Choose your country or region.

Littelfuse Inc.
P1300SCMC ImageView larger image
Image may be representation.
See specs for product details.

P1300SCMC

Manufacturer Part Number:
P1300SCMC
Manufacturer / Brand
Littelfuse Inc.
Part of Description:
THYRISTOR 120V 400A DO214AA
Datasheets:
P1300SCMC.pdf
Lead Free Status / RoHS Status:
RoHS non-compliant
Stock Condition:
New original, 40557 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number P1300SCMC
Manufacturer / Brand Littelfuse Inc.
Stock Quantity 40557 pcs Stock
Category Circuit Protection > Transient Voltage Suppressors (TVS) - Thyristors
Description THYRISTOR 120V 400A DO214AA
Lead Free Status / RoHS Status: RoHS non-compliant
Voltage - On State 5 V
Voltage - Off State 120V
Voltage - Breakover 160V
Supplier Device Package DO-214AA
Series SIDACtor®
Package / Case DO-214AA, SMB
Package Bulk
Number of Elements 1
Mounting Type Surface Mount
Current - Peak Pulse (8/20µs) 400 A
Current - Peak Pulse (10/1000µs) 100 A
Current - Hold (Ih) 150 mA
Capacitance 60pF

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Is P1300SCMC suitable for a 120 V line, or will it trigger too early in a real design?
P1300SCMC is intended for circuits whose normal working voltage stays below its 120 V off-state rating, with surge events allowed to push it into conduction at a higher breakover level. In a real design, the key check is the maximum steady-state voltage including tolerance, ripple, and fault conditions, not just the nominal line value. If the applied waveform can approach or exceed the off-state limit for extended periods, P1300SCMC is not a good fit.
Do I need a fuse, PTC, or other current-limiting part with P1300SCMC?
Yes, P1300SCMC is a crowbar-style protection device, so it is normally paired with a series impedance or upstream overcurrent protection. Once it fires, it can conduct heavily and stay on until current falls below its hold current, so a fuse, PTC, or source-limited supply is used to clear the fault. Without coordination, the protected line or the SIDACtor itself can remain stressed after a surge.
Can P1300SCMC be used on high-speed data or low-capacitance signal lines?
P1300SCMC has about 60 pF capacitance, which is acceptable for many telecom and industrial interfaces but can be intrusive on very fast or high-impedance signal paths. For multi-Mbps digital links, RF paths, or precision analog nodes, that capacitance can alter edge rates, insertion loss, or impedance matching. In those cases, a lower-capacitance protection device is usually a better starting point than P1300SCMC.
What happens after P1300SCMC fires during a surge, and how does it reset?
P1300SCMC can latch into conduction after a surge if the line current exceeds its hold current of 150 mA. It resets only when the current through the device drops below that level, which may happen naturally in a low-current DC system after the fault clears or at the zero crossings of an AC waveform. If the source can keep supplying current, external current limiting is needed to let the circuit recover.
Is P1300SCMC a direct replacement for P1300SCMCLRP or SMTPA120?
P1300SCMC can be electrically close to P1300SCMCLRP if the voltage rating, surge current, capacitance, and SMB footprint all match the target board constraints, but the suffix should still be checked for packaging and compliance differences. For SMTPA120, the device may serve a similar protection role, yet it should not be assumed to be pin-compatible without verifying the package outline, trigger behavior, hold current, and surge ratings. For any migration, P1300SCMC should be compared against the exact line-voltage profile and the clearing method used in the original design.
Can P1300SCMC replace a MOV or a standard TVS diode in my protection network?
P1300SCMC behaves differently from a MOV or a unidirectional TVS diode. Compared with a MOV, it typically offers lower capacitance and a more defined crowbar action, which is useful on communication-style lines; compared with a TVS diode, it generally does not clamp in the same way and instead switches hard into conduction. If your circuit needs a precise clamp voltage for sensitive semiconductor rails, a TVS diode is often the more direct choice; if the design benefits from a latching surge shunt on a line that can be current-limited, P1300SCMC is a reasonable option.
Is P1300SCMC appropriate for 120 VAC mains protection?
P1300SCMC is not a straightforward choice for 120 VAC mains because the peak of a 120 VAC waveform is around 170 V, which exceeds its 120 V off-state rating. That makes it better suited to lower-voltage line interfaces and controlled-voltage circuits rather than direct connection across mains. For mains input stages, designers usually use protection parts specifically rated for the mains waveform and its surge environment.
How should I place P1300SCMC on the PCB to get reliable surge performance?
P1300SCMC should be placed as close as practical to the protected connector or line entry point so the surge current path stays short and low inductance. Wide copper, short traces, and a clean return path help the device divert surge energy before it couples into sensitive circuitry. In board-level design, the trace inductance around P1300SCMC can matter as much as the device rating itself during fast transients.
What should I check for industrial or long-term use with P1300SCMC?
P1300SCMC is in an SMB/DO-214AA surface-mount package, so long-term performance depends on solder joint quality, thermal cycling, and how often the line sees surge events. Moisture Sensitivity Level 1 indicates unlimited floor life under normal storage, but surge robustness still depends on PCB layout, copper area, and fault-clearing coordination. For industrial equipment, it is also worth checking regulatory and sourcing constraints because P1300SCMC is listed as RoHS non-compliant, which can affect qualification and procurement choices.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


P1300SCMC

P1300SCMC

Littelfuse Inc.

THYRISTOR 120V 400A DO214AA

In Stock: 40557

Submit RFQ