Choose your country or region.

Image may be representation.
See specs for product details.

MD2-B-34-620-2-A46-B-C

In Stock 618 pcs Reference Price(In US Dollars)
3+
$48.9942
Manufacturer Part Number:
MD2-B-34-620-2-A46-B-C
Manufacturer / Brand
Carling Technologies
Part of Description:
CIRCUIT BREAKER
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 618 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number MD2-B-34-620-2-A46-B-C
Manufacturer / Brand Carling Technologies
Stock Quantity 618 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIRCUIT BREAKER
Lead Free Status / RoHS Status: ROHS3 Compliant
Voltage Rating - DC 80 V
Voltage Rating - AC 250 V
Series M
Package Bulk
Number of Poles 2
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 20A
Breaker Type Magnetic (Hydraulic Delay)
Approval Agency CCC, CSA, UL1077
Actuator Type Rocker

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can the MD2-B-34-620-2-A46-B-C be used as a direct replacement for another 2-pole panel-mount breaker in an existing control panel?
The MD2-B-34-620-2-A46-B-C can be considered for replacement when the existing cutout, rocker actuator style, panel thickness, and wiring arrangement match the M-series form factor. Because it is a 2-pole magnetic hydraulic-delay breaker with a 20A rating, the replacement should also be checked against the original load profile and trip behavior, since a delayed-trip breaker may behave differently from a thermal or thermal-magnetic device during inrush or short-duration overloads. If the previous part had different trip curves, actuation feel, or terminal layout, the panel may need revalidation before reuse.
Is the MD2-B-34-620-2-A46-B-C suitable for circuits with high inrush current, such as motors, power supplies, or transformer inputs?
The MD2-B-34-620-2-A46-B-C uses a magnetic hydraulic-delay mechanism, which is often selected when the load has short inrush peaks that should not cause nuisance tripping. That said, suitability depends on the specific inrush magnitude, duration, ambient temperature, and duty cycle of the load. Engineers typically verify the startup waveform against the breaker’s trip timing behavior and confirm that repeated inrush events will not accelerate wear or cause intermittent trips in the finished system.
What should I check before using the MD2-B-34-620-2-A46-B-C in a 250 VAC or 80 VDC application?
With the MD2-B-34-620-2-A46-B-C, the supply must stay within the stated AC and DC voltage limits for the intended interrupting and protection function. For DC use, contact arcing and interruption characteristics are more demanding than AC, so the installation should verify that the system’s fault current, wiring length, and downstream capacitance do not exceed what the breaker is intended to interrupt. If the load is inductive or the DC source can deliver very high fault current, additional protection coordination may be needed.
Does the MD2-B-34-620-2-A46-B-C work well as a panel-mounted main branch protector in industrial equipment?
The MD2-B-34-620-2-A46-B-C is a panel-mount breaker, so it fits applications where an operator-accessible reset and branch protection are useful. It is commonly evaluated for industrial panels, test equipment, and power distribution subassemblies when the enclosure provides proper spacing, conductor sizing, and fault-energy coordination. For a main incoming protector, the designer should confirm the upstream protection scheme, available fault current, and whether a breaker with a different interrupting architecture is needed.
How do I know if the MD2-B-34-620-2-A46-B-C is appropriate for replacing a thermal breaker without changing nuisance-trip behavior?
The MD2-B-34-620-2-A46-B-C may not mirror the time-current curve of a thermal device, because magnetic hydraulic-delay breakers often respond differently to sustained overloads and transient peaks. When replacing a thermal breaker, compare trip curves, ambient derating, and reset behavior under repeated load cycling. In practice, a direct swap is usually validated by testing the actual load profile rather than relying only on the nominal current rating.
Can the MD2-B-34-620-2-A46-B-C be used in equipment that requires two poles to open simultaneously?
Yes, the MD2-B-34-620-2-A46-B-C is a 2-pole breaker, so it is suitable where both conductors must be interrupted together for functional isolation or service convenience. Designers still need to confirm whether the circuit requires true simultaneous disconnection of line and neutral, two energized DC conductors, or another wiring topology. The overall isolation scheme should also consider spacing, conductor marking, and any upstream disconnect requirements in the target standard.
What are the main design considerations when selecting the MD2-B-34-620-2-A46-B-C for a DC control cabinet?
For DC control cabinets, the MD2-B-34-620-2-A46-B-C should be assessed for voltage margin, fault-clearing capability, and how the load’s inductance affects interruption. DC circuits do not benefit from zero-crossing current extinction, so interruption stress can be higher than in AC systems. Designers typically check conductor gauge, enclosure temperature rise, and whether suppression devices are needed for coils, solenoids, or motor loads connected downstream.
Is the MD2-B-34-620-2-A46-B-C a good choice for retrofit projects where panel space is limited?
The MD2-B-34-620-2-A46-B-C can be a practical retrofit option if the existing panel cutout and depth clearances align with the rocker-style panel-mount format. Retrofit success usually depends on matching not only the external dimensions but also terminal accessibility, wire bend radius, and front-panel clearance behind labels or overlays. If the old breaker used a different mounting family, the panel may need mechanical adaptation to preserve fit and serviceability.
What should I verify if I want to use the MD2-B-34-620-2-A46-B-C in a product that will run in hot industrial environments?
In elevated ambient temperatures, the MD2-B-34-620-2-A46-B-C may reach its trip thresholds sooner than at room temperature, depending on the surrounding enclosure and adjacent heat sources. Engineers usually check derating effects, panel ventilation, and the thermal load from nearby components such as power supplies, drives, or relays. If the breaker is placed in a sealed cabinet, testing at worst-case temperature is a common way to confirm stable operation over the intended duty cycle.
How does the MD2-B-34-620-2-A46-B-C compare with replacing a breaker from another brand such as Eaton, Schneider, or Siemens?
The MD2-B-34-620-2-A46-B-C may not be a drop-in equivalent to many Eaton, Schneider, or Siemens devices because panel cutout geometry, actuator style, trip curve, and approvals can differ even when current ratings appear similar. When considering a cross-brand replacement, the engineer should compare physical fit, pole count, reset mechanism, and the behavior under inrush and fault conditions. If the original part served as both a protective device and a user interface element, the front-panel appearance and operating force may also need review.
Does the MD2-B-34-620-2-A46-B-C need any special wiring or terminal checks before installation?
With the MD2-B-34-620-2-A46-B-C, the installer should confirm conductor size, lug compatibility, terminal torque, and strain relief so the connection remains stable under vibration and thermal cycling. Since it is a 2-pole breaker, correct conductor pairing and polarity identification are also important in DC systems. For long-term reliability, many designers perform a pull check and verify that wire routing does not create mechanical stress on the terminals or the rocker body.
Is the MD2-B-34-620-2-A46-B-C suitable for replacing a fuse-holder arrangement?
The MD2-B-34-620-2-A46-B-C can replace a fuse-holder arrangement when the system benefits from resettable protection and panel-accessible operation. The trade-off is that the breaker’s trip behavior, coordination with upstream protection, and interruption performance must still fit the fault profile. In some designs, a fuse clears faster under severe fault conditions, so a replacement should be validated against the available short-circuit current and any downstream semiconductor sensitivity.
Can the MD2-B-34-620-2-A46-B-C be used in equipment that needs CE-marked components?
The MD2-B-34-620-2-A46-B-C carries CCC, CSA, and UL1077 approvals, which may support compliance planning in certain markets, but CE marking depends on the final equipment and applicable directives rather than the breaker alone. Designers should verify the complete bill of materials, enclosure, wiring, and test data for the target region. If the equipment will be sold internationally, the approval set should be reviewed alongside the system-level safety assessment.
What are the practical differences between the MD2-B-34-620-2-A46-B-C and a single-pole breaker in the same 20A range?
The MD2-B-34-620-2-A46-B-C opens two poles together, which changes how the protected circuit is isolated and how faults are cleared compared with a single-pole device. That can matter in AC systems where both line and neutral need to be interrupted, or in DC systems where both conductors are live. A single-pole breaker may save space, but the two-pole configuration can simplify servicing and improve disconnection architecture when the system design calls for it.
What reliability checks are sensible if the MD2-B-34-620-2-A46-B-C will be used in a long-life industrial product?
For long-life use, the MD2-B-34-620-2-A46-B-C should be evaluated for contact cycling, vibration exposure, environmental sealing at the panel interface, and repeated manual operation over the product’s life. Designers often review the operating profile to see whether the breaker will be switched frequently or mainly used as an occasional protection device. If the enclosure is exposed to dust, humidity, or field service conditions, periodic inspection of the panel mount and terminal condition can help maintain consistent performance.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


MD2-B-34-620-2-A46-B-C

Carling Technologies

CIRCUIT BREAKER

In Stock: 618

SUBMIT RFQ