CA3-B0-34-635-431-C

In Stock 1932 pcs Reference Price(In US Dollars)
1+
$180.9028
Manufacturer Part Number:
CA3-B0-34-635-431-C
Manufacturer / Brand
Carling Technologies
Part of Description:
CIRCUIT BREAKER
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 1932 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number CA3-B0-34-635-431-C
Manufacturer / Brand Carling Technologies
Stock Quantity 1932 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIRCUIT BREAKER
Lead Free Status / RoHS Status: ROHS3 Compliant
Voltage Rating - DC 125 V
Voltage Rating - AC 480 V
Series C
Package Bulk
Number of Poles 3
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 35A
Breaker Type Magnetic (Hydraulic Delay)
Approval Agency CCC, CSA, UL
Actuator Type Lever

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

What are the key integration constraints when panel mounting the CA3-B0-34-635-431-C 3-pole circuit breaker in a control cabinet with mixed AC and DC circuits?
The CA3-B0-34-635-431-C is a panel mount lever-actuated breaker rated for 480 V AC and 125 V DC. When integrating across mixed voltages, designers typically assign the three poles to separate phases or combine for higher voltage applications while observing the per-pole voltage limits. Adequate clearance for the lever actuator and panel cutout dimensions must be provided, along with consideration for the hydraulic delay mechanism which requires stable mounting to minimize mechanical stress during operation.
How does the hydraulic-magnetic delay in the CA3-B0-34-635-431-C affect its suitability for protecting motor loads with high inrush currents compared to instantaneous trip breakers?
The CA3-B0-34-635-431-C employs a magnetic (hydraulic delay) mechanism that provides a time delay calibrated for the 35 A rating. This configuration allows the breaker to tolerate typical motor starting inrush without immediate tripping, while still delivering protection against sustained overloads and short circuits up to the interrupting capacity defined in the C-Series specifications.
When considering replacement of an existing 3-pole thermal-magnetic breaker with the Carling CA3-B0-34-635-431-C, what design implications should be evaluated regarding temperature stability?
Replacing a thermal-magnetic breaker with the CA3-B0-34-635-431-C introduces a hydraulic-magnetic design whose trip characteristics remain largely consistent across a wide ambient temperature range, unlike thermal elements that derate with rising temperature. This can reduce nuisance tripping in environments with variable cabinet temperatures but requires verification that the existing panel cutout and wiring accommodate the lever actuator and C-Series dimensions.
Is the CA3-B0-34-635-431-C appropriate for use in outdoor or harsh industrial enclosures subject to wide temperature swings and vibration?
The CA3-B0-34-635-431-C, as part of Carling's C-Series, utilizes a hydraulic-magnetic sensing mechanism that maintains stable trip behavior independent of ambient temperature variations. Its construction supports reliable operation in industrial settings where vibration levels and temperature fluctuations are present, provided the enclosure meets the overall environmental ratings of the application.
What configuration considerations arise when migrating from a single-pole or dual-pole breaker setup to the 3-pole CA3-B0-34-635-431-C for a 480 V AC three-phase system?
The CA3-B0-34-635-431-C provides three identical poles in a single mechanical assembly, enabling simultaneous disconnection of all phases in a 480 V AC system. Migration requires confirming that the panel mounting hole pattern matches the C-Series footprint and that terminal connections align with the chosen stud or screw options to maintain proper phase isolation and creepage distances.
For long-term reliability in continuous industrial operation, how does the hydraulic delay of the CA3-B0-34-635-431-C influence performance under frequent load cycling?
In the CA3-B0-34-635-431-C the hydraulic delay element helps dampen response to transient currents, resulting in repeatable trip timing that supports extended service life in applications with regular on/off cycling or inductive loads. Engineers often monitor auxiliary switch options if remote status indication becomes necessary over years of operation.
What are the practical differences and trade-offs when evaluating the CA3-B0-34-635-431-C against equivalent-rated breakers from other manufacturers for UL 489 applications?
The CA3-B0-34-635-431-C carries UL, CSA, and CCC approvals with a C-Series arc chute design that supports interrupting capacities up to 10,000 A in qualified configurations. Compared to alternatives, differences often appear in actuator feel, exact time-delay curves, and terminal styles; designers typically validate that the 35 A hydraulic-magnetic response curve meets the specific coordination needs of downstream components.
When designing redundant power distribution, how should the voltage ratings of the CA3-B0-34-635-431-C be applied across AC and DC sections?
The CA3-B0-34-635-431-C is rated 480 V AC and 125 V DC. In mixed systems, poles are commonly dedicated separately to AC phases or DC buses within these limits, with the multi-pole construction allowing coordinated tripping while requiring separate evaluation of dielectric withstand between poles and to ground.
Are there specific component selection factors to consider when pairing the CA3-B0-34-635-431-C with contactors or relays in an automation panel?
Selection around the CA3-B0-34-635-431-C focuses on ensuring the upstream or downstream devices coordinate with its 35 A rating and hydraulic delay curve to avoid overlap in trip regions. The breaker's lever position provides visual status, and its RoHS3 compliant, REACH unaffected status simplifies material compliance for the overall assembly.
What operating condition boundaries should be reviewed before deploying the CA3-B0-34-635-431-C in high-altitude or low-pressure industrial environments?
The CA3-B0-34-635-431-C performance is defined primarily by current and voltage ratings rather than pressure-dependent thermal effects. Its magnetic-hydraulic mechanism continues to deliver consistent protection at the 35 A level, though system designers verify that the overall panel dielectric and interrupting requirements remain satisfied under the reduced air density at altitude.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


CA3-B0-34-635-431-C

Carling Technologies

CIRCUIT BREAKER

In Stock: 1932

Submit RFQ