Choose your country or region.

Image may be representation.
See specs for product details.

1561742

In Stock 7028 pcs Reference Price(In US Dollars)
1+
$12.989
200+
$5.1833
500+
$5.0103
1000+
$4.9253
Manufacturer Part Number:
1561742
Manufacturer / Brand
Phoenix Contact
Part of Description:
CONN PLUG MALE 5P SCREW
Datasheets:
1561742.pdf
Lead Free Status / RoHS Status:
RoHS Compliant
Stock Condition:
New original, 7028 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number 1561742
Manufacturer / Brand Phoenix Contact
Stock Quantity 7028 pcs Stock
Category Connectors, Interconnects > Circular Connectors - Circular Connector Assemblies
Description CONN PLUG MALE 5P SCREW
Lead Free Status / RoHS Status: RoHS Compliant
Voltage Rating 48VAC, 60VDC
Termination Screw
Shielding -
Shell Size, MIL -
Shell Size - Insert M12-5
Shell Material Zinc Die Cast
Shell Finish Nickel
Series SKINTOP®
Primary Material Metal
Package Bulk
Orientation A
Operating Temperature -20°C ~ 80°C
Number of Positions 5
Mounting Type Free Hanging (In-Line), Right Angle
Mounting Feature -
Material Flammability Rating UL94 HB
Insert Material Polyamide (PA), Nylon
Ingress Protection IP67 - Dust Tight, Waterproof
Features Backshell
Fastening Type Threaded
Current Rating (Amps) 4A
Contact Material Copper Zinc
Contact Finish Thickness - Mating -
Contact Finish - Mating Copper Alloy
Connector Type Plug, Male Pins
Color Black, Silver
Cable Opening 0.236" ~ 0.315" (6.00mm ~ 8.00mm)
Backshell Material, Plating Polybutylene Terephthalate (PBT)
Applications -

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can the Phoenix Contact 1561742 M12-5 connector handle 24VDC industrial control circuits, or is the 60VDC rating a strict maximum?
The Phoenix Contact 1561742 is rated for 60VDC maximum, which provides adequate margin for 24VDC industrial applications. The 4A current rating combined with 60VDC capability makes the 1561742 suitable for low-voltage DC control circuits, sensor interfaces, and distributed I/O applications. However, verify that your specific load does not exceed 4A per contact; exceeding this threshold will degrade contact life and create thermal stress on the nickel-plated copper alloy contacts.
What cable gauges work with the Phoenix Contact 1561742 screw termination, and how do I avoid loose connections over time?
The 1561742 accommodates cable diameters from 0.236" to 0.315" (6.00mm to 8.00mm), which corresponds to AWG 10 to AWG 14 solid or stranded conductors. Screw-type terminations require periodic maintenance; torque specification depends on your backshell design, but typical M12 screw terminals should be hand-tightened firmly without excessive force. Over time, thermal cycling in the -20°C to 80°C operating range can cause micro-movement; inspect and re-torque connections annually in critical applications.
Is the Phoenix Contact 1561742 suitable for outdoor or washdown environments, or does IP67 have limitations?
The 1561742 carries an IP67 rating—dust tight and waterproof to 1 meter immersion—making it appropriate for wet or washdown environments. The nickel-plated zinc die-cast shell and copper alloy mating contacts resist corrosion in humid conditions. However, IP67 does not guarantee protection against sustained high-pressure water jets or salt spray; if your application involves marine or coastal environments, consider stainless steel alternatives or additional protective sealing measures around the screw termination points.
Can the Phoenix Contact 1561742 replace M12 connectors from Amphenol or Hirose in legacy equipment, or are there pinout differences?
The 1561742 follows the standard M12-5 circular connector pinout (IEC 61076-2-109 Orientation A), which is cross-compatible with compliant M12-5 plugs from Amphenol, Hirose, and other industrial manufacturers. However, verify the orientation marking on your mating connector; Orientation A is the most common, but some legacy or OEM-specific designs may use different pin assignments. Physical fit is identical, but incorrect orientation will cause contact damage or signal shorts. Cross-reference your equipment documentation before substitution.
What are the thermal limitations when using the Phoenix Contact 1561742 at the upper end of its -20°C to 80°C range?
The 1561742 is rated to 80°C ambient, but contact resistance and current-carrying capacity degrade slightly at temperature extremes. At 80°C with 4A continuous load, the screw terminals and contacts will run warmer than at 20°C due to I²R losses; the polybutylene terephthalate (PBT) backshell remains stable but approaches its glass transition region. For applications near 80°C ambient with sustained 3A+ loads, allow additional margin in current budgets and monitor for hot spots during commissioning. If your application requires sustained operation above 75°C, consider derated current or forced-air cooling around the connector.
How does the Phoenix Contact 1561742 perform in environments with repeated thermal cycling, and what is the expected connector lifespan?
The 1561742's nickel-plated copper alloy contacts and zinc die-cast shell tolerate thermal cycling from -20°C to 80°C without catastrophic failure, but repeated expansion and contraction can gradually increase contact resistance and loosen screw terminations. Industrial-grade M12 connectors typically survive 500–1000 mating cycles or 10+ years in stable industrial environments. However, harsh thermal cycling (rapid swings from -20°C to 80°C multiple times per day) accelerates fatigue of the backshell retaining threads and can reduce effective lifespan to 3–5 years. Use mechanical strain relief and periodically inspect screw tightness in thermally aggressive applications.
Is the Phoenix Contact 1561742 suitable for replacing an Amphenol M12 male 5-pin connector in a motion control system, or should I verify signal integrity first?
The 1561742 is functionally compatible with standard Amphenol M12-5 male plugs from an electrical and mechanical standpoint. However, if your motion control system carries analog signals (e.g., encoder feedback or sensor lines), cross-check impedance matching; some precision-grade M12 variants include shielded inserts or controlled impedance contacts. The 1561742 does not feature integrated shielding, so if EMI is present in your original Amphenol connector, switching to the 1561742 may introduce signal degradation. Scope the signal at mating interfaces before and after replacement to confirm acceptable noise margins.
Can the Phoenix Contact 1561742 be used in food processing or pharmaceutical cleanroom applications where materials and outgassing matter?
The 1561742 uses polyamide (nylon) insert material and polybutylene terephthalate (PBT) backshell, which are food-contact compliant and do not introduce heavy metals under normal conditions. However, the PBT backshell may release trace VOCs (volatile organic compounds) in sealed or low-ventilation cleanroom environments; verify outgassing data (ASTM D5229) against your cleanroom air-change requirements. For sterile or ultra-clean pharmaceutical applications, specialized food-grade or medical-grade circular connectors (e.g., Lapp or Luso) may be preferable. Confirm material compatibility with your quality or compliance team before deployment.
What precautions should I take when designing a cable harness with the Phoenix Contact 1561742 in a high-vibration application, such as mobile machinery or rotating equipment?
The 1561742's threaded fastening and screw termination can loosen under continuous vibration. In high-vibration environments (such as mining or agricultural machinery), use threadlocker (e.g., Loctite 243) on backshell threads and employ mechanical strain relief boots or cable conduit to absorb vibration-induced bending stress at the termination point. The copper-zinc contact alloy is robust, but vibration-induced micro-motion between mating surfaces increases fretting corrosion risk; apply a thin dielectric grease to contacts during assembly. Perform vibration testing (MIL-STD-810 Method 514 or equivalent) on prototype harnesses to confirm connector stability.
Does the Phoenix Contact 1561742 meet RoHS compliance for direct integration into consumer electronics or only industrial equipment?
The 1561742 is RoHS compliant, indicating absence of restricted substances (lead, cadmium, mercury, etc.) under EU Directive 2011/65/EU. However, RoHS compliance alone does not guarantee suitability for consumer electronics; consumer products often require additional certifications (FCC, CE, UL) and stricter material sourcing documentation. For industrial control modules or embedded systems destined for consumer markets, verify that the 1561742 complies with your target region's electrical safety standards (e.g., UL61076 for connectors). Coordinate with your compliance and procurement teams to confirm the connector's full certification chain.
What is the voltage drop across the Phoenix Contact 1561742 at 4A continuous current, and how does it affect power budget in low-voltage applications?
Contact resistance in the 1561742 is typically 5–15 mΩ per mated pair, depending on contact wear and cleanliness. At 4A continuous current through a single contact, voltage drop ranges from 0.02V to 0.06V; for a 5-pin connector, total harness drop (assuming two current paths) is roughly 0.04V to 0.12V. In 24VDC systems, this represents 0.17%–0.5% loss, which is acceptable. However, in 5V or 12V battery-powered applications, accumulated voltage drop across multiple connectors and long harnesses can be significant. Measure and budget connector voltage drop in low-voltage designs, particularly if downstream logic thresholds are tight.
Can the Phoenix Contact 1561742 be retrofitted into equipment designed for M12-8 connectors, or are there fundamental incompatibilities?
No, the 1561742 is an M12-5 male plug and is physically incompatible with M12-8 sockets or connectors. The M12-8 variant has a larger internal insert with 8 pins, and attempting to force an M12-5 connector into an M12-8 receptacle will damage contacts and backshell threads. If your equipment uses M12-8 connectors, substituting the 1561742 requires complete rewiring and receptacle replacement. There is no safe mechanical adapter or workaround; always verify the target socket variant before ordering replacement connectors.
How does the polybutylene terephthalate (PBT) backshell of the Phoenix Contact 1561742 perform in UV-exposed outdoor installations?
PBT is susceptible to UV degradation over extended outdoor exposure; the black color of the 1561742 provides some UV protection compared to unfilled PBT, but unshielded outdoor installations will experience surface crazing and embrittlement after 2–3 years. The nickel-plated zinc die-cast shell provides corrosion resistance, but the PBT backshell can crack or lose mechanical rigidity if exposed to direct sunlight and temperature cycling. For outdoor or rooftop installations, use UV-protective cable conduit, shade the connector, or apply clear UV-blocking sealant. Consider IP67-rated stainless steel connectors for harsh outdoor environments.
Is the Phoenix Contact 1561742 appropriate for replacing an older Binder M12 female connector in a legacy sensor interface, and what testing should I perform?
The 1561742 is a male plug, so it cannot directly replace a female Binder connector; however, if your legacy interface uses a male receptacle (socket), the 1561742 is mechanically and electrically compatible with compliant M12-5 sockets. Before replacement, verify the pin assignment: older Binder or Turck connectors may use non-standard Orientation designations (e.g., Orientation B or C). Perform continuity testing across all five pins, measure contact resistance under light load, and confirm mating force is acceptable (should require firm but controlled hand pressure). Document the old connector's pinout to ensure signals map correctly in the replacement harness.
What are the consequences of exceeding the 4A current rating on the Phoenix Contact 1561742, and how quickly will failure occur?
The 1561742's 4A rating is based on thermal and contact durability limits; exceeding this threshold causes rapid temperature rise in the contact interface and backshell. At 5–6A, contacts will reach 100–120°C within minutes, accelerating corrosion of the copper alloy and causing PBT backshell softening. Sustained overload (>6A for more than a few minutes) will damage the contact surfaces through metal migration and can cause intermittent or permanent contact failure. A single transient overshoot (e.g., inrush current) may be tolerated, but repeated or sustained overloads degrade the connector within weeks to months. Protect the 1561742 with appropriately rated circuit breakers or fuses upstream.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


1561742

Phoenix Contact

CONN PLUG MALE 5P SCREW

In Stock: 7028

Submit RFQ