Choose your country or region.

Image may be representation.
See specs for product details.

AYLD39902DN-G-240V

Manufacturer Part Number:
AYLD39902DN-G-240V
Manufacturer / Brand
IDEC
Part of Description:
PB EMERGENCY STOP 30MM
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 30112 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number AYLD39902DN-G-240V
Manufacturer / Brand IDEC
Stock Quantity 30112 pcs Stock
Category Switches > Emergency Stop (E-Stop) Switches
Description PB EMERGENCY STOP 30MM
Lead Free Status / RoHS Status: ROHS3 Compliant
Series -
Package Bulk
Condition New Original Stock
Warranty 100% Perfect Functions
Lead Time 2-3days after payment.
Payment Credit Card / PayPal / Telegraphic Transfer (T/T) / Western Union
Shipping by DHL / Fedex / UPS / TNT
Port HongKong
RFQ Email Info@IC-Components.com

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can AYLD39902DN-G-240V be used in a 240 V industrial control circuit without adding extra interface components?
AYLD39902DN-G-240V is specified for a 240 V application, so it can be applied in control panels that match that operating class. In practice, the surrounding circuit still needs to confirm contact ratings, load type, and any surge or inrush current present at the field wiring. For a safety-related emergency-stop chain, designers typically verify that the complete architecture, not only AYLD39902DN-G-240V, satisfies the required stop category, wiring method, and fault detection approach.
What should I check when replacing an existing emergency stop switch with AYLD39902DN-G-240V?
When replacing a panel device with AYLD39902DN-G-240V, the main checks are panel cutout size, mounting depth, actuator diameter, contact block arrangement, and terminal style. Electrical compatibility also matters if the original switch used a different contact logic or different voltage class. If the existing circuit expects a maintained emergency-stop function and the original part has a different mechanical release or reset behavior, the replacement must be validated at the machine level.
Is AYLD39902DN-G-240V suitable for direct integration into PLC safety inputs?
AYLD39902DN-G-240V can be used as part of a safety input chain, but the PLC interface needs to match the contact behavior and diagnostic concept. Engineers usually confirm whether the switch provides the required normally closed contact path, whether dual-channel monitoring is used, and whether the safety module detects shorts or welded contacts. For a direct PLC safety input, AYLD39902DN-G-240V should be evaluated together with the safety relay or safety controller rather than as a standalone field device.
What wiring and contact logic considerations matter for AYLD39902DN-G-240V in an emergency-stop circuit?
With AYLD39902DN-G-240V, the wiring question is usually whether the machine uses single-channel or dual-channel safety wiring, and how the contacts are arranged for monitored disconnection. Many emergency-stop designs use positively guided contacts and a safety relay to detect line faults. If the control cabinet has long cable runs, designers also consider voltage drop, induced noise, and whether the chosen termination method keeps the loop reliable over time.
Can AYLD39902DN-G-240V replace an IDEC emergency-stop part with a different suffix or model family?
AYLD39902DN-G-240V may be a practical substitute only when the replacement matches the mounting geometry, actuator style, contact configuration, and electrical rating of the original IDEC part. Model suffixes often reflect differences such as color, legend, operator form, or terminal options, so those details need confirmation before substitution. If the original design depends on a specific bezel size or illuminated accessory set, the migration should be checked against the exact panel hardware.
What are the main risks when using AYLD39902DN-G-240V in a high-duty industrial environment?
In high-duty use, AYLD39902DN-G-240V should be evaluated for mechanical cycle life, vibration exposure, contamination, and the likelihood of repeated activation during maintenance. Emergency-stop operators often survive the electrical load but wear mechanically through repeated actuation, panel shock, or ingress around the front seal. In harsh equipment, designers commonly pair the switch with periodic functional testing and inspection of the actuator, contacts, and mounting hardware.
Is AYLD39902DN-G-240V appropriate for outdoor or washdown installations?
AYLD39902DN-G-240V can be considered for exposed environments only if the full assembly, including the enclosure and sealing arrangement, supports the site conditions. For outdoor or washdown service, the limiting factor is often not the switch body alone but the panel cutout, gasket compression, and exposure to moisture, chemicals, or UV. If the application sees direct spray or frequent cleaning, the surrounding enclosure rating and maintenance interval should be verified.
How do I verify that AYLD39902DN-G-240V is a good fit when migrating from a different brand of emergency-stop button?
For a cross-brand migration to AYLD39902DN-G-240V, engineers usually compare bezel diameter, panel hole pattern, contact block stack-up, release mechanism, and the safety relay interface. Even when two buttons look similar, the actuator travel, latching feel, and terminal orientation can differ enough to affect installation time and serviceability. A field retrofit is smoother when the replacement keeps the same panel footprint and contact behavior as the original device.
What design checks are needed if AYLD39902DN-G-240V will be used in a machine that runs continuously?
Continuous-duty systems using AYLD39902DN-G-240V should confirm that the switch is not exposed to unnecessary mechanical cycling and that the surrounding safety circuit does not generate nuisance activations. Designers often validate temperature rise inside the enclosure, wire termination stability, and the ease of periodic inspection during planned downtime. For 24/7 equipment, the service strategy around AYLD39902DN-G-240V can matter as much as the initial wiring.
Are there substitute parts for AYLD39902DN-G-240V, and what should be checked before using one?
IDEC lists AYLD3QM402DNUG as a substitute for AYLD39902DN-G-240V, but the final selection still needs a fit check against the exact application. The engineer should confirm actuator dimensions, terminal compatibility, contact arrangement, and any differences in the operating feel or mounting depth. If the machine relies on a specific emergency-stop operator shape or panel aesthetic, those mechanical details should be reviewed before changing from AYLD39902DN-G-240V to the substitute.
What should I consider about spare-parts stocking for AYLD39902DN-G-240V in production equipment?
For spare-parts planning, AYLD39902DN-G-240V is usually stocked by matching the exact part number to avoid differences in bezel, contact block, or release mechanism during maintenance. In production lines, the practical question is whether the same replacement can be installed without reworking the panel or changing the safety logic. Keeping AYLD39902DN-G-240V as a documented service part reduces ambiguity when technicians replace a damaged emergency-stop station.
Does AYLD39902DN-G-240V require any special consideration for long cable runs between the switch and the safety relay?
Long runs from AYLD39902DN-G-240V to the safety relay are mainly a wiring integrity issue. Designers normally check conductor size, loop resistance, cable routing, and the effect of electromagnetic noise from nearby drives or contactors. If the cable run is extended, the safety loop should still open cleanly and be able to detect a fault condition without ambiguity.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


AYLD39902DN-G-240V

IDEC

PB EMERGENCY STOP 30MM

In Stock: 30112

SUBMIT RFQ