Choose your country or region.

Image may be representation.
See specs for product details.

EA2-B0-24-630-22A-DF

In Stock 264 pcs Reference Price(In US Dollars)
1+
$121.0117
Manufacturer Part Number:
EA2-B0-24-630-22A-DF
Manufacturer / Brand
Carling Technologies
Part of Description:
CIRCUIT BREAKER
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 264 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number EA2-B0-24-630-22A-DF
Manufacturer / Brand Carling Technologies
Stock Quantity 264 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIRCUIT BREAKER
Lead Free Status / RoHS Status: ROHS3 Compliant
Voltage Rating - DC 125 V
Voltage Rating - AC 240 V
Series E
Package Bulk
Number of Poles 2
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 30A
Breaker Type Magnetic (Hydraulic Delay)
Approval Agency CCC, CSA, UL489, VDE
Actuator Type Lever

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: PayPal@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can EA2-B0-24-630-22A-DF be used as a direct replacement in an existing panel that previously used a different 30A two-pole breaker?
EA2-B0-24-630-22A-DF can be used as a replacement only if the existing panel cutout, mounting method, terminal spacing, lever clearance, and two-pole wiring arrangement match the Carling Technologies E-series format. In retrofit work, the main checks are mechanical fit, conductor termination style, and whether the original breaker used the same magnetic (hydraulic delay) trip behavior. If the old part was thermal-only or had a different trip curve, EA2-B0-24-630-22A-DF may change nuisance-trip behavior during motor starting or inrush events.
Is EA2-B0-24-630-22A-DF suitable for circuits with motor inrush or transformer startup current?
EA2-B0-24-630-22A-DF uses a magnetic (hydraulic delay) mechanism, which is generally more tolerant of short inrush pulses than many fast-acting protection devices. That makes the Carling Technologies EA2-B0-24-630-22A-DF a reasonable candidate for loads with brief startup surges, such as small motors, control transformers, or power supplies. The actual fit still depends on the magnitude and duration of the inrush current, ambient temperature, and whether the protected load’s steady-state current stays within the 30A rating.
How should I verify that EA2-B0-24-630-22A-DF is appropriate for a 240 V AC panel design?
EA2-B0-24-630-22A-DF is rated for 240 V AC, so it can be used in 240 V AC distribution or equipment panels when the system voltage and fault conditions are within the breaker’s certified application range. For engineering selection, verify not only nominal voltage but also interrupting duty, conductor insulation rating, enclosure spacing, and the available short-circuit current in the panel. The Carling Technologies EA2-B0-24-630-22A-DF should be selected in a way that the installation remains compatible with the applicable end-equipment standard and branch protection scheme.
Can EA2-B0-24-630-22A-DF be used on 125 V DC circuits, and what design issues should I check first?
EA2-B0-24-630-22A-DF is rated for 125 V DC, so it may be used in DC distribution where the load current, fault current, and wiring configuration match the breaker’s DC rating. With DC protection, arc interruption behavior is more demanding than with AC, so engineers should confirm polarity, wiring layout, and available fault energy. The Carling Technologies EA2-B0-24-630-22A-DF should also be evaluated for the specific load profile, because inductive loads and battery-backed systems can create higher stress during interruption.
What should I consider when using EA2-B0-24-630-22A-DF in an industrial enclosure with elevated ambient temperature?
Ambient temperature can shift trip behavior and affect long-term thermal loading around the panel, even with a magnetic (hydraulic delay) device like EA2-B0-24-630-22A-DF. In an enclosed cabinet, nearby heat sources, reduced airflow, and conductor bundling can raise operating temperature and influence protection margin. For the Carling Technologies EA2-B0-24-630-22A-DF, it is good practice to review derating guidance, terminal temperature rise, and cable ampacity so the breaker and connected conductors remain coordinated under worst-case conditions.
Is EA2-B0-24-630-22A-DF a good choice for replacing a fuse in a control panel?
EA2-B0-24-630-22A-DF can replace a fuse only when the circuit needs manual reset capability and the downstream protection coordination still works as intended. Compared with a fuse, the Carling Technologies EA2-B0-24-630-22A-DF offers resettable protection, but the trip response and fault-clearing characteristics are different. In a retrofit, engineers should confirm that the breaker’s protection curve is compatible with the load and that the circuit does not require the very high current-limiting behavior some fuses provide.
How do I determine whether EA2-B0-24-630-22A-DF is compatible with a two-pole isolation requirement?
EA2-B0-24-630-22A-DF is a two-pole breaker, so it can support designs that require simultaneous interruption of two conductors. That is useful for line-to-line AC circuits or DC systems where both poles must be disconnected together for servicing or safety logic. When applying the Carling Technologies EA2-B0-24-630-22A-DF, verify how the poles are intended to be used in your standard, whether both poles are carrying current, and whether the panel needs a lockout or visible-open condition beyond the lever indication.
What should I check before choosing EA2-B0-24-630-22A-DF for a panel-mount upgrade?
For a panel-mount device like EA2-B0-24-630-22A-DF, the critical checks are cutout dimensions, panel thickness, mounting hardware, behind-panel clearance, and conductor routing. The lever actuator also needs enough front-panel space for full travel and labeling. With the Carling Technologies EA2-B0-24-630-22A-DF, it is also worth confirming whether the new installation needs the same sealing, ingress protection, or cosmetic bezel arrangement as the original design.
Are there trade-offs if I use EA2-B0-24-630-22A-DF in a design that previously depended on a thermal breaker?
Yes. EA2-B0-24-630-22A-DF uses magnetic (hydraulic delay) trip behavior rather than a purely thermal mechanism, so the timing and response to overloads can differ. In practice, this can reduce nuisance trips on short surges while also changing how slowly sustained overloads are handled compared with a thermal unit. When migrating to the Carling Technologies EA2-B0-24-630-22A-DF, engineers should review the load profile, conductor protection strategy, and any certification or test data that referenced the original thermal breaker.
Can EA2-B0-24-630-22A-DF be used in equipment that needs front-panel user reset access?
EA2-B0-24-630-22A-DF includes a lever actuator, which makes it suitable for front-panel reset and manual operation in equipment that is intended to be serviced by operators or maintenance staff. The Carling Technologies EA2-B0-24-630-22A-DF should be used only where the lever location, mechanical travel, and labeling clearly indicate the protected circuit. In applications with frequent operator interaction, it is also useful to consider whether unintended reset after a fault is acceptable for the machine’s safety logic.
What are the main reliability considerations for long-term industrial use of EA2-B0-24-630-22A-DF?
For long-term industrial operation, EA2-B0-24-630-22A-DF should be evaluated for vibration, panel shock, temperature cycling, contact resistance over time, and the quality of conductor termination. Mechanical levers can remain dependable, but environment and installation quality still influence service life. With the Carling Technologies EA2-B0-24-630-22A-DF, periodic inspection of terminal torque, discoloration, and abnormal heating around the breaker helps catch installation issues before they affect uptime.
If I am looking for alternatives to EA2-B0-24-630-22A-DF, what should I compare besides the 30A rating?
When comparing alternatives to EA2-B0-24-630-22A-DF, match the mounting footprint, poles, AC/DC voltage ratings, trip mechanism, actuator style, approvals, and the intended application profile. A part with the same 30A rating may still behave differently under inrush, fault clearing, or repeated cycling. For a replacement near the Carling Technologies EA2-B0-24-630-22A-DF, look for similar E-series mechanical compatibility or be prepared to revise the panel cutout, wiring, and certification documentation.
Does EA2-B0-24-630-22A-DF require any special considerations when used in a UL489 listed design?
EA2-B0-24-630-22A-DF carries UL489 approval, so it can fit into designs that are built around UL-listed branch or supplementary protection requirements when the rest of the system is also compliant. Even with the Carling Technologies EA2-B0-24-630-22A-DF, the complete assembly still needs coordination of conductors, enclosure, spacing, and load type. Engineers should confirm whether the final equipment uses the breaker as branch protection, supplement protection, or part of a larger protected circuit architecture.
Is EA2-B0-24-630-22A-DF appropriate for equipment that operates continuously near 30A?
EA2-B0-24-630-22A-DF can be used near its 30A rating only when the application’s continuous duty, ambient conditions, and enclosure heat rise are carefully reviewed. In real panels, operating continuously at the nominal rating can leave little margin for temperature rise, conductor bundling, or transient loading. For the Carling Technologies EA2-B0-24-630-22A-DF, it is common to validate the actual steady-state load and consider whether the design would benefit from additional headroom.
What should I verify if I want to use EA2-B0-24-630-22A-DF in a multi-brand control cabinet?
In a mixed-vendor cabinet, EA2-B0-24-630-22A-DF should be checked against neighboring devices for physical spacing, lever access, heat contribution, wiring direction, and labeling conventions. Different brands can have different panel cutout standards, even when the current and voltage ratings look similar. For the Carling Technologies EA2-B0-24-630-22A-DF, the practical integration step is confirming that the breaker’s footprint and operating clearances do not interfere with adjacent modules, wire ducts, or door components.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


EA2-B0-24-630-22A-DF

Carling Technologies

CIRCUIT BREAKER

In Stock: 264

SUBMIT RFQ