Choose your country or region.

Panduit Corp
MFG PV14-10LFB-3K.jpg ImageView larger image
Image may be representation.
See specs for product details.

PV14-10LFB-3K

In Stock 68712 pcs Reference Price(In US Dollars)
1+
$0.4069
10+
$0.3984
25+
$0.3895
50+
$0.3804
100+
$0.3713
500+
$0.3623
1000+
$0.3351
Manufacturer Part Number:
PV14-10LFB-3K
Manufacturer / Brand
Panduit Corp
Part of Description:
CONN SPADE TERM 14-16AWG #10 BLU
Datasheets:
PV14-10LFB-3K(1).pdfPV14-10LFB-3K(2).pdfPV14-10LFB-3K(3).pdf
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 68712 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number PV14-10LFB-3K
Manufacturer / Brand Panduit Corp
Stock Quantity 68712 pcs Stock
Category Connectors, Interconnects > Terminals - Spade Connectors
Description CONN SPADE TERM 14-16AWG #10 BLU
Lead Free Status / RoHS Status: ROHS3 Compliant
Wire Gauge 14-16 AWG
Width - Outer Edges 0.330' (8.38mm)
Tongue Inside Opening 0.190' (4.83mm)
Termination Crimp
Terminal Type Spring, Snap
Stud/Tab Size 10 Stud
Series Pan-Term®
Package Tape & Reel (TR)
Mounting Type Free Hanging (In-Line)
Material - Insulation Vinyl
Length - Termination -
Length - Ring Center to Termination -
Length - Overall 0.920' (23.37mm)
Insulation Diameter 0.170' (4.32mm)
Insulation Insulated
Features -
Contact Material Copper
Contact Finish Tin
Color Blue
Base Product Number PV14

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can the PV14-10LFB-3K be used interchangeably with other 10-stud spade terminals rated for 14-16 AWG wire?
The PV14-10LFB-3K is designed for #10 studs with a tongue opening of 0.190" and outer width of 0.330". While many competitors offer 10-stud terminals for 14-16 AWG, dimensional tolerances on the tongue opening and stud fit vary between manufacturers. Before substituting the PV14-10LFB-3K with alternative brands, verify that the replacement terminal's tongue opening and stud diameter match your equipment's specifications. Mismatched dimensions can result in loose connections, increased contact resistance, or intermittent failures in field applications.
What wire gauge range is acceptable for crimping into the PV14-10LFB-3K, and what happens if I use wire outside this range?
The PV14-10LFB-3K accepts 14-16 AWG wire. Using 12 AWG or larger wire may produce insufficient crimp pressure on the terminal's barrel, leading to poor electrical contact and potential wire pullout under vibration or thermal cycling. Conversely, 18 AWG or smaller wire will not fill the crimp barrel adequately, resulting in a mechanically weak connection prone to failure in high-vibration environments. Always match the crimp die and wire gauge precisely to the PV14-10LFB-3K's specifications.
How does the butted seam design of the PV14-10LFB-3K affect corrosion resistance in wet or salt-spray environments?
The PV14-10LFB-3K features a butted seam construction, where the terminal's barrel edges meet but are not fully fused. While the tin contact finish and vinyl insulation provide baseline corrosion protection, the seam can trap moisture and accelerate corrosion in marine or outdoor applications with prolonged salt-spray exposure. For such environments, consider sealing the terminal with dielectric grease or selecting terminals with fully welded seams. Long-term reliability of the PV14-10LFB-3K in coastal installations should be validated through environmental testing.
Is the PV14-10LFB-3K suitable for high-temperature applications, and what are the limitations?
The PV14-10LFB-3K uses vinyl insulation, which typically degrades above 80–105°C depending on the specific vinyl compound. Panduit does not publish maximum operating temperature for this terminal. If your application requires sustained operation above 100°C, the vinyl insulation may become brittle, lose dielectric strength, or melt. For engine compartment, furnace, or industrial oven applications, select terminals with phenolic or polyimide insulation rated to higher temperatures. The PV14-10LFB-3K is best suited for ambient environments below 80°C.
What is the relationship between insulation diameter (0.170") and the actual wire size I need to use with the PV14-10LFB-3K?
The insulation diameter specification of 0.170" for the PV14-10LFB-3K indicates the outer diameter of insulation expected on crimped wires. This dimension ensures the vinyl sleeve of the terminal seats properly over the wire insulation after crimping. If your wire has an outer insulation diameter significantly larger (e.g., 0.190" or greater due to cross-linked polyethylene or specialty coatings), the PV14-10LFB-3K's vinyl sleeve may not fit securely, compromising strain relief. Verify wire insulation diameter before committing to production quantities.
Can the PV14-10LFB-3K accommodate power applications above 20 amperes, and what degradation occurs at higher currents?
The PV14-10LFB-3K is not specified for current ratings in Panduit's standard documentation, but 14-16 AWG copper wire typically supports 15–20 amperes at 20°C rise under steady-state conditions. The tin-plated copper contact of the PV14-10LFB-3K has low contact resistance when properly crimped, but sustained currents above 25 amperes will generate measurable heat at the crimp joint, accelerating insulation degradation and increasing the risk of thermal runaway. For applications requiring continuous currents above 20 amperes, upsize to 10-12 AWG wire or transition to a heavier-gauge terminal.
How do I verify that a crimp tool is correctly calibrated for the PV14-10LFB-3K?
The PV14-10LFB-3K requires a crimp die specifically matched to its barrel dimensions and wire gauge (14-16 AWG, #10 stud). Before production, perform a pull test on sample crimps: strip and extract the wire from the crimped terminal using a tensile tester or manual pull gauge rated to at least 50 lbf. A properly crimped PV14-10LFB-3K should retain the wire without slipping or breaking at 40–50 lbf. If the wire slides out or the terminal deforms, the crimp pressure is insufficient; if the wire breaks before slipping, the crimp may be too tight. Verify die clearance, pressure settings, and wire positioning with your tool manufacturer.
What is the spring tension specification for the PV14-10LFB-3K, and how does it affect connection reliability?
Panduit does not publish a spring tension or contact force specification for the PV14-10LFB-3K's snap-spring contact. The terminal design relies on the inherent stiffness of the copper alloy and the geometry of the spring tabs to maintain contact pressure against the #10 stud. Over repeated mating and unmating cycles (or in high-vibration environments), the spring tabs may relax, reducing contact pressure and increasing electrical resistance. If your application involves frequent disconnect/reconnect cycles or continuous vibration, test samples of the PV14-10LFB-3K in a representative environment to confirm contact stability after 100+ cycles.
Is the PV14-10LFB-3K compatible with plated studs, or should I use bare copper studs only?
The PV14-10LFB-3K will mate with both nickel-plated and bare copper #10 studs. However, contact resistance varies depending on plating thickness and surface finish. Nickel-plated studs introduce an additional contact interface that may have higher resistance than bare copper, particularly if the nickel layer is thin or has surface oxidation. For critical low-resistance applications (e.g., power distribution or precision instrumentation), confirm contact resistance through measurement (typically <2 mΩ per contact pair). If resistance is marginal, clean the stud contact surface before mating or request a higher-purity nickel plating specification.
How does the PV14-10LFB-3K perform in applications with frequent thermal cycling between –20°C and +60°C?
The vinyl insulation of the PV14-10LFB-3K will contract during cold cycles and expand during warm cycles. Over repeated thermal excursions, this differential expansion can cause micro-motion at the crimp interface, leading to fretting corrosion and increased contact resistance. Additionally, the spring tabs may lose some elasticity at low temperatures, reducing contact force. For automotive or outdoor applications with daily thermal cycling, validate the PV14-10LFB-3K's performance through accelerated thermal-shock testing (e.g., 50+ cycles from –20°C to +60°C) before full deployment. Consider conformal coating or potting to mitigate moisture ingress.
Can I use the PV14-10LFB-3K in DC applications with voltages above 48 VDC, and are there arcing or breakdown risks?
The PV14-10LFB-3K's vinyl insulation is rated for standard industrial voltages (typically up to 300 VAC for general-purpose terminals). The 0.170" insulation diameter and standard vinyl material provide adequate dielectric strength for most DC applications up to 60 VDC. However, at higher voltages (100+ VDC) or in the presence of moisture or contamination, the risk of tracking or arcing across the insulation surface increases. For 48 VDC or higher, ensure the PV14-10LFB-3K is mounted in a dry environment and that creepage distances between the stud and nearby conductors meet IEC or UL standards for your target voltage. Perform electrical safety testing if operating above 100 VDC.
What is the pull-out force specification for the PV14-10LFB-3K once crimped, and how does it relate to wire gauge?
Panduit does not publish a minimum pull-out force for the PV14-10LFB-3K. Industry practice for 14-16 AWG spade terminals is typically 40–60 lbf (180–270 N). The actual pull-out force depends on crimp quality, wire material (copper vs. copper-clad steel), insulation thickness, and the depth of the crimp barrel. If your application involves mechanical stress (e.g., vibration, recurring tension, or repeated mating), perform destructive pull tests on at least 10 sample crimps to establish a baseline and confidence interval. A weak baseline may indicate crimp-tool misalignment or incompatible wire type.
Is the PV14-10LFB-3K RoHS3 compliant, and what does that mean for lead-free sourcing and future regulatory changes?
Yes, the PV14-10LFB-3K is RoHS3 compliant, meaning it meets the current EU Restriction of Hazardous Substances directive and does not contain prohibited materials such as lead, cadmium, or hexavalent chromium. The tin contact finish is lead-free. However, RoHS3 compliance does not guarantee compatibility with future regulatory tightening (e.g., phthalate restrictions on vinyl insulation or mercury limits). For long-term product support or certifications required in regulated markets (automotive, medical), confirm with Panduit that the PV14-10LFB-3K will remain compliant for the duration of your product's lifecycle.
Can the PV14-10LFB-3K be used as a direct replacement for older spade terminals with different stud sizes or wire gauges?
The PV14-10LFB-3K is engineered specifically for #10 studs and 14-16 AWG wire. If your legacy equipment uses #6 or #8 studs, or if wire gauges differ (12 AWG or 18 AWG), the PV14-10LFB-3K cannot be substituted without modifying the stud or upgrading the wire gauge. Attempting a forced fit will result in poor contact, mechanical damage, or safety hazards. Before retrofitting a system with the PV14-10LFB-3K, audit all studs and wire gauges in the assembly and confirm that all combinations meet the terminal's specifications. Mixed stud sizes or wire gauges within a single harness may require multiple terminal types.
How should I store the PV14-10LFB-3K to prevent oxidation or corrosion before installation?
The PV14-10LFB-3K should be stored in a dry environment (relative humidity <60%) in its original cut-tape packaging or sealed moisture-barrier bags. The tin-plated copper contact is resistant to oxidation but can still tarnish if exposed to corrosive atmospheres (e.g., sulfur compounds or acid fumes). Avoid storage near salt spray, chemical fumes, or high-humidity areas. If the terminal is stored for extended periods (>6 months) or in marginal humidity, inspect the contact surface visually or measure contact resistance before use. Tarnished contacts may show elevated resistance; light cleaning with an eraser or contact cleaner can restore performance, but heavily oxidized terminals should be replaced.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


PV14-10LFB-3K

PV14-10LFB-3K

Panduit Corp

CONN SPADE TERM 14-16AWG #10 BLU

In Stock: 68712

SUBMIT RFQ