Choose your country or region.

Image may be representation.
See specs for product details.

FC2ZN-24-10U

In Stock 83 pcs Reference Price(In US Dollars)
1+
$520.0259
200+
$488.4076
500+
$472.0869
1000+
$464.0227
Manufacturer Part Number:
FC2ZN-24-10U
Manufacturer / Brand
Panduit Corp
Part of Description:
OM4 FIBER; STANDARD LOSS; 24 FIB
Datasheets:
Lead Free Status / RoHS Status:
RoHS Compliant
Stock Condition:
New original, 83 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number FC2ZN-24-10U
Manufacturer / Brand Panduit Corp
Stock Quantity 83 pcs Stock
Category Connectors, Interconnects > Fiber Optic Connectors - Fiber Optic Connector Adapters
Description OM4 FIBER; STANDARD LOSS; 24 FIB
Lead Free Status / RoHS Status: RoHS Compliant
Type Adapter
Simplex/Duplex 24-Plex
Mounting Type Free Hanging (In-Line)
Mode Multimode OM4
Housing Material -
Ferrule Material Zirconia, Ceramic
Features -
Convert To (Adapter End) MPO Receptacle
Convert From (Adapter End) LC Receptacle
Color Aqua

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can the Panduit FC2ZN-24-10U be used to transition an OM4 LC patch panel to an MPO trunk in a 40G or 100G multimode link?
Yes, the Panduit FC2ZN-24-10U is an LC receptacle to MPO receptacle in-line adapter for OM4 multimode fiber, so it can be used when a design needs to bridge LC-based equipment or patching to an MPO-based backbone. In practice, the FC2ZN-24-10U should be used only when the channel budget still meets the transceiver and cabling requirements after adding adapter loss, polarity handling, and any additional patch cords. For 40G and 100G links, confirm that the MPO fiber count, polarity scheme, and breakout method match the optics and cabling architecture before installing the FC2ZN-24-10U.
What should I check before using the Panduit FC2ZN-24-10U in a permanent rack-to-rack installation?
The Panduit FC2ZN-24-10U is a free-hanging in-line adapter, so the first check is whether the installation will leave the adapter supported by the cabling or whether it needs a fixed panel or enclosure for strain relief. For long-term rack use, verify that cable management prevents side load on the LC and MPO interfaces, and confirm that the in-line location does not make inspection, cleaning, or service access difficult. The FC2ZN-24-10U is best used where the connection point can remain mechanically stable and protected from repeated movement.
Is the Panduit FC2ZN-24-10U suitable for singlemode fiber systems or only OM4 multimode networks?
The Panduit FC2ZN-24-10U is specified for OM4 multimode fiber, so it is intended for multimode systems rather than singlemode links. In singlemode designs, connector geometry, optical loss expectations, and system compatibility differ enough that a multimode adapter such as the FC2ZN-24-10U is not a proper substitute. For migration work, confirm the transceiver type, fiber type, and installed plant before using the FC2ZN-24-10U in the channel.
How does the Panduit FC2ZN-24-10U affect insertion loss in a high-density optical channel?
Any adapter adds some insertion loss, connector pair interfaces, and a small amount of optical variability, so the Panduit FC2ZN-24-10U should be included in the link budget rather than treated as neutral hardware. In dense OM4 channels, the practical question is whether the extra connection point still leaves margin for transmitter aging, contamination, and field rework. If the channel is already near its loss limit, the FC2ZN-24-10U may still function, but the design should be verified with the full connector and patch-cord path included.
Can the Panduit FC2ZN-24-10U be used to adapt between LC patch cords and MPO cassette modules without changing polarity?
The Panduit FC2ZN-24-10U provides an LC receptacle to MPO receptacle transition, but it does not solve polarity by itself. MPO-based channels still need a defined polarity method across trunks, cassettes, patch cords, and transceiver orientation. When using the FC2ZN-24-10U, confirm that the selected MPO keying, cassette mapping, and end-to-end polarity scheme are consistent with the equipment being connected.
What are the practical reasons to choose the Panduit FC2ZN-24-10U instead of replacing the whole fiber assembly?
The Panduit FC2ZN-24-10U is useful when an existing LC plant must interface with an MPO backbone and the installed cabling still has usable life. It can reduce retermination work, shorten downtime, and preserve existing LC-side assets while allowing a higher-density MPO side to remain in service. The trade-off is an extra mated interface, so the decision usually depends on whether the added connection loss and maintenance access fit the channel design.
Is the Panduit FC2ZN-24-10U a good fit for data center migrations from LC-based 10G links to MPO-based parallel optics?
The Panduit FC2ZN-24-10U can be part of a migration path when LC ports and MPO trunks must coexist during phased upgrades. It is most practical where old and new infrastructure overlap, such as staged moves from duplex LC links to parallel-fiber MPO connectivity. The design should still account for the final optical standard, polarity mapping, and whether a direct cable replacement would offer better loss and serviceability than an adapter bridge.
What replacement or alternate part options should I consider if I need the same LC-to-MPO function as the Panduit FC2ZN-24-10U?
If you need the same LC-to-MPO conversion as the Panduit FC2ZN-24-10U, the main alternatives are other LC-to-MPO adapters from vendors that match the same OM4 multimode, connector interface, and density requirements. When comparing replacements, check the MPO interface style, supported fiber mode, panel or in-line mounting style, and measured insertion loss rather than relying only on the connector family name. A substitute for the FC2ZN-24-10U should also be evaluated for polarity compatibility and mechanical fit in the intended housing or management system.
Can the Panduit FC2ZN-24-10U be used in industrial environments with vibration or repeated cable movement?
The Panduit FC2ZN-24-10U is a fiber optic adapter rather than a ruggedized industrial connector system, so vibration tolerance depends heavily on how the cables are supported and restrained. In equipment cabinets with movement or vibration, use proper strain relief, avoid suspended load on the adapter body, and inspect the connector interfaces periodically. If the application has frequent shock, flexing, or field service cycles, the FC2ZN-24-10U is better treated as a managed interconnect point than as a mechanically isolated connection.
Does the Panduit FC2ZN-24-10U require any special cleaning or inspection practice before installation?
Yes, the Panduit FC2ZN-24-10U should be handled like any precision optical interface: inspect and clean both the LC and MPO sides before mating. Dust or residue on either side can raise loss and create unstable link performance, especially in OM4 channels where margin may already be limited by the channel design. A clean mating sequence and routine inspection are the practical steps that keep the FC2ZN-24-10U performing as intended.
Can I use the Panduit FC2ZN-24-10U as a direct substitute for a panel-mounted adapter in a fiber enclosure?
The Panduit FC2ZN-24-10U is a free-hanging in-line adapter, so it is not a direct mechanical substitute for a panel-mounted part unless the enclosure is designed to support inline interconnects. In a panel environment, the key questions are strain relief, retention, port density, and service access, all of which are handled differently from an in-line adapter. If the enclosure expects fixed-port hardware, choose a panel-compatible connector solution instead of forcing the FC2ZN-24-10U into that role.
What operating conditions should I verify before using the Panduit FC2ZN-24-10U in a long-life installation?
The Panduit FC2ZN-24-10U is rated for 0°C to 70°C, so the installed environment should stay within that range at the connector location, not just at the room level. For long-life use, also verify humidity control, contamination management, and physical protection from bending or tugging. In practice, stable temperature, clean mating surfaces, and restrained cabling matter as much as the published temperature range when the FC2ZN-24-10U is used in a serviceable network path.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


FC2ZN-24-10U

Panduit Corp

OM4 FIBER; STANDARD LOSS; 24 FIB

In Stock: 83

SUBMIT RFQ