Choose your country or region.

Image may be representation.
See specs for product details.

2-5700-IG1-P10-A3-DD-7A

In Stock 1392 pcs Reference Price(In US Dollars)
10+
$21.7913
Manufacturer Part Number:
2-5700-IG1-P10-A3-DD-7A
Manufacturer / Brand
E-T-A
Part of Description:
CIR BRKR THRM 7A 250VAC 50VDC
Datasheets:
2-5700-IG1-P10-A3-DD-7A.pdf
Lead Free Status / RoHS Status:
Lead free / RoHS Compliant
Stock Condition:
New original, 1392 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number 2-5700-IG1-P10-A3-DD-7A
Manufacturer / Brand E-T-A
Stock Quantity 1392 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIR BRKR THRM 7A 250VAC 50VDC
Lead Free Status / RoHS Status: Lead free / RoHS Compliant
Voltage Rating - DC 50V
Voltage Rating - AC 250V
Standard Package 10
Series 2-5700
Part Status Active
Number of Poles 1
Mounting Type Panel Mount
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Manufacturer Standard Lead Time 7 Weeks
Lead Free Status / RoHS Status Lead free / RoHS Compliant
Illumination Voltage (Nominal) -
Illumination -
Current Rating 7A
Breaker Type Thermal
Actuator Type Push-Push

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can I use 2-5700-IG1-P10-A3-DD-7A as resettable overcurrent protection for a 24 VDC control panel, or do I still need a fuse upstream?
2-5700-IG1-P10-A3-DD-7A can be used as a resettable thermal protector in a 24 VDC panel, but it is typically best treated as supplementary protection rather than the only protective device. Because it is rated for 50 VDC and is UL1077 listed, many designs pair 2-5700-IG1-P10-A3-DD-7A with an upstream fuse, breaker, or supply-limited source so the system still has a defined short-circuit clearing path. That approach is especially useful when the load wiring is long, the supply can deliver high fault current, or compliance requires a separate branch-circuit protective device.
Will 2-5700-IG1-P10-A3-DD-7A trip reliably with motor starts, transformer inrush, or large capacitive loads?
2-5700-IG1-P10-A3-DD-7A is a thermal breaker, so it reacts to heating rather than instant magnetic trip behavior. That makes it suitable for moderate overload protection, but high inrush loads such as motors, transformers, SMPS input capacitors, and solenoids can cause nuisance trips if the start surge is close to the thermal threshold. For 2-5700-IG1-P10-A3-DD-7A, designers usually verify the startup current profile, duty cycle, ambient temperature, and enclosure heat rise before finalizing the selection. If the load has repeated inrush events, a breaker with different trip characteristics or a staged protection scheme may fit better.
Is 2-5700-IG1-P10-A3-DD-7A suitable when I need to protect only one conductor in a single-line AC or DC design?
Yes, 2-5700-IG1-P10-A3-DD-7A is a single-pole protector, so it is commonly used to interrupt one conductor in a control circuit or equipment branch. In AC systems, many designers place the breaker in the line conductor only, while in DC systems the conductor arrangement should follow the system grounding strategy and safety requirements. If your application requires simultaneous disconnection of both conductors, or if the equipment standard calls for full isolation, then a single-pole device like 2-5700-IG1-P10-A3-DD-7A may not be sufficient by itself.
What should I check before replacing another breaker with 2-5700-IG1-P10-A3-DD-7A in an existing panel?
When replacing an existing device with 2-5700-IG1-P10-A3-DD-7A, the main checks are mechanical fit, mounting method, electrical rating, and trip behavior. Even if the current rating matches, the panel cutout, bezel style, actuator travel, and depth behind the panel can differ from the original part. You should also confirm that the thermal response is compatible with the load profile, because two 7 A devices can behave differently under overload and inrush conditions. For retrofit work, comparing the original part’s outline drawing and terminal style against 2-5700-IG1-P10-A3-DD-7A helps avoid installation changes.
Are the substitute parts 1110-F212-P1M1-7A, 2-5700-IG1-P10-DD-7A, and 1110-F112-P1M1-7A direct drop-in replacements for 2-5700-IG1-P10-A3-DD-7A?
They may be functionally similar, but a direct drop-in replacement for 2-5700-IG1-P10-A3-DD-7A should only be assumed after checking the mechanical and electrical details. The substitute models 1110-F212-P1M1-7A, 2-5700-IG1-P10-DD-7A, and 1110-F112-P1M1-7A can differ in actuator style, front-panel interface, terminal arrangement, or internal trip behavior even when the ampere rating is the same. In a migration project, verify panel cutout compatibility, push action feel, reset indication requirements, and any differences in approvals or temperature performance before changing to one of those substitutes.
Does the push-push actuator on 2-5700-IG1-P10-A3-DD-7A affect how I should design the user interface or service workflow?
Yes, the push-push mechanism on 2-5700-IG1-P10-A3-DD-7A changes both operator behavior and maintenance logic. A push-push breaker is typically used when the design wants a simple manual reset action without a separate toggle lever, which can be helpful on compact front panels or sealed enclosures. For service workflows, 2-5700-IG1-P10-A3-DD-7A can simplify reset after a trip, but engineers should confirm that the panel labeling clearly distinguishes normal reset from fault clearing, especially in equipment where an operator might repeatedly restore power without diagnosing the overload source.
Can 2-5700-IG1-P10-A3-DD-7A be used in industrial equipment that runs continuously in warm enclosures?
2-5700-IG1-P10-A3-DD-7A can be used in continuous-duty equipment, but thermal breakers are sensitive to ambient temperature and self-heating from nearby components. In a warm enclosure, the effective trip point can shift earlier, so a breaker that works at the bench may nuisance-trip once installed next to power supplies, drives, or resistive loads. For 2-5700-IG1-P10-A3-DD-7A, it is common to validate performance at the actual enclosure temperature, mounting orientation, and ventilation condition rather than relying only on room-temperature testing.
Is 2-5700-IG1-P10-A3-DD-7A a good choice if I need a breaker for both 230 VAC mains and low-voltage DC equipment in the same product family?
2-5700-IG1-P10-A3-DD-7A can fit mixed-voltage product families because it is rated for 250 VAC and 50 VDC, but the protection design still needs to be reviewed separately for each platform. AC mains systems have different arc interruption and fault-energy behavior than low-voltage DC systems, so the same breaker model should not be assumed to provide identical performance in both cases. For 2-5700-IG1-P10-A3-DD-7A, designers should confirm the load type, wiring category, and downstream fault current for each version of the product before standardizing one breaker across the family.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


2-5700-IG1-P10-A3-DD-7A

E-T-A

CIR BRKR THRM 7A 250VAC 50VDC

In Stock: 1392

SUBMIT RFQ