Choose your country or region.

Image may be representation.
See specs for product details.

TA45-ABFGT060C0-AZM11

Manufacturer Part Number:
TA45-ABFGT060C0-AZM11
Manufacturer / Brand
SCHURTER Inc.
Part of Description:
TA45-2R SERIES CIRCUIT BREAKER
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 34930 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number TA45-ABFGT060C0-AZM11
Manufacturer / Brand SCHURTER Inc.
Stock Quantity 34930 pcs Stock
Category Circuit Protection > Circuit Breakers
Description TA45-2R SERIES CIRCUIT BREAKER
Lead Free Status / RoHS Status: ROHS3 Compliant
Voltage Rating - DC 60 V
Voltage Rating - AC 240 V
Series TA45-2R
Package Box
Number of Poles 2
Mounting Type Panel Mount, Snap-In
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 6A
Breaker Type Thermal
Base Product Number TA45-ABFGT
Approval Agency CSA C22.2 No 235, IEC60934, GB17701, UL1077
Actuator Type Rocker

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can TA45-ABFGT060C0-AZM11 be used as the only protection device on a 240 VAC input?
TA45-ABFGT060C0-AZM11 is a UL1077 supplementary protector, so in many designs it is used alongside upstream branch protection or a fuse rather than as the sole fault-clearing device. For a mains-fed product, verify available short-circuit current, coordination with the upstream protective device, and whether your safety standard requires branch-circuit protection in addition to the breaker. This is especially relevant when the equipment can be connected to high-fault-current building wiring.
Is TA45-ABFGT060C0-AZM11 suitable for switching power supplies, LED drivers, or other loads with high inrush current?
TA45-ABFGT060C0-AZM11 can work with SMPS or LED loads, but thermal breakers are sensitive to repeated inrush and can nuisance-trip if the start-up surge is large or the ambient temperature is elevated. A good design practice is to compare the cold-start and hot-restart current profile against the breaker trip behavior, then test brownout recovery as well. If the load has significant capacitance, an inrush limiter, soft-start circuit, or a different current rating may be needed.
How should I evaluate TA45-ABFGT060C0-AZM11 for 48 V or 60 V DC battery-powered equipment?
TA45-ABFGT060C0-AZM11 is rated for up to 60 V DC, but DC protection depends heavily on fault current, inductive energy, and the source’s discharge capability. Battery systems can deliver very high short-circuit current, so the breaker should be coordinated with upstream fusing or current limiting rather than assumed to clear every fault by itself. For inductive loads, confirm interruption behavior under worst-case DC arc conditions.
What panel cutout and mechanical checks should I make before replacing another rocker breaker with TA45-ABFGT060C0-AZM11?
TA45-ABFGT060C0-AZM11 is a panel-mount, snap-in rocker breaker, so the panel thickness, cutout geometry, and rear clearance need to match the existing installation. When retrofitting, check not only the visible bezel but also the latch engagement, actuator travel, terminal orientation, and harness bend radius behind the panel. A direct replacement is most reliable when the cutout and mounting tolerances are verified on production panels, not just on a sample enclosure.
Is TA45-ABFGT060C0-AZM11 a good choice for hot industrial enclosures or equipment with limited ventilation?
TA45-ABFGT060C0-AZM11 is a thermal device, so its trip behavior shifts with ambient temperature and self-heating from adjacent components. In a sealed cabinet or near a heat source, the effective current margin can narrow and the breaker may operate sooner than expected during sustained load. It is common to validate performance at the highest cabinet temperature and after thermal soak, then derate if the measured margin is small.
How does the 2-pole design of TA45-ABFGT060C0-AZM11 affect wiring and system isolation?
TA45-ABFGT060C0-AZM11 opens both poles, which is useful when you want simultaneous disconnection of line and neutral or positive and negative conductors. This can simplify service isolation, but it also means the breaker must be wired so both poles see the intended circuit path and voltage stress. In DC systems, confirm polarity, pole assignment, and any local rules for all-pole disconnection before freezing the schematic.
Can TA45-ABFGT060C0-AZM11 replace a fuse or resettable PTC in an existing design?
TA45-ABFGT060C0-AZM11 can replace a fuse or PTC when the design benefits from manual reset and clear visual status, but its trip behavior is different from a fast-acting fuse. If semiconductor protection depends on very fast fault interruption, many designs keep a fuse or electronic current limit upstream and use the breaker for branch-level protection. Compared with a PTC, the breaker usually has lower steady-state voltage drop and avoids the high resistance increase that PTCs develop after heating.
What are the practical differences between TA45-ABFGT060C0-AZM11 and a magnetic circuit breaker for replacement decisions?
TA45-ABFGT060C0-AZM11 uses thermal trip behavior, which is well suited to overload protection with a more time-dependent response, while magnetic breakers respond more quickly to high fault currents. If your existing design depends on a very fast trip for short-circuit coordination, a direct thermal-to-magnetic swap can change nuisance-trip behavior and fault clearance timing. For a redesign, compare the full trip curve, not just the current rating printed on the front.
What reliability checks make sense for long-term use of TA45-ABFGT060C0-AZM11 in equipment that is reset frequently?
For TA45-ABFGT060C0-AZM11, long-term validation usually includes cycle testing, contact resistance checks, and mechanical feel after repeated manual resets. Vibration, panel flex, dust ingress, and connector strain can all influence whether the actuator moves consistently and whether the pole contacts remain stable over time. In equipment that sees frequent field resets, periodic inspection of wiring terminations and panel fit can help keep behavior repeatable.
If I need a different current rating or a similar footprint, what should I compare before moving away from TA45-ABFGT060C0-AZM11?
When selecting another part in the SCHURTER TA45-2R family or a substitute from another vendor, start with panel cutout, pole count, reset style, approvals, and trip characteristics rather than current rating alone. TA45-ABFGT060C0-AZM11 may share a visual form factor with other variants, but the usable replacement still depends on the load profile, ambient temperature, and agency requirements such as UL1077 or IEC60934. If the new part has a different actuator marking or depth behind the panel, the enclosure layout may need a mechanical update.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


TA45-ABFGT060C0-AZM11

SCHURTER Inc.

TA45-2R SERIES CIRCUIT BREAKER

In Stock: 34930

SUBMIT RFQ