Choose your country or region.

Image may be representation.
See specs for product details.

MU1-B-34-460-1-A21-B-E

In Stock 12406 pcs Reference Price(In US Dollars)
1+
$24.2017
Manufacturer Part Number:
MU1-B-34-460-1-A21-B-E
Manufacturer / Brand
Carling Technologies
Part of Description:
CIRCUIT BREAKER
Datasheets:
Lead Free Status / RoHS Status:
RoHS Compliant
Stock Condition:
New original, 12406 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number MU1-B-34-460-1-A21-B-E
Manufacturer / Brand Carling Technologies
Stock Quantity 12406 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIRCUIT BREAKER
Lead Free Status / RoHS Status: RoHS Compliant
Voltage Rating - DC 80 V
Voltage Rating - AC 250 V
Number of Poles 1
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 6A
Breaker Type Magnetic (Hydraulic Delay)
Approval Agency CSA, TUV, UL
Actuator Type Push to Reset

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can MU1-B-34-460-1-A21-B-E be used in a panel retrofit when the existing breaker has a different trip technology?
MU1-B-34-460-1-A21-B-E uses a magnetic (hydraulic delay) trip mechanism, so a retrofit should first verify whether the original breaker’s time-current behavior is similar. If the old part was thermal, thermal-magnetic, or an electronic protector, the inrush tolerance and trip curve may differ enough to change nuisance-trip behavior or fault protection. For a safe replacement, compare mounting cutout, terminal style, panel depth, reset method, and actual load profile rather than current rating alone.
Is MU1-B-34-460-1-A21-B-E suitable for loads with high inrush current such as motors, transformers, or capacitive power supplies?
MU1-B-34-460-1-A21-B-E can be a practical choice for circuits with short-duration inrush because the hydraulic delay element is typically more tolerant of startup surges than a purely instantaneous device. The actual fit depends on the inrush magnitude, duration, ambient temperature, and how often the load starts. For motor or PSU applications, check the load’s startup waveform against the breaker’s trip curve to avoid repeated nuisance resets.
How should MU1-B-34-460-1-A21-B-E be selected for a 250 VAC industrial panel with mixed loads?
MU1-B-34-460-1-A21-B-E is rated for 250 VAC, but the circuit should be evaluated for both steady-state current and the worst-case fault current available from the source. In mixed-load panels, the breaker may see different stress from resistive, inductive, and capacitive branches. Confirm that the upstream supply can clear faults within the breaker’s interrupting capability and that downstream wiring insulation and terminal spacing are also suitable for the system voltage.
Can MU1-B-34-460-1-A21-B-E be used on an 80 VDC control or battery circuit?
MU1-B-34-460-1-A21-B-E is specified for 80 VDC, which makes it applicable for many control and battery-fed systems, provided the polarity, fault level, and grounding scheme are understood. DC interruption is generally more demanding than AC because the arc does not self-extinguish at a zero crossing, so the expected short-circuit current and wiring protection strategy should be checked carefully. If the circuit has high available DC fault current, coordinate this breaker with upstream protection.
What design checks are needed when using MU1-B-34-460-1-A21-B-E as the only protection for a control board?
When MU1-B-34-460-1-A21-B-E is used as the sole branch protection, the conductor gauge, PCB trace protection, connector ratings, and enclosure temperature rise all need to be considered together. A 6A breaker does not automatically protect every downstream component if the wiring or connectors are rated lower, or if the fault path is limited. Engineers usually verify overload behavior, short-circuit coordination, and whether any downstream semiconductors need faster protection.
Is MU1-B-34-460-1-A21-B-E appropriate for equipment that needs frequent manual reset after faults?
MU1-B-34-460-1-A21-B-E uses a push-to-reset actuator, which suits equipment where operators can visually inspect and manually restore the circuit after a trip. In applications with repeated fault events, it is useful to determine whether the root cause is transient overload, wiring damage, or a failing load, because repeated resetting without correction can mask an unresolved issue. For remote or automated recovery, a manual reset breaker like MU1-B-34-460-1-A21-B-E may require extra control logic or operator access.
What should be checked before replacing another brand’s panel-mount breaker with MU1-B-34-460-1-A21-B-E?
Before replacing another brand with MU1-B-34-460-1-A21-B-E, confirm panel cutout dimensions, bezel geometry, mounting depth, terminal orientation, and the exact trip characteristics. Even when electrical ratings appear similar, small differences in actuator travel or case shape can affect panel fit and wiring clearance. It is also useful to compare agency approvals if the equipment must stay compliant after the substitution.
Does MU1-B-34-460-1-A21-B-E work well in environments with vibration or repeated mechanical shock?
MU1-B-34-460-1-A21-B-E is a panel-mount breaker, so mechanical robustness depends on the quality of the panel fit, the wiring strain relief, and the amount of vibration in the final assembly. In higher-vibration environments, installers typically check for secure nut torque, terminal retention, and whether the actuator remains accessible after panel flexing. If the equipment is subject to sustained shock, the whole mounting stack should be validated rather than assuming the breaker alone will carry the load.
How do I decide if MU1-B-34-460-1-A21-B-E is the right choice for replacing a fuse?
MU1-B-34-460-1-A21-B-E may be a good fuse replacement when the goal is manual reset, easier maintenance, and visible trip indication through the actuator position. The main trade-off is that a breaker can have a different response to high fault currents than a fuse, especially for semiconductor protection or very fast fault isolation. For replacement projects, compare let-through energy, fault clearing speed, and any required certifications for the end product.
Can MU1-B-34-460-1-A21-B-E be used in equipment that must meet UL, CSA, or TUV approval requirements?
MU1-B-34-460-1-A21-B-E carries UL, CSA, and TUV approvals, which helps when the finished equipment needs recognized component compliance. The final system still needs to meet the relevant end-product standard, including enclosure spacing, wire ratings, temperature rise, and branch circuit coordination. In practice, approved component status simplifies documentation, but it does not replace full system-level validation.
What are the practical differences between MU1-B-34-460-1-A21-B-E and an electronic circuit protector for industrial control panels?
MU1-B-34-460-1-A21-B-E is a magnetic (hydraulic delay) breaker, so its behavior is set by electromechanical trip characteristics rather than programmable logic. Compared with electronic protectors, it usually offers simpler integration and fewer auxiliary requirements, but it does not provide adjustable thresholds, communication, or detailed diagnostics. If the application needs logging, remote trip, or selective coordination across multiple branches, an electronic solution may be easier to engineer.
Is MU1-B-34-460-1-A21-B-E suitable for outdoor or high-temperature installations?
MU1-B-34-460-1-A21-B-E can be used in demanding environments if the enclosure, ambient temperature, and derating conditions remain within the breaker’s operating envelope. Hydraulic delay mechanisms can shift their trip behavior with temperature, so hot-panel conditions may cause earlier tripping than a room-temperature bench test suggests. For outdoor systems, the breaker should be protected from moisture, UV exposure, and condensation, and the panel thermal design should be reviewed.
What should be considered when selecting MU1-B-34-460-1-A21-B-E for a 6A branch on a power distribution panel?
MU1-B-34-460-1-A21-B-E at 6A is typically chosen when the branch load, wiring, and connectors are all consistent with that current level. Engineers usually check continuous load margin, startup current, ambient heating, and whether neighboring breakers or hot components raise the internal panel temperature. If the load is close to 6A for long periods, derating or a higher-rated branch design may be evaluated to reduce nuisance trips.
Are there any special wiring or polarity considerations for MU1-B-34-460-1-A21-B-E on DC circuits?
MU1-B-34-460-1-A21-B-E is rated for DC use, so wiring should be verified against the system’s grounding and fault architecture. Some DC systems place the breaker on the positive side, while others use different topology depending on the source and safety strategy. Because DC arcs are harder to extinguish, engineers should also confirm conductor routing, terminal tightness, and any required upstream disconnecting means.
What replacement alternatives should be evaluated if MU1-B-34-460-1-A21-B-E is unavailable?
If MU1-B-34-460-1-A21-B-E is unavailable, the best alternatives are usually other Carling Technologies M-series parts or equivalent panel-mount breakers with the same current rating, voltage ratings, pole count, reset style, and cutout compatibility. Practical differences often appear in actuator style, trip curve, approvals, and physical depth, which can affect both safety and panel redesign effort. A candidate replacement should be reviewed against the original load profile and installation constraints, not just the catalog amperage.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


MU1-B-34-460-1-A21-B-E

Carling Technologies

CIRCUIT BREAKER

In Stock: 12406

Submit RFQ