Choose your country or region.

Image may be representation.
See specs for product details.

MF2-B-34-610-1-KD4-2-C

In Stock 651 pcs Reference Price(In US Dollars)
2+
$51.5379
Manufacturer Part Number:
MF2-B-34-610-1-KD4-2-C
Manufacturer / Brand
Carling Technologies
Part of Description:
CIRCUIT BREAKER
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 651 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number MF2-B-34-610-1-KD4-2-C
Manufacturer / Brand Carling Technologies
Stock Quantity 651 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIRCUIT BREAKER
Lead Free Status / RoHS Status: ROHS3 Compliant
Voltage Rating - DC 80 V
Voltage Rating - AC 250 V
Series M
Package Bulk
Number of Poles 2
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Illumination Amber
Current Rating (Amps) 10A
Breaker Type Magnetic (Hydraulic Delay)
Approval Agency CCC, CSA, UL1077
Actuator Type Rocker

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: PayPal@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can the MF2-B-34-610-1-KD4-2-C be used in place of a standard thermal breaker when the load has high inrush current or motor start-up peaks?
MF2-B-34-610-1-KD4-2-C uses a magnetic (hydraulic delay) trip mechanism, which typically tolerates short-duration inrush better than a purely thermal device. That makes MF2-B-34-610-1-KD4-2-C a practical choice for circuits with transformer magnetizing current, capacitive loads, or motor starting peaks, provided the steady-state current and ambient conditions are still within the intended trip profile. For replacement work, engineers usually verify the actual inrush waveform and duration rather than relying only on the nominal 10A rating.
Is MF2-B-34-610-1-KD4-2-C suitable for 120/230 VAC equipment, and what should be checked before using it in mains applications?
MF2-B-34-610-1-KD4-2-C is rated for up to 250 V AC, so it can be applied in many 120 VAC and 230 VAC designs if the overall system insulation, wiring, and clearance/creepage layout are also suitable. In mains equipment, designers usually confirm that the breaker’s panel mounting, conductor gauge, upstream protection, and enclosure ratings match the installation environment. If the circuit includes high surge energy or nonstandard neutral/line arrangements, coordination with the rest of the protection scheme should be reviewed.
Can MF2-B-34-610-1-KD4-2-C be used on 24 VDC systems, or is there a DC limitation to consider?
MF2-B-34-610-1-KD4-2-C is rated to 80 V DC, so 24 VDC and 48 VDC control or distribution systems are generally within its voltage range. For DC use, the more practical checks are interrupting behavior, fault current available from the supply, and whether the circuit wiring and downstream loads can tolerate the breaker’s trip characteristics. In battery-backed systems, engineers also verify that the source can deliver enough fault current for the breaker to clear reliably.
When replacing another panel-mount breaker, what mechanical details should be matched to MF2-B-34-610-1-KD4-2-C?
For a swap to MF2-B-34-610-1-KD4-2-C, the key mechanical checks are panel cutout dimensions, mounting style, front-panel depth, actuator travel, and terminal orientation. Even when the electrical ratings look compatible, small differences in bezel size or terminal spacing can affect harness routing and enclosure fit. If the old part used a different actuator profile, the user-facing appearance and operator feel may also change.
Does MF2-B-34-610-1-KD4-2-C work as a direct replacement for a different brand 10A rocker breaker?
MF2-B-34-610-1-KD4-2-C may be a replacement candidate for other 10A panel breakers, but a direct drop-in depends on the cutout, mounting footprint, terminal style, trip curve, and whether the original part was single-pole or two-pole. Two breakers with the same current rating can behave differently under overload and inrush conditions, so engineers usually compare trip mechanism, reset behavior, and regulatory approvals before approving substitution. If the original device had a different pole count or illumination option, the wiring and panel labeling may need updates.
What does the 2-pole configuration of MF2-B-34-610-1-KD4-2-C mean for integration into a power path?
The 2-pole arrangement in MF2-B-34-610-1-KD4-2-C is typically used when both conductors need to be interrupted together, or when a system architecture calls for simultaneous disconnect of two lines. That can be useful in certain AC circuits, bipolar DC applications, or designs where isolation expectations require both paths to open together. Before using MF2-B-34-610-1-KD4-2-C, designers usually confirm whether both poles are intended to switch live conductors or whether one pole should remain unswitched for the application.
Can MF2-B-34-610-1-KD4-2-C be used in industrial equipment exposed to vibration or frequent switching?
MF2-B-34-610-1-KD4-2-C is a panel-mount rocker breaker, so it is often used in control cabinets and equipment panels where operator access is needed. For vibration-prone installations, the real consideration is not only the breaker itself but also panel rigidity, connector retention, and wire strain relief. If the equipment sees frequent cycling, engineers generally check actuator wear, contact loading, and whether the enclosure layout prevents accidental operation or repeated mechanical stress.
Is the amber illumination on MF2-B-34-610-1-KD4-2-C suitable for dark control panels, and what should be checked before design-in?
The amber illumination on MF2-B-34-610-1-KD4-2-C can improve operator visibility in low-light panels, but the illumination circuit should be reviewed separately because the nominal illumination voltage is not specified in the part summary. In practice, designers confirm the required lamp or LED drive conditions, whether the indicator is tied to switched load status or panel supply, and how brightness appears through the final lens color and enclosure material. If panel labeling and color coding already carry operational meaning, the amber actuator should be checked for consistency with the human-machine interface.
How should MF2-B-34-610-1-KD4-2-C be selected for a battery-powered system with limited fault current?
In battery-powered systems, MF2-B-34-610-1-KD4-2-C can be appropriate if the available fault current is sufficient for the breaker to operate as intended under short-circuit conditions. Some low-voltage battery systems produce high fault current, while others with long cable runs or current-limited electronics may not. Engineers usually evaluate worst-case loop resistance, battery internal resistance, and protective coordination so MF2-B-34-610-1-KD4-2-C clears faults without nuisance behavior.
What should be checked if MF2-B-34-610-1-KD4-2-C is being considered for a retrofit where the old breaker had a different trip behavior?
When retrofitting with MF2-B-34-610-1-KD4-2-C, the most common mismatch is trip behavior rather than nominal amp rating. A hydraulic-delay magnetic breaker can hold brief overloads differently from a thermal breaker, so a retrofit may change whether startup transients pass or nuisance trips disappear. Engineers typically compare operating curves, ambient derating, and load profiles to ensure MF2-B-34-610-1-KD4-2-C preserves the intended protection coordination.
Are the CCC, CSA, and UL1077 approvals on MF2-B-34-610-1-KD4-2-C enough for every end equipment certification path?
MF2-B-34-610-1-KD4-2-C carries CCC, CSA, and UL1077 recognition, which helps in many compliance workflows, but final equipment approval still depends on the complete assembly. The enclosure, wiring, spacing, temperature rise, and fault testing can all affect the end product’s certification outcome. For global programs, teams usually map MF2-B-34-610-1-KD4-2-C’s recognition to the target standard set early so there are fewer surprises during system-level testing.
Is MF2-B-34-610-1-KD4-2-C appropriate for equipment that runs continuously at elevated ambient temperature?
MF2-B-34-610-1-KD4-2-C can be used in continuous-duty equipment, but ambient temperature affects the operating margin of many hydraulic-delay magnetic breakers. In a warm enclosure, the same 10A load may behave differently than on an open bench because heat buildup can shift trip timing and reduce headroom. For long-life industrial use, designers usually validate the breaker with the actual enclosure temperature, airflow, and nearby heat sources rather than relying only on room-temperature assumptions.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


MF2-B-34-610-1-KD4-2-C

Carling Technologies

CIRCUIT BREAKER

In Stock: 651

SUBMIT RFQ