Choose your country or region.

EDAC Inc.
MFG 516-056-500-615.jpg ImageView larger image
Image may be representation.
See specs for product details.

516-056-500-615

In Stock 725 pcs Reference Price(In US Dollars)
25+
$53.0457
Manufacturer Part Number:
516-056-500-615
Manufacturer / Brand
EDAC Inc.
Part of Description:
516 SERIES RACK & PANEL CONNECTO
Datasheets:
516-056-500-615(1).pdf516-056-500-615(2).pdf
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 725 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number 516-056-500-615
Manufacturer / Brand EDAC Inc.
Stock Quantity 725 pcs Stock
Category Connectors, Interconnects > Backplane Connectors - Backplane Connector Housings
Description 516 SERIES RACK & PANEL CONNECTO
Lead Free Status / RoHS Status: ROHS3 Compliant
Series 516
Pitch 0.150" (3.81mm)
Package Box
Number of Rows 9
Number of Positions 56
Note Contacts Not Included
Mounting Type Free Hanging (In-Line)
Features Backshell, Jackscrew
Connector Usage Receptacle
Connector Type Housing for Non-Gendered Contacts
Connector Style Rack and Panel
Color Green
Base Product Number 516-056

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

For Mercury United Electronics 516-056-500-615, what should I check before using it in a new rack-and-panel design?
With Mercury United Electronics 516-056-500-615, confirm that your mechanical envelope, mating alignment, and contact system all match the target interface. This part is a 56-position housing for non-gendered contacts in a rack-and-panel style, so the real design check is whether your chassis spacing, board-to-cable transition, and mating tolerance can support the backshell and jackscrew hardware without interference. Because contacts are not included, the contact family and termination method need to be selected separately and validated as a set.
Can Mercury United Electronics 516-056-500-615 be used as a direct replacement if I already have another 56-position rack-and-panel connector?
Mercury United Electronics 516-056-500-615 is only a practical direct replacement when the existing part matches the same 56-position layout, 0.150 inch pitch, 9-row arrangement, and non-gendered contact architecture. Even if the cavity count looks similar, differences in shell geometry, jackscrew placement, backshell clearance, and contact vendor geometry can prevent interchangeability. For a migration, verify mating dimensions, panel cutout, contact part number, and termination style before treating it as a drop-in substitute.
What contact parts should I pair with Mercury United Electronics 516-056-500-615, and what can go wrong if I mix families?
Mercury United Electronics 516-056-500-615 is a housing only, so the contact family has to be chosen for the wire gauge, current, termination method, and plating you need. Mixing contacts from a different family can create insertion-force issues, unreliable retention, or poor electrical engagement even when the connector appears to fit. The safest approach is to use the contact series intended for the 516 family and confirm the termination tooling and inspection process before release.
Is Mercury United Electronics 516-056-500-615 suitable for cable assemblies that need frequent mating and unmating?
Mercury United Electronics 516-056-500-615 can be used in repeatedly serviced assemblies if the contact system and cable strain relief are designed for the expected cycle count. The housing’s jackscrew features help with controlled engagement, but wear is usually driven by the contacts, wire termination, and handling of the backshell area. For maintenance-heavy systems, validate mating force, retention, and post-cycle contact resistance on the full assembly rather than on the housing alone.
How does the backshell and jackscrew on Mercury United Electronics 516-056-500-615 affect integration into an enclosure?
The backshell and jackscrew on Mercury United Electronics 516-056-500-615 change the mechanical keep-out around the connector, so enclosure spacing and adjacent harness routing need to be checked early. In practice, these features improve alignment and retention, but they also introduce clearance requirements for tools and fastener access. If the connector sits near other hardware, confirm that the backshell does not block cable bend radius or interfere with neighboring modules.
Can Mercury United Electronics 516-056-500-615 be used in industrial environments with vibration?
Mercury United Electronics 516-056-500-615 is a reasonable candidate for vibration-prone equipment when the mating hardware, cable support, and contact system are specified as a matched assembly. The jackscrew mechanism helps maintain engagement under movement, but the final robustness depends on panel stiffness, harness strain relief, and whether the contacts are rated for the environment. For industrial use, test the completed assembly for fretting, loosening, and contact resistance drift under the actual vibration profile.
What are the main risks when migrating from a gendered connector to Mercury United Electronics 516-056-500-615?
Migrating to Mercury United Electronics 516-056-500-615 changes the interface architecture because it uses non-gendered contacts rather than a conventional pin-and-socket pair. That can alter mating sequences, tooling, and service procedures, especially if the legacy design relied on one-sided contact wear or a specific polarization scheme. Before switching, verify polarity control, keying strategy, and whether the existing cable-side and backplane-side parts still make sense as a matched pair.
Is Mercury United Electronics 516-056-500-615 appropriate for a high-density signal backplane?
Mercury United Electronics 516-056-500-615 can fit high-density backplane architectures where the 56-position, 9-row layout and 3.81 mm pitch align with the required channel count. Suitability depends less on the cavity count and more on signal integrity, crosstalk management, and the contact system selected for the actual data rates. For faster links, validate insertion loss, return loss, and pair-to-pair spacing in the assembled system instead of assuming the housing alone will preserve signal quality.
How do I confirm Mercury United Electronics 516-056-500-615 will fit my existing panel or chassis opening?
Mercury United Electronics 516-056-500-615 should be checked against the full mechanical drawing, including connector body depth, backshell overhang, jackscrew location, and the mounting envelope for the free-hanging assembly. A housing can match the nominal position count yet still fail in a retrofit because the service loop or fastener access is different. The practical check is to compare the complete assembly stack-up, not just the mating face dimensions.
Is Mercury United Electronics 516-056-500-615 a good choice for long-term availability and production use?
Mercury United Electronics 516-056-500-615 can work well in production if your supply chain can source both the housing and the corresponding contacts consistently. Because it is a housing-only item, long-term continuity depends on the connector family rather than the shell by itself. For a lifecycle-sensitive design, confirm alternate sources, approved contact equivalents, and any tooling dependencies before locking the BOM.
What should I consider if I need to replace Mercury United Electronics 516-056-500-615 with an alternative brand?
Replacing Mercury United Electronics 516-056-500-615 with another brand usually requires checking more than position count and pitch. The critical comparisons are contact geometry, retention method, polarizing features, shell depth, jackscrew thread details, and the backshell interface. Even when another manufacturer offers a similar rack-and-panel housing, small dimensional differences can affect mating force, repairability, and field interchangeability.
Can Mercury United Electronics 516-056-500-615 be used in prototypes even if I have not finalized the contact selection?
Mercury United Electronics 516-056-500-615 can be used in prototype builds, but only if the contact family is selected early enough to validate fit, termination, and assembly process. The housing alone does not establish electrical performance, and prototype issues often come from contact selection, tooling mismatch, or insufficient cable strain relief. It is usually better to treat the housing and contacts as one validated assembly so prototype results carry into production without rework.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


516-056-500-615

516-056-500-615

EDAC Inc.

516 SERIES RACK & PANEL CONNECTO

In Stock: 725

SUBMIT RFQ