole count match the original device. In addition to the mechanical fit, check the trip behavior and reset feel of the TA45-ABFRL070C0-AZM12, since thermal breakers from different series can respond differently under overload and ambient temperature. If the original part used a different current rating, voltage rating, or approved standard set, the TA45-ABFRL070C0-AZM12 should be requalified in the final assembly before release.
Is SCHURTER TA45-ABFRL070C0-AZM12 suitable for replacing a fuse in a design that needs user reset after overload?
SCHURTER TA45-ABFRL070C0-AZM12 is a practical option when the goal is to avoid fuse replacement during service and provide a manual reset path after a thermal trip. The TA45-ABFRL070C0-AZM12 is thermal, so its response is slower than electronic protection devices and it is typically better for overload protection than for very fast short-circuit interruption. If the circuit has high inrush currents or sensitive semiconductors, coordination with upstream or downstream protection should be reviewed before replacing a fuse with the TA45-ABFRL070C0-AZM12.
Can SCHURTER TA45-ABFRL070C0-AZM12 be used in a mains-powered appliance with both AC and DC inputs?
SCHURTER TA45-ABFRL070C0-AZM12 is rated for 240 V AC and 60 V DC, so it can fit designs that may operate from either domain as long as the actual operating voltage stays within those limits. For dual-input equipment, verify the worst-case voltage across the breaker in every operating mode, including transient conditions and abnormal supply states. The TA45-ABFRL070C0-AZM12 should also be checked for the required interrupting performance in the specific application, since voltage rating alone does not guarantee suitability for every fault scenario.
What should I check when using SCHURTER TA45-ABFRL070C0-AZM12 in a design with high inrush current?
SCHURTER TA45-ABFRL070C0-AZM12 is a thermal breaker, so repetitive inrush current can affect whether the device nuisance-trips or runs warmer than expected. In motor drives, transformer primaries, large capacitive loads, and switched-mode power supplies, compare the inrush waveform against the breaker’s thermal tolerance and the expected ambient temperature. If the load has a short, high peak current but normal steady-state current is well below 7 A, the TA45-ABFRL070C0-AZM12 may still require a margin study or soft-start circuitry.
Is SCHURTER TA45-ABFRL070C0-AZM12 appropriate for a sealed industrial panel exposed to elevated ambient temperature?
SCHURTER TA45-ABFRL070C0-AZM12 can be used in industrial panels, but thermal breakers are sensitive to ambient temperature because the trip point shifts with heat. In a sealed enclosure with limited airflow, the TA45-ABFRL070C0-AZM12 may trip earlier than expected if nearby components raise local temperature. For long-term industrial use, verify derating in the actual enclosure, especially when the breaker is mounted near power supplies, heatsinks, or other heat-producing parts.
How do I confirm the panel cutout and mounting method for SCHURTER TA45-ABFRL070C0-AZM12?
SCHURTER TA45-ABFRL070C0-AZM12 uses a panel-mount, snap-in arrangement, so the panel thickness, cutout shape, and retention force need to match the product’s mechanical interface. Before tooling the enclosure, compare the breaker’s datasheet drawing with the panel stack-up, gasket requirements if any, and assembly access from the rear side. The TA45-ABFRL070C0-AZM12 should be checked for fit after surface finishes or powder coating are applied, since small dimensional changes can affect snap-in retention.
Can SCHURTER TA45-ABFRL070C0-AZM12 be used on a PCB-mounted power entry module design?
SCHURTER TA45-ABFRL070C0-AZM12 is a panel-mount breaker rather than a PCB-mounted protection component, so it is better suited to front-panel or chassis-mounted power entry designs. If the product architecture requires PCB integration, the TA45-ABFRL070C0-AZM12 would typically need wiring or a harness between the breaker and the board, which adds assembly steps and should be assessed for creepage, strain relief, and service access. For fully board-integrated protection, a PCB-mounted breaker or fuse solution may be more practical.
What are the design implications of using SCHURTER TA45-ABFRL070C0-AZM12 as a 2-pole breaker?
SCHURTER TA45-ABFRL070C0-AZM12 is a 2-pole device, which means both conductors can be interrupted together in a suitably designed circuit. This is helpful in systems where both lines must be isolated for maintenance, or where a paired conductor arrangement is used. When integrating the TA45-ABFRL070C0-AZM12, confirm that the wiring scheme, neutral/line assignment, and safety requirements match the two-pole switching behavior and that the installation complies with the target market’s wiring practice.
How does SCHURTER TA45-ABFRL070C0-AZM12 compare with a 7 A resettable fuse or PTC for overload protection?
SCHURTER TA45-ABFRL070C0-AZM12 provides manual reset behavior and a defined mechanical interface, while a PTC resettable fuse is typically smaller and more board-oriented. Compared with a PTC, the TA45-ABFRL070C0-AZM12 usually offers clearer service indication and a more robust panel-user interaction, but it also requires panel space and a front-access mounting strategy. If the circuit needs very compact overcurrent protection or automatic recovery after minor faults, a PTC may be a better fit; if serviceable front-panel reset is desired, the TA45-ABFRL070C0-AZM12 is more aligned.
What replacement part should I look at if I need a SCHURTER TA45-ABFRL070C0-AZM12 alternative from another manufacturer?
When sourcing an alternative to SCHURTER TA45-ABFRL070C0-AZM12, match the electrical rating, number of poles, mounting style, and panel cutout first, then compare trip curves and approvals. Cross-references from other brands can differ in actuation force, tolerance to ambient temperature, and reset behavior even when the current rating appears similar. For a safe substitution, the candidate should be validated in the same enclosure with the same wiring and load profile as the TA45-ABFRL070C0-AZM12.
Is SCHURTER TA45-ABFRL070C0-AZM12 suitable for equipment that requires UL and IEC recognition?
SCHURTER TA45-ABFRL070C0-AZM12 carries approvals including CSA C22.2 No 235, IEC60934, GB17701, and UL1077, which supports use in equipment designed around those standards. The final suitability still depends on how the breaker is applied in the end product, including circuit role, installation method, and enclosure conditions. When using the TA45-ABFRL070C0-AZM12 in a certified product, the complete system documentation should show that the breaker’s use matches the intended safety architecture.
What should I consider if the load connected to SCHURTER TA45-ABFRL070C0-AZM12 runs near 7 A continuously?
SCHURTER TA45-ABFRL070C0-AZM12 is rated at 7 A, but continuous operation close to that level can interact with ambient temperature, enclosure heat, and conductor losses. In practice, a design running near the nominal current should be evaluated for margin rather than treated as a fixed threshold. For the TA45-ABFRL070C0-AZM12, confirm the expected steady-state current, peak current, and worst-case enclosure temperature so that nuisance tripping is unlikely during long-duration operation.
Can SCHURTER TA45-ABFRL070C0-AZM12 be used in products sold into multiple regions?
SCHURTER TA45-ABFRL070C0-AZM12 supports a range of common regulatory contexts through its listed approvals, which can simplify multi-region product planning. Even so, regional acceptance depends on the complete end product, the wiring configuration, and the final compliance file. For a global platform, the TA45-ABFRL070C0-AZM12 should be reviewed alongside the enclosure, conductors, and any complementary protection devices so the same platform can meet the required local rules.
Does the absence of illumination on SCHURTER TA45-ABFRL070C0-AZM12 affect serviceability in low-light equipment?
SCHURTER TA45-ABFRL070C0-AZM12 has no illumination, so fault indication depends on the actuator position and the operator’s access to the panel. In equipment serviced in dim environments, this can be offset by labeling, external status indicators, or a maintenance procedure that confirms breaker state before restart. The TA45-ABFRL070C0-AZM12 is still workable in such designs, but the front-panel human factors should be handled elsewhere in the interface.
What reliability checks are recommended before using SCHURTER TA45-ABFRL070C0-AZM12 in long-life industrial equipment?
For SCHURTER TA45-ABFRL070C0-AZM12, the main reliability checks are thermal cycling, vibration or shock exposure at the panel, repeated manual actuation, and performance at the highest expected ambient temperature. Since it is a panel-mounted thermal breaker, the connector wiring, retention in the snap-in panel, and the surrounding thermal environment all contribute to long-term behavior. A qualification plan for the TA45-ABFRL070C0-AZM12 should therefore include the actual enclosure, not only bench testing of the standalone part.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


TA45-ABFRL070C0-AZM12

SCHURTER Inc.

TA45-2R SERIES CIRCUIT BREAKER

In Stock: 49756

SUBMIT RFQ