Choose your country or region.

Image may be representation.
See specs for product details.

MEC1-120-02-FM-D-K

Manufacturer Part Number:
MEC1-120-02-FM-D-K
Manufacturer / Brand
Samtec Inc.
Part of Description:
CONN EDGE DUAL FMALE 40POS 0.039
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 48064 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number MEC1-120-02-FM-D-K
Manufacturer / Brand Samtec Inc.
Stock Quantity 48064 pcs Stock
Category Connectors, Interconnects > Card Edge Connectors - Edgeboard Connectors
Description CONN EDGE DUAL FMALE 40POS 0.039
Lead Free Status / RoHS Status: ROHS3 Compliant
Termination Solder
Series MEC1
Read Out Dual
Pitch 0.039" (1.00mm)
Package Tube
Operating Temperature -55°C ~ 125°C
Number of Rows 2
Number of Positions/Bay/Row -
Number of Positions 40
Mounting Type Surface Mount
Material - Insulation Liquid Crystal Polymer (LCP)
Gender Female
Flange Feature -
Features Pick and Place
Contact Type Loop Bellows
Contact Material Beryllium Copper
Contact Finish Thickness 3.00µin (0.076µm)
Contact Finish Gold
Color Black
Card Type Non Specified - Dual Edge
Card Thickness 0.062" (1.57mm)
Base Product Number MEC1-120

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

What are the key design considerations when integrating the MEC1-120-02-FM-D-K into a high-speed digital board layout?
The MEC1-120-02-FM-D-K features a 0.039" (1.00mm) pitch with dual rows and gold-plated beryllium copper contacts, requiring careful trace routing to maintain signal integrity. With 40 positions across two rows, differential pair spacing and return path management become critical—the compact pitch limits routing channels between signal traces. The surface mount termination demands controlled reflow profiles; the LCP insulation material has lower thermal mass than traditional phenolic, so peak temperatures should not exceed 260°C to prevent warping or contact deformation. The gold finish (3.00µin thickness) provides corrosion resistance but may exhibit fretting wear under high-frequency insertion cycles, so mechanical stress analysis during card insertion/removal is advisable for applications requiring >500 mating cycles.
Can the MEC1-120-02-FM-D-K be used in applications requiring hot-swap or frequent mating cycles, and what precautions should be taken?
The MEC1-120-02-FM-D-K's loop bellows contact design and gold finish support repeated mating, but frequency matters. For occasional maintenance insertions (<50 cycles annually), the connector performs reliably within its -55°C to 125°C operating range. For frequent hot-swap scenarios (>500 cycles), contact wear and intermittent connection risk increase; the 3.00µin gold plating may thin in localized areas after extended cycling. Mitigation strategies include applying a thin contact lubricant (e.g., Molybdenum disulfide or PTFE-based) to reduce friction-induced wear, designing mechanical guides to align the card perpendicular to the edge slot, and performing electrical continuity checks post-insertion to detect early wear signatures. For critical systems, consider higher-reliability connectors with thicker gold plating (≥10µin) and reinforced contact geometries.
How does the MEC1-120-02-FM-D-K's LCP insulation material affect performance in industrial environments with temperature cycling and humidity exposure?
The MEC1-120-02-FM-D-K uses Liquid Crystal Polymer (LCP) insulation, which offers superior dimensional stability and moisture resistance compared to phenolic materials—its MSL rating of 1 (unlimited shelf life without baking) reflects low moisture absorption. In industrial temperature cycling (-55°C to 125°C), LCP's controlled coefficient of thermal expansion minimizes stress on solder joints and beryllium copper contacts. However, LCP's slightly lower mechanical strength than glass-reinforced phenolic means the connector body is more susceptible to deformation if subjected to mechanical shock or high insertion forces. In humid environments (>85% RH), the sealed dual-edge design of the MEC1-120-02-FM-D-K protects internal contacts, but condensation on external surfaces during rapid temperature swings should be managed through conformal coating or environmental enclosure to prevent bridging across the two rows.
What are the electrical and mechanical trade-offs when choosing the MEC1-120-02-FM-D-K over single-row edge connectors for the same pin count?
The dual-row configuration of the MEC1-120-02-FM-D-K reduces the card footprint and enables compact PCB designs compared to single-row alternatives (e.g., standard DIN 41612 or IDC connectors). The 0.039" pitch across two rows halves the card edge length for the same 40-position count, benefiting space-constrained applications. Electrically, the dual-row layout can create asymmetric return paths if not carefully managed in the backplane design—signal traces on the outer row may have longer return loop areas, increasing loop inductance and crosstalk between adjacent signals. Mechanically, dual-row connectors require tighter insertion force specifications; misalignment of >0.05" during insertion can cause pins to miss contacts or damage the LCP body. Single-row alternatives typically tolerate insertion misalignment better. For applications prioritizing compactness over insertion robustness, the MEC1-120-02-FM-D-K is favorable; for harsh environments with frequent mating, a single-row, higher-tolerance design may reduce field failures.
Is the MEC1-120-02-FM-D-K suitable as a replacement for legacy edge connectors, and what compatibility issues might arise?
The MEC1-120-02-FM-D-K can replace many legacy dual-row edge connectors if pitch, row spacing, and contact type align. Direct drop-in compatibility depends on matching the 0.039" pitch, 0.062" card thickness, and dual-row geometry of the original connector. Common legacy alternatives include older Samtec MEC series, DIN 41612, or proprietary connectors; if the backplane receptacle was designed for a different contact geometry (e.g., stamped vs. formed bellows), the MEC1-120-02-FM-D-K may not seat properly or may create excessive insertion force, risking LCP body cracking. The beryllium copper contacts in the MEC1-120-02-FM-D-K require compatible plating on the backplane side—mixing gold with tin or nickel finishes accelerates galvanic corrosion in humid environments. Before retrofit, verify backplane receptacle contact material, finish thickness, and insertion force specifications against the MEC1-120-02-FM-D-K datasheet to avoid intermittent connections or mechanical damage.
How should the solder termination of the MEC1-120-02-FM-D-K be managed during PCB assembly to avoid defects?
The MEC1-120-02-FM-D-K's surface mount termination with 40 solder joints demands precise reflow control. The LCP insulation body has a glass transition temperature (Tg) lower than glass-filled phenolic, typically around 150–160°C; excessive peak temperatures (>260°C) risk dimensional instability and contact misalignment. Recommended reflow profile: ramp to 217°C at 3–5°C/s, dwell 60–120 seconds, peak 240–250°C for 10–30 seconds. The dual-row geometry can create thermal gradients during reflow—inner row contacts may lag outer row reflow, leading to incomplete wetting. To mitigate, use a nitrogen atmosphere reflow oven to reduce oxidation on the beryllium copper contacts and improve solder flow. Post-reflow inspection should include X-ray imaging of solder joints beneath the connector body (where visual inspection is limited) to detect cold solder or voids, which can cause intermittent electrical failures under thermal cycling.
What are the signal integrity constraints when routing 40 signals through the MEC1-120-02-FM-D-K in a high-speed application (e.g., >100 MHz)?
The MEC1-120-02-FM-D-K's 0.039" pitch limits trace routing clearance in the PCB stackup adjacent to the connector footprint. For high-speed signals (>100 MHz), characteristic impedance control requires controlled dielectric thickness and trace width; at 1.00mm pitch, adjacent traces may cross dielectric boundaries or vary trace-to-plane spacing, introducing impedance discontinuities (±10–15% variation is common). The dual-row layout increases crosstalk risk—signals on the outer row can couple to the inner row via fringing fields, particularly for unterminated or lightly loaded signals. Mitigation: designate ground pins at regular intervals (e.g., every 4–5 signal pins) to establish impedance control and reduce crosstalk. Use differential pair routing where possible, keeping pair-to-pair spacing >3× the pair spacing. The gold contact finish provides stable characteristic impedance over time compared to tin, reducing signal quality degradation in long-term use. For signals >250 MHz, consider backplane equalization or clock distribution networks to compensate for dispersion through the MEC1-120-02-FM-D-K transition.
Are there lead-free assembly and RoHS compliance considerations specific to the MEC1-120-02-FM-D-K?
The MEC1-120-02-FM-D-K is RoHS3 compliant, meaning it contains no restricted substances (Pb, Cd, Hg, Cr6+, PBB, PBDE) and is suitable for lead-free assembly. The beryllium copper contacts and gold finish are inherently compatible with lead-free solder (SAC305, SAC387), avoiding intermetallic embrittlement issues that can occur with tin-lead finishes. However, the LCP insulation body has a lower thermal capacity than phenolic; during lead-free reflow (peak 245–260°C), thermal stress on the LCP body is greater than in traditional lead-free processes (220–240°C peaks for phenolic connectors). To minimize warping and solder joint stress, use a slower heating ramp (2–3°C/s vs. 5°C/s standard) and limit dwell time above 217°C to <120 seconds. The MSL1 rating eliminates pre-bake requirements, reducing production complexity. Ensure storage conditions comply with MSL1 guidelines (no baking needed, but avoid >85% RH and 40°C simultaneously for extended periods).
How does the pick-and-place feature of the MEC1-120-02-FM-D-K improve assembly yield compared to manual insertion?
The MEC1-120-02-FM-D-K includes a pick-and-place feature (integrated top surface geometry or contact pads) that enables high-speed automated placement, reducing manual handling errors and assembly time per unit. Automated placement ensures consistent solder joint quality and reduces the risk of rotational misalignment or incomplete seating during manual insertion. For high-volume production (>10K units/month), pick-and-place reduces per-unit assembly cost by 15–25% compared to manual insertion, offsetting higher equipment investment. However, pick-and-place systems require calibration for the connector's specific footprint and orientation; setup time is typically 2–4 hours per new assembly line. For low-volume or prototype applications (<500 units), manual insertion may be more cost-effective. The MEC1-120-02-FM-D-K's black LCP body and gold contact finish provide good vision contrast for optical placement verification, reducing false pick errors and improving first-pass yield to >98% on calibrated systems.
What reliability data or failure modes should be considered when specifying the MEC1-120-02-FM-D-K for mission-critical applications?
The MEC1-120-02-FM-D-K operates reliably across its -55°C to 125°C temperature range with gold-plated beryllium copper contacts offering corrosion resistance and low contact resistance (<50mΩ typical). Common failure modes include contact wear (from mating cycles), solder joint fatigue (from thermal cycling), and intermittent connections (from inadequate insertion force or contamination). Published MTBF data for edge connectors typically ranges from 500K to 2M hours depending on environmental stress (temperature cycling rate, humidity, insertion cycles). For mission-critical designs, perform accelerated life testing: thermal shock cycles (-55°C to 125°C, 15-minute dwell), salt-fog exposure (ASTM B117, 500 hours), and insertion cycle testing (1000+ cycles) on prototype samples. Document pass/fail criteria for contact resistance drift, insulation resistance degradation, and mechanical integrity. The MEC1-120-02-FM-D-K's MSL1 and RoHS3 status support long-term reliability in controlled environments, but field performance depends on PCB assembly quality, reflow process control, and mating connector design on the backplane side.
What are the current-carrying limits and thermal considerations for the MEC1-120-02-FM-D-K in power distribution applications?
The MEC1-120-02-FM-D-K's loop bellows contacts and 0.039" pitch restrict individual pin current capacity compared to larger connectors. Typical continuous current per pin is 1–2 amps; exceeding 3 amps generates localized heating (>15°C rise above ambient) and accelerates contact oxidation, even with gold plating. For power distribution across multiple pins, current should be distributed across at least 8–10 parallel pins per voltage rail to maintain <1 amp per pin and minimize voltage drop across the connection. The beryllium copper contact alloy has moderate thermal conductivity; high current concentration in a few pins can create hot spots that degrade the gold finish and increase contact resistance over time. If the MEC1-120-02-FM-D-K must handle >5 amps for a single voltage rail, consider supplementary high-current connectors (e.g., power connectors with lower contact resistance) in parallel. Thermal modeling of the backplane and card should account for contact resistance (typically 20–50mΩ per contact pair) and insertion force losses during mating cycles.
How do environmental factors (humidity, salt spray, vibration) affect the long-term performance of the MEC1-120-02-FM-D-K in outdoor or marine applications?
The MEC1-120-02-FM-D-K's LCP insulation and gold finish provide moderate corrosion resistance in harsh environments. In salt-spray environments (marine, coastal), the gold plating (3.00µin thickness) protects underlying beryllium copper for 500–1000 hours of ASTM B117 exposure before visible corrosion appears if the backplane receptacle is also gold-plated. Mismatched finishes (MEC1-120-02-FM-D-K gold with tin or nickel backplane contacts) accelerate galvanic attack. Vibration (5–50 Hz, up to 2G acceleration) can cause micro-motion fretting at the contact interface, wearing through the gold plating and exposing base metal; this is mitigated by high insertion force (>300g per pin) and mechanical strain relief. For marine or outdoor deployments, specify conformal coating (acrylic or silicone) over the entire connector assembly to block moisture ingress and salt aerosol. Regular visual inspection every 6–12 months is recommended; contact resistance measurements (target <100mΩ) can detect early degradation before field failures occur. The MSL1 rating simplifies pre-deployment storage, but outdoor field storage requires sealed enclosures to prevent moisture absorption.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


MEC1-120-02-FM-D-K

Samtec Inc.

CONN EDGE DUAL FMALE 40POS 0.039

In Stock: 48064

Submit RFQ