Choose your country or region.

Image may be representation.
See specs for product details.

2C10UR

In Stock 3034 pcs Reference Price(In US Dollars)
1+
$12.1362
Manufacturer Part Number:
2C10UR
Manufacturer / Brand
Altech Corporation
Part of Description:
CIRC BREAK DP 10A MCB C CHAR UL1
Datasheets:
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 3034 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number 2C10UR
Manufacturer / Brand Altech Corporation
Stock Quantity 3034 pcs Stock
Category Circuit Protection > Circuit Breakers
Description CIRC BREAK DP 10A MCB C CHAR UL1
Lead Free Status / RoHS Status: ROHS3 Compliant
Voltage Rating - AC 480 V
Series UR
Package Bulk
Number of Poles 2
Mounting Type DIN Rail
Illumination Voltage (Nominal) -
Illumination None
Current Rating (Amps) 10A
Breaker Type Thermal Magnetic
Base Product Number 2C10
Approval Agency CE, cURus, UL1077
Actuator Type Lever

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

Can I use Altech Corporation 2C10UR as a direct replacement for a 2-pole 10A DIN rail breaker in an existing panel?
Altech Corporation 2C10UR can often be evaluated as a replacement when the panel already uses a DIN rail, 2-pole form factor, and a 10A thermal-magnetic protection scheme. Before substituting 2C10UR, verify rail compatibility, terminal spacing, available enclosure depth, and whether the existing wiring method matches the breaker’s terminal style. Also confirm the interrupting and coordination requirements of the circuit, since a replacement breaker must fit both mechanically and electrically, not just match the current rating.
Is Altech Corporation 2C10UR suitable for protecting mixed AC/DC control circuits?
Altech Corporation 2C10UR is rated for 480 V AC and is described as AC/DC in the product summary, so it can be considered for some mixed-control environments. In practice, the determining factors are the actual DC voltage, the available fault current, and whether the downstream load has inrush or inductive characteristics that affect thermal-magnetic trip behavior. For DC use, confirm the manufacturer’s application guidance and derating rules for the exact system voltage and polarity arrangement before design-in.
What should I check before using Altech Corporation 2C10UR in a motor control or inductive load application?
For Altech Corporation 2C10UR, the main checks are starting current, inrush duration, and whether nuisance tripping could occur during startup or switching. Thermal-magnetic breakers respond differently than fuses or electronic protectors, so a load with a high inrush profile may require coordination testing. If the circuit includes solenoids, transformers, or small motors, validate that the 10A curve and 2-pole configuration support the real operating profile across temperature and expected ambient conditions.
Can Altech Corporation 2C10UR be used as the main disconnect for equipment panels?
Altech Corporation 2C10UR is a circuit breaker, but whether it can serve as a main disconnect depends on the panel design, local code, and the required disconnecting function. Some installations need a dedicated isolator or a breaker with specific switching and lockout characteristics. If the panel requires clear lockout/tagout capability or visible isolation, confirm that the actuator and installation method meet the governing safety and maintenance workflow.
How does the 2-pole design of Altech Corporation 2C10UR affect system wiring and protection?
The 2-pole configuration on Altech Corporation 2C10UR is useful when both conductors need simultaneous interruption, such as line-line circuits or applications where a two-conductor feed must be isolated together. In design terms, this can simplify maintenance and improve disconnection consistency, but it also means you must plan for the correct upstream feed arrangement and ensure both poles are rated for the intended system voltage and fault conditions. It is not the same as using two independent single-pole devices.
What is the practical difference between Altech Corporation 2C10UR and a fuse-based protection approach?
Altech Corporation 2C10UR offers resettable thermal-magnetic protection, while a fuse provides a one-time interruption after fault clearing. In industrial control panels, a breaker like 2C10UR can reduce downtime because it can be reset after a trip, but a fuse may offer different let-through characteristics and sometimes better coordination in very high fault current scenarios. The right choice depends on selectivity, serviceability, spare parts strategy, and the type of load being protected.
Can Altech Corporation 2C10UR be installed in a high-vibration industrial environment?
Altech Corporation 2C10UR is DIN rail mounted, which is common in industrial enclosures, but high vibration environments still require attention to rail retention, enclosure stiffness, and conductor strain relief. Verify that the DIN rail and terminal terminations are secured according to the panel build standard, because vibration-related loosening can affect both mechanical retention and electrical contact quality over time. Periodic inspection is often used in these environments.
What should I consider when selecting Altech Corporation 2C10UR for long-term operation in hot enclosures?
For Altech Corporation 2C10UR, ambient temperature and enclosure heat rise can shift thermal trip behavior and reduce available margin for continuous load. If the breaker is installed near heat-generating components such as power supplies or drives, the effective operating current may need to be reduced. In long-life industrial use, it is common to evaluate enclosure temperature, spacing, ventilation, and load profile together rather than relying on current rating alone.
Is Altech Corporation 2C10UR a good choice for replacing a different brand 10A UL1077 DIN rail breaker?
Altech Corporation 2C10UR may be a candidate replacement for another 10A UL1077 DIN rail breaker if the mechanical footprint, trip characteristics, terminal style, and panel certification requirements align. Even when the current rating matches, different brands can vary in handle geometry, pole spacing, trip tolerance, and accessory compatibility. In retrofit work, it is usually necessary to verify fit, function, and any impact on the panel’s original approvals.
Can Altech Corporation 2C10UR be used in equipment that requires CE and cURus compliance?
Altech Corporation 2C10UR carries CE, cURus, and UL1077 approvals, which makes it suitable for many equipment builds that need those markings. For a final product, however, the overall compliance depends on the complete assembly, the application category, and the enclosure design, not just the breaker itself. The breaker’s approvals help with component selection, but the end equipment still needs system-level evaluation.
How do I determine whether Altech Corporation 2C10UR will coordinate properly with upstream protection?
Coordination for Altech Corporation 2C10UR depends on the upstream protective device’s trip curve, available fault current, and the downstream circuit’s fault contribution. A 10A thermal-magnetic breaker may coordinate well in some control-panel branches, but not in all feeder arrangements. Engineers typically compare time-current characteristics, prospective short-circuit current, and the required selectivity level to avoid unnecessary upstream trips during a downstream fault.
Are there any installation concerns when using Altech Corporation 2C10UR on a DIN rail with other dense components?
With Altech Corporation 2C10UR, panel density matters because terminal access, wire bending radius, and heat dissipation can become limiting factors. If adjacent devices are closely packed, it may be harder to maintain serviceability or prevent thermal coupling from nearby components. Plan for enough clearance to route conductors cleanly and to allow the breaker handle to be operated without interference from adjacent hardware.
What are the risks of using Altech Corporation 2C10UR on a circuit with frequent switching?
Altech Corporation 2C10UR is a protective device rather than a control contactor, so frequent operational switching can add wear to the mechanism if it is used as a regular on/off device. If a circuit is opened and closed repeatedly, verify the expected mechanical endurance and consider whether a dedicated switch or contactor is more appropriate for the duty cycle. For maintenance isolation, occasional operation is typically a better fit than routine switching.
If I need a North American replacement for Altech Corporation 2C10UR, what should I compare first?
When looking for a North American replacement for Altech Corporation 2C10UR, compare the UL category, pole count, voltage rating, trip type, and DIN rail footprint first. Because 2C10UR is a thermal-magnetic 2-pole 10A device, a substitute should match not only the electrical rating but also the protection behavior and panel mounting expectations. You should also check whether the replacement affects terminal compatibility, label space, or system documentation.
Is Altech Corporation 2C10UR appropriate for equipment that may experience short-duration surge currents?
Altech Corporation 2C10UR can be suitable where brief surge currents are expected, but the outcome depends on the size and duration of the surge relative to the thermal-magnetic curve. Devices with transformers, capacitors, or charging circuits can produce startup peaks that may not indicate a fault. If surges are part of normal operation, it is wise to validate the breaker against real waveform data to avoid unintended trips while still maintaining protection against genuine overloads and short circuits.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


2C10UR

Altech Corporation

CIRC BREAK DP 10A MCB C CHAR UL1

In Stock: 3034

Submit RFQ