Choose your country or region.

Image may be representation.
See specs for product details.

C21-B0-12-660-311-E

In Stock 385 pcs Reference Price(In US Dollars)
2+
$81.0288
Manufacturer Part Number:
C21-B0-12-660-311-E
Manufacturer / Brand
Carling Technologies
Part of Description:
CIRCUIT BREAKER
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 385 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number C21-B0-12-660-311-E
Manufacturer / Brand Carling Technologies
Stock Quantity 385 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIRCUIT BREAKER
Lead Free Status / RoHS Status: ROHS3 Compliant
Voltage Rating - DC 80 V
Voltage Rating - AC 480 V
Series C
Package Bulk
Number of Poles 1
Mounting Type Panel Mount
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 60A
Breaker Type Magnetic (Hydraulic Delay)
Approval Agency CCC, CSA, TUV, UL
Actuator Type Rocker

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can C21-B0-12-660-311-E be used on a 480 VAC branch circuit with motor starting inrush, or is it better suited to resistive loads?
C21-B0-12-660-311-E is a magnetic (hydraulic delay) circuit breaker, so it is generally better matched to loads with short inrush events than a fast-acting thermal device. In a 480 VAC application, the C21-B0-12-660-311-E can be a practical fit when the downstream load has repetitive startup surges, such as motors, transformers, or capacitive input supplies, because the hydraulic delay helps reduce nuisance tripping. For designs with very high inrush or frequent cycling, the actual trip behavior should still be checked against the load profile, ambient temperature, and expected duty cycle.
Is C21-B0-12-660-311-E suitable for replacing a thermal breaker in an equipment panel without changing the cutout or user interface?
C21-B0-12-660-311-E may be a workable replacement only if the panel cutout, rocker actuator geometry, mounting method, and electrical ratings align with the existing design. Because it is a panel-mount rocker breaker, a direct swap is most likely when the original part uses the same form factor and similar terminal arrangement. The trip curve is also different from a thermal breaker, so a replacement using C21-B0-12-660-311-E can change nuisance-trip behavior and fault-clearing characteristics even when the mechanical fit is similar.
Can C21-B0-12-660-311-E be used on a DC load, and what should be checked before using it at 80 VDC?
C21-B0-12-660-311-E is rated for DC service up to 80 VDC, but DC interruption is usually more demanding than AC because the current does not cross zero naturally. Before using C21-B0-12-660-311-E on a DC circuit, the design should confirm that the fault current, wiring inductance, and source impedance stay within the breaker’s interruption capability and the system’s protective coordination strategy. For battery-backed or capacitive DC buses, engineers typically also verify conductor sizing, enclosure spacing, and arc management to avoid stress during fault clearing.
How does the rocker actuator on C21-B0-12-660-311-E affect panel design and serviceability?
The rocker actuator on C21-B0-12-660-311-E supports straightforward manual operation from the front panel, which simplifies maintenance access and user reset behavior in enclosed equipment. In panel layouts, the rocker profile should be checked for clearance behind the bezel, operator reach, and accidental actuation risk. For serviceable industrial equipment, the C21-B0-12-660-311-E can be convenient when technicians need visible on/off status at the panel without adding a separate switch, but the mechanical orientation and labeling strategy should still be reviewed for the final enclosure.
What should I consider if I want to use C21-B0-12-660-311-E in an industrial machine that runs continuously at elevated ambient temperature?
C21-B0-12-660-311-E can be used in continuous-duty industrial equipment, but ambient temperature, enclosure ventilation, and adjacent heat sources will influence its effective trip behavior. Hydraulic-delay breakers can drift in response to temperature, so a design that runs hot may see different trip timing than one tested at room temperature. For C21-B0-12-660-311-E, it is common to verify derating, panel airflow, terminal temperature rise, and nearby load current so the breaker remains stable over long operating periods.
Are there Carling or other equivalent part numbers that can replace C21-B0-12-660-311-E without changing the electrical design?
A replacement for C21-B0-12-660-311-E should be matched by mounting style, pole count, actuator type, current rating, AC/DC voltage rating, and trip characteristic rather than by part family alone. Within Carling Technologies, the closest alternatives are typically other C-series breakers with the same panel interface and similar ratings, but a different suffix can indicate changes in actuator, calibration, or construction details. When cross-referencing to another brand, the engineer should compare interruption ratings, dielectric spacing, terminal style, and agency approvals before assuming C21-B0-12-660-311-E is interchangeable.
Is C21-B0-12-660-311-E appropriate for renewable-energy, battery, or inverter-output applications?
C21-B0-12-660-311-E can fit some inverter-fed or battery-backed systems, but the suitability depends on the waveform, available fault current, and whether the circuit sees DC, quasi-DC, or AC output. For inverter outputs, the breaker’s behavior should be checked against the inverter’s current-limiting profile and any manufacturer requirements for branch protection. For battery or DC bus use, C21-B0-12-660-311-E should be validated at the actual system voltage and prospective fault current, since storage systems can deliver high surge energy even when the nominal voltage appears moderate.
How should I coordinate upstream protection with C21-B0-12-660-311-E so nuisance trips do not occur during normal operation?
C21-B0-12-660-311-E should be coordinated with upstream fuses, contactors, or breakers based on the expected load inrush, steady-state current, and fault-clearing sequence. Because it is a magnetic (hydraulic delay) device, C21-B0-12-660-311-E may tolerate brief surges better than a standard thermal element, but coordination still depends on the source impedance and the downstream load profile. In practice, engineers review time-current curves, selectivity targets, and worst-case startup conditions so the breaker handles branch-level faults without tripping during ordinary power-up events.
What reliability checks make sense if C21-B0-12-660-311-E will be used in equipment that is shipped globally or serviced over many years?
For global or long-life equipment, C21-B0-12-660-311-E should be checked for agency compatibility, environmental exposure, vibration, and access to spare parts. The model carries CCC, CSA, TUV, and UL approvals, which can simplify multi-market compliance, but the final system still needs verification against the destination installation standard. Long-term reliability planning for C21-B0-12-660-311-E usually includes periodic functional testing, terminal torque inspection, panel contamination control, and replacement planning so field service remains predictable over the product lifecycle.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


C21-B0-12-660-311-E

Carling Technologies

CIRCUIT BREAKER

In Stock: 385

SUBMIT RFQ