Choose your country or region.

Image may be representation.
See specs for product details.

3.6WKFHO355

In Stock 119 pcs Reference Price(In US Dollars)
1+
$2,716.0261
Manufacturer Part Number:
3.6WKFHO355
Manufacturer / Brand
Eaton - Bussmann Electrical Division
Part of Description:
FUSE CARTRIDGE 355A 3.6KVAC BOLT
Datasheets:
3.6WKFHO355(1).pdf3.6WKFHO355(2).pdf
Lead Free Status / RoHS Status:
RoHS Compliant
Stock Condition:
New original, 119 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number 3.6WKFHO355
Manufacturer / Brand Eaton - Bussmann Electrical Division
Stock Quantity 119 pcs Stock
Category Circuit Protection > Electrical, Specialty Fuses
Description FUSE CARTRIDGE 355A 3.6KVAC BOLT
Lead Free Status / RoHS Status: RoHS Compliant
Voltage Rating - AC 3.6 kV
Size / Dimension 2.992' Dia x 10.000' L (76.00mm x 254.00mm)
Series -
Response Time -
Package / Case Cylindrical, Blade Terminal (Bolt)
Package Bulk
Operating Temperature -
Mounting Type Requires Holder
Melting I²t 640000
Fuse Type Cartridge
Features -
DC Cold Resistance 345 µOhms
Current Rating (Amps) 355A
Class -
Breaking Capacity @ Rated Voltage 50kA
Approval Agency -
Applications -

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

How do I determine whether 3.6WKFHO355 is suitable for replacing a lower-voltage cartridge fuse in an existing medium-voltage system?
3.6WKFHO355 is a 3.6 kVAC Eaton - Bussmann Electrical Division cartridge fuse, so the replacement decision should start with the system’s actual line-to-line and transient voltage profile. If the installed circuit can experience steady-state or recovery voltages near or above the fuse’s 3.6 kVAC rating, 3.6WKFHO355 may not provide the same margin as the original part. In retrofit work, engineers typically verify not only nominal voltage but also switching transients, insulation coordination, and the holder’s creepage/clearance limits before using 3.6WKFHO355.
What should I check before using 3.6WKFHO355 in a custom holder or legacy fuse assembly?
3.6WKFHO355 requires a holder and is a cylindrical fuse with blade terminal bolt construction, so the holder must match its 2.992 in by 10.000 in physical envelope and bolted termination style. In practice, the main integration checks for 3.6WKFHO355 are mechanical retention, terminal alignment, contact pressure, and heat dissipation inside the enclosure. A holder intended for a different body length, diameter, or terminal geometry can create elevated contact resistance or assembly stress even if the current rating appears compatible.
Is 3.6WKFHO355 appropriate for motor protection, transformer protection, or feeder protection in industrial equipment?
3.6WKFHO355 can be used where a high-current cartridge fuse is needed at 355 A and 3.6 kVAC, but the suitability depends on the load profile and coordination target rather than the current rating alone. For motor or transformer circuits, engineers usually compare the fuse’s melting I²t of 640000.0 with the inrush and let-through energy of the protected equipment. If the downstream device has a high energization surge, 3.6WKFHO355 may be acceptable only if the upstream and downstream protection selectivity still works as intended.
Can 3.6WKFHO355 be used as a direct replacement if I only know the amp rating and not the exact fuse class?
3.6WKFHO355 should not be selected on amp rating alone. Cartridge fuses with the same current rating can have very different interrupting behavior, time-current curves, and physical dimensions. With 3.6WKFHO355, the 50 kA breaking capacity at rated voltage and its specific melting I²t matter for coordination and fault clearance. A direct replacement should match the original fuse’s voltage class, interrupting rating, physical format, and application intent.
How does the 50 kA breaking capacity of 3.6WKFHO355 affect design decisions?
The 50 kA breaking capacity of 3.6WKFHO355 defines the maximum prospective short-circuit current the fuse can interrupt at its rated voltage. In a practical design review, this value is compared against the available fault current at the installation point, including utility contribution and transformer impedance. If the prospective fault current exceeds 50 kA, 3.6WKFHO355 would not be an appropriate choice for that location, even if the continuous current rating is otherwise correct.
What thermal or connection issues should I consider when using 3.6WKFHO355 in a high-current enclosure?
At 355 A, contact quality and enclosure thermal management become critical. 3.6WKFHO355 has a listed DC cold resistance of 345 µOhms, so any additional resistance from loose bolts, oxidized interfaces, or mismatched hardware can increase localized heating. In compact enclosures, engineers typically verify torque, conductor lug compatibility, ventilation, and nearby component spacing to avoid temperature rise that can shorten fuse or holder life.
Is 3.6WKFHO355 a good option for applications with frequent load cycling or repeated energization?
3.6WKFHO355 may be usable in cyclical service, but repeated thermal cycling should be evaluated against the holder design and the system’s inrush profile. For frequent energization, the fuse element can experience cumulative stress from heating and cooling, especially if the circuit is close to the fuse’s continuous current limit. It is common to review measured load profiles and coordination margins before finalizing 3.6WKFHO355 in cyclic industrial duty.
What are the key differences to check if I am comparing 3.6WKFHO355 with other Eaton - Bussmann Electrical Division fuse cartridges?
When comparing 3.6WKFHO355 with other Eaton - Bussmann Electrical Division cartridge fuses, the main differences to verify are voltage rating, interrupting capacity, body size, terminal style, and time-current characteristics. Two parts can both be Eaton - Bussmann Electrical Division products and still differ significantly in fit or protection behavior. For 3.6WKFHO355, the 3.6 kVAC rating, 355 A current rating, 50 kA breaking capacity, and bolt-style cylindrical form factor should all be matched to the application requirements.
Can 3.6WKFHO355 be used in a DC circuit if the current and interrupt ratings look sufficient?
3.6WKFHO355 is specified at 3.6 kVAC, so its suitability for DC service cannot be assumed from the AC rating alone. DC interruption is generally more demanding because there is no current zero crossing to assist extinction. If the circuit is DC, the designer should use a fuse specifically rated for the DC voltage and fault conditions rather than relying on 3.6WKFHO355 unless the manufacturer’s DC rating is explicitly confirmed for the exact use case.
What replacement risks should I consider when swapping 3.6WKFHO355 into older switchgear or OEM equipment?
In older switchgear, the main risks are dimensional mismatch, holder wear, and coordination changes with upstream and downstream devices. 3.6WKFHO355 is a 2.992 in by 10.000 in cylindrical fuse with bolted blade terminals, so even slight differences in fuse length, end fitting geometry, or mounting method can affect contact integrity. Engineers often inspect the holder spring force, existing torque hardware, and signs of heat discoloration before installing 3.6WKFHO355 in legacy equipment.
How should I interpret the melting I²t value of 3.6WKFHO355 during protection coordination?
The melting I²t of 3.6WKFHO355, listed as 640000.0, is useful when checking whether the fuse will clear a fault before damage occurs to cables, semiconductors, or transformer windings. In coordination studies, this figure is compared with the withstand energy of the protected components and the let-through energy of upstream devices. If the protected load has a low thermal tolerance, 3.6WKFHO355 may need to be evaluated against actual fault and inrush waveforms rather than nominal amperage alone.
Does 3.6WKFHO355 have any special storage, handling, or long-term reliability concerns for industrial inventories?
3.6WKFHO355 is listed as RoHS compliant and has no stated operating temperature on the provided data, so long-term storage practices should focus on keeping the fuse clean, dry, and mechanically protected. For industrial spares, the practical concerns are corrosion at the terminals, contamination of the contact surfaces, and preserving the packaging integrity in bulk storage. Before installation, technicians typically inspect 3.6WKFHO355 for signs of oxidation, damage, or contamination that could increase contact resistance after assembly.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


3.6WKFHO355

Eaton - Bussmann Electrical Division

FUSE CARTRIDGE 355A 3.6KVAC BOLT

In Stock: 119

Submit RFQ