Choose your country or region.

Image may be representation.
See specs for product details.

CLB-203-27E6B-W-D/20

In Stock 11979 pcs Reference Price(In US Dollars)
500+
$2.6274
Manufacturer Part Number:
CLB-203-27E6B-W-D/20
Manufacturer / Brand
Carling Technologies
Part of Description:
CIRCUIT BREAKER
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 11979 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number CLB-203-27E6B-W-D/20
Manufacturer / Brand Carling Technologies
Stock Quantity 11979 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIRCUIT BREAKER
Lead Free Status / RoHS Status: ROHS3 Compliant
Voltage Rating - DC 32 V
Voltage Rating - AC 250 V
Series CLB
Package Bulk
Number of Poles 1
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 20A
Breaker Type Thermal
Approval Agency CE, cUL, TUV, UL1077, UL1500
Actuator Type Push to Reset

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can I use CLB-203-27E6B-W-D/20 as a branch-circuit protector for a 24 V DC industrial panel, or is it better suited as equipment-level protection?
CLB-203-27E6B-W-D/20 is a thermal circuit breaker rated for 32 V DC and 250 V AC, so it can be used in many 24 V DC equipment-level applications. In practice, it is typically used to protect a load or internal wiring segment rather than to replace upstream system protection. For a 24 V DC panel, verify that the expected fault current is within the breaker’s interrupting capability and that the protected wiring gauge matches the 20 A rating. If the panel includes large capacitive loads, motor inrush, or DC bus energy, coordinate this breaker with upstream fusing or source protection so nuisance trips or inadequate fault clearing do not occur.
What wiring and load considerations should I check before selecting CLB-203-27E6B-W-D/20 for a 20 A panel-mount design?
With CLB-203-27E6B-W-D/20, the main checks are conductor ampacity, terminal temperature rise, load inrush, and continuous duty. A 20 A thermal breaker can carry substantial load, but sustained operation close to rating depends on enclosure temperature and airflow. If the application has bundled wiring, elevated ambient temperature, or continuous load near 20 A, the effective trip behavior can shift. For design-in, confirm the wire insulation class, terminal ratings, and any downstream connector limits so the breaker does not become the only 20 A-rated element in the power path.
Is CLB-203-27E6B-W-D/20 a good choice for inductive loads such as motors, solenoids, or transformers?
CLB-203-27E6B-W-D/20 can work with inductive loads, but thermal breakers respond to heating rather than instantaneous magnetic fault detection. That means motor start current, transformer energization, or solenoid pull-in current may cause delayed tripping if the load profile is repetitive or high duty cycle. For designs with frequent starts or high inrush, engineers usually validate the breaker against the full startup waveform, not just steady-state current. If the load has large inrush peaks, a breaker with a different trip characteristic or separate inrush management may fit better.
How should I compare CLB-203-27E6B-W-D/20 with substitutes like CBW57-PF-20A-5X or CBW57-PL-20A-5X during a redesign?
When comparing CLB-203-27E6B-W-D/20 with substitutes such as CBW57-PF-20A-5X or CBW57-PL-20A-5X, check more than current rating. Practical differences often include panel cutout geometry, actuator feel, reset method, mechanical envelope, terminal style, and agency approvals. Even if the replacement is also 20 A, the trip curve and reset behavior can affect field service and nuisance-trip rates. For a redesign, confirm that the substitute matches the panel thickness range, mounting hardware, clearance behind the panel, and any required environmental approvals for the end product.
Can CLB-203-27E6B-W-D/20 replace a fuse in an existing design without changing the rest of the circuit?
In some systems, CLB-203-27E6B-W-D/20 can replace a fuse when manual reset and visible trip indication are desired, but the electrical behavior is not identical to a fuse. A thermal breaker typically has different time-current characteristics, and it resets after the fault is removed. That changes fault recovery, maintenance procedures, and coordination with upstream protection. If the original design relied on a fuse’s very fast clearing for semiconductor protection, CLB-203-27E6B-W-D/20 may not be a drop-in replacement without reassessing component stress and fault energy.
What panel mounting and mechanical clearance issues should I check for CLB-203-27E6B-W-D/20?
For CLB-203-27E6B-W-D/20, confirm the front-panel cutout, mounting retention method, and rear clearance before finalizing the enclosure. Push-to-reset breakers need enough access for the actuator to travel fully and enough space behind the panel for terminals, insulation sleeves, and conductor bend radius. In crowded enclosures, nearby cable ducts or brackets can interfere with reset action or make service access difficult. Mechanical vibration is another concern; verify that the panel mount maintains consistent retention under transport and field vibration conditions.
Is CLB-203-27E6B-W-D/20 suitable for marine, vehicle, or other vibration-prone environments?
CLB-203-27E6B-W-D/20 may be suitable in vibration-prone environments if the panel mounting, conductor strain relief, and enclosure design are controlled carefully. Because it is a push-to-reset thermal breaker, repeated vibration can affect both mechanical retention and connection integrity at the terminals. In marine or vehicle systems, temperature swings and moisture exposure also matter. Engineers usually validate terminal security, corrosion resistance of surrounding hardware, and accessibility for reset when equipment is installed in confined or moving platforms.
How does ambient temperature affect the trip behavior of CLB-203-27E6B-W-D/20 in industrial enclosures?
As a thermal breaker, CLB-203-27E6B-W-D/20 is influenced by ambient temperature and self-heating from adjacent components. In a hot enclosure, it can trip sooner than in a cool open-air setup, especially if the current is near 20 A for long periods. If the breaker is placed next to power supplies, resistors, or heat sinks, thermal coupling can further shift its behavior. For stable operation, keep sufficient spacing from hot components and validate the assembly at the worst-case enclosure temperature you expect in service.
Does CLB-203-27E6B-W-D/20 provide the same protection behavior as a magnetic circuit breaker?
CLB-203-27E6B-W-D/20 is a thermal breaker, so its response is based on heat buildup rather than a magnetic instantaneous trip mechanism. That means it generally responds more gradually to overloads and may not clear certain short-duration high fault currents the same way a magnetic breaker would. If your design needs very fast response to short circuits, especially to protect sensitive semiconductors or thin conductors, confirm that upstream protection and the source impedance are adequate. For overload protection in moderate-power equipment, the thermal behavior can be a practical fit.
What are the main trade-offs when choosing CLB-203-27E6B-W-D/20 over another 20 A panel-mount breaker?
With CLB-203-27E6B-W-D/20, the trade-offs usually center on reset style, certification set, physical format, and trip behavior. A push-to-reset design supports quick field recovery, but it also means operators can restore power without replacing a sacrificial element, so root-cause analysis matters after a trip. Compared with other 20 A panel-mount breakers, the exact actuator geometry, enclosure fit, and hold characteristics can vary enough to affect the final user experience and service procedure. It is common to compare not only electrical ratings but also the system workflow after a fault.
Can CLB-203-27E6B-W-D/20 be used on 250 V AC mains, and what should I verify first?
CLB-203-27E6B-W-D/20 is rated for 250 V AC, but suitability on mains depends on the full system design, not just the voltage label. Check the available fault current, the required agency approvals for the end product, and the spacing/creepage requirements in the enclosure. Also confirm that the connected load and conductors are appropriate for a 20 A branch at the operating temperature of the system. If the breaker is used in a user-accessible product, verify that the panel design prevents accidental contact with live parts during installation or service.
What reliability checks make sense for CLB-203-27E6B-W-D/20 in long-life equipment?
For CLB-203-27E6B-W-D/20 in long-life equipment, common checks include repeated trip/reset cycling, terminal integrity after thermal cycling, and behavior under elevated ambient temperature. Mechanical wear at the push actuator and any change in contact resistance over time should be evaluated in the actual enclosure. If the product will remain deployed for years with infrequent maintenance, it is also useful to test how the breaker behaves after long idle periods and after exposure to dust, humidity, or contamination that could affect actuation.
Are the approvals on CLB-203-27E6B-W-D/20 enough for UL, CE, or marine-oriented end products?
CLB-203-27E6B-W-D/20 carries CE, cUL, TUV, UL1077, and UL1500 approvals, which helps in many regulated designs, but end-product compliance still depends on the full assembly. UL1077 indicates supplementary protection, so if your application needs branch-circuit protection, you should confirm the system-level standard separately. UL1500 is often relevant in marine contexts, but the final enclosure, wiring, and installation method still have to meet the target standard. In practice, approvals shorten the qualification path, but they do not replace complete product-level compliance review.
If I need a direct replacement for CLB-203-27E6B-W-D/20, what should I match besides the 20 A rating?
For a direct replacement of CLB-203-27E6B-W-D/20, match the mounting footprint, panel thickness compatibility, actuator/reset style, terminal layout, and interruption behavior in addition to the 20 A rating. Also verify whether the replacement has the same agency approvals and environmental ratings, because those can affect downstream certifications and service documentation. Even small differences in body depth or terminal orientation can require harness changes. If the replacement is from another family, test both normal load heating and fault-trip coordination before releasing the change to production.
When would CLB-203-27E6B-W-D/20 not be the best choice for an embedded power supply or PCB-protected subsystem?
CLB-203-27E6B-W-D/20 is a panel-mount breaker, so it is generally not the first choice when protection must be placed directly on a PCB or inside a very compact sealed module. If the design needs very short conductor runs, automated assembly, or protection integrated near sensitive circuitry, a board-level fuse or resettable protector may fit better. It is also less convenient when the user cannot access the front panel for reset. In those cases, the mechanical interface and service workflow can outweigh the convenience of the push-to-reset function.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


CLB-203-27E6B-W-D/20

Carling Technologies

CIRCUIT BREAKER

In Stock: 11979

SUBMIT RFQ