Choose your country or region.

Image may be representation.
See specs for product details.

0734030412

Manufacturer Part Number:
0734030412
Manufacturer / Brand
Molex
Part of Description:
FAKRA P SEALED FOR RG174 NO CLIP
Datasheets:
Lead Free Status / RoHS Status:
RoHS Compliant
Stock Condition:
New original, 38046 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number 0734030412
Manufacturer / Brand Molex
Stock Quantity 38046 pcs Stock
Category Connectors, Interconnects > Coaxial Connectors (RF) - Coaxial Connector (RF) Assemblies
Description FAKRA P SEALED FOR RG174 NO CLIP
Lead Free Status / RoHS Status: RoHS Compliant
Series *
Package Bulk
Base Product Number 073403

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

How should Molex 0734030412 be integrated when the cable is RG174 and the connector is specified as sealed/no clip?
Molex 0734030412 is intended for RG174 in a sealed FAKRA interface, so the main integration check is whether the cable construction matches the termination method and the housing seal requirement. In practice, the cable outer diameter, braid coverage, and jacket material need to match the connector’s seal path and strain relief so the assembly maintains retention and environmental sealing after crimp or assembly. If the design uses repeated vibration or field service, confirm that the no-clip variant still meets the retention strategy of the mating system and that the harness routing does not load the termination.
Can Molex 0734030412 be used in a design that needs field replacement or serviceable cable assemblies?
Molex 0734030412 can be used in serviceable assemblies, but the sealed construction and RG174-specific fit mean the replacement process should follow the same cable prep, crimp quality, and seal inspection used in production. For field replacement, the practical questions are whether the assembly can be reterminated without compromising the seal, whether the service team has the correct tooling, and whether the mating connector family still provides the required retention after repeated disconnects.
What should be checked before using Molex 0734030412 as a replacement for another FAKRA RF connector?
When replacing another FAKRA RF connector with Molex 0734030412, compare the key mechanical and system-level details: keying code, cable compatibility, sealing level, retained-interface style, and the mating partner’s exact FAKRA geometry. Two connectors can look similar and still differ in coding or retention features, which affects interchangeability and harness compatibility. The replacement also needs to be evaluated for the cable’s RF performance, since a different termination style can change return loss and assembly repeatability.
Is Molex 0734030412 suitable for automotive or harsh-environment RF harnesses?
Molex 0734030412 is a sealed FAKRA connector, so it is a natural fit for outdoor or vehicle-mounted RF harnesses where moisture, dust, and vibration need to be considered. The design should still be validated against the actual operating environment: connector sealing, harness bend radius, strain relief, and vibration exposure all affect long-term stability. For locations near heat sources or where salt spray is possible, the complete cable assembly and mating interface should be qualified as a system rather than assuming the connector alone covers the requirement.
What design issues can appear if Molex 0734030412 is used with the wrong coaxial cable instead of RG174?
Molex 0734030412 is specified for RG174, so using a different coax can create fit, seal, and electrical inconsistencies. A larger cable may not seat correctly in the rear seal or crimp area, while a smaller cable can leave the termination under-supported and reduce strain relief. Even if the connector can be assembled, impedance behavior and assembly repeatability may drift if the dielectric and shield structure differ from the intended cable type.
How does the no-clip version of Molex 0734030412 affect mating retention and installation?
Molex 0734030412 uses a no-clip configuration, so retention depends on the connector system’s built-in latch geometry and mating interface rather than an added clip feature. In an application with vibration or frequent movement, the designer should check whether the mating connector provides enough retention on its own and whether harness strain is relieved before the connector. Installation teams should also verify that the connector seats fully and that pull forces remain within the assembly’s expected handling limits.
What should engineers verify if Molex 0734030412 is being considered for long-life industrial use?
For long-life industrial use, Molex 0734030412 should be evaluated for connector seal integrity, cable aging, vibration exposure, and the stability of the mating contact interface over time. Seal performance can change if the harness is exposed to thermal cycling or contamination during assembly. It is also practical to check whether the chosen RG174 cable jacket remains flexible enough for routing without stressing the termination, because repeated flexing can be a larger failure driver than the connector body itself.
Can Molex 0734030412 be mixed with non-FAKRA RF connectors in the same platform?
Molex 0734030412 can be part of a mixed RF platform, but the system-level implications need attention. If the platform includes other connector families, the engineering team should confirm mechanical keying, impedance continuity, and serviceability so technicians do not create incompatible harnesses during assembly or repair. Mixed connector strategies often work best when each port is clearly designated by function and cable type, with mating restrictions enforced by the hardware.
What trade-offs should be considered when selecting Molex 0734030412 instead of an alternative Molex FAKRA part number?
Choosing Molex 0734030412 over another Molex FAKRA part number usually comes down to cable match, sealing style, and retention details. A different Molex option may support another cable size, a different clip arrangement, or a different assembly flow, which can affect tooling and inventory. The practical trade-off is whether the alternative simplifies manufacturing or service without changing the RF path, sealing behavior, or connector keying required by the end product.
What are the typical integration risks when routing Molex 0734030412 in a compact enclosure?
With Molex 0734030412 in a compact enclosure, the main risks are bend radius violations, connector back-shell interference, and stress on the sealed cable exit. RG174 is relatively manageable in tight spaces, but excessive bending near the rear of the connector can reduce termination durability and compromise seal integrity. It is usually helpful to reserve enough clearance for mating, unlatching, and inspection so the harness does not need to be forced into position during assembly or maintenance.
How should Molex 0734030412 be evaluated for RF performance in a design review?
Molex 0734030412 should be reviewed together with the full cable assembly, because connector behavior is only part of the RF result. Engineers typically check impedance consistency, return loss across the operating band, assembly repeatability, and the effect of the cable transition at the connector end. If the application is sensitive to insertion loss or reflections, a prototype measurement on the exact RG174 harness is more useful than relying on connector family compatibility alone.
What should be checked before approving Molex 0734030412 as a drop-in replacement in production?
Before approving Molex 0734030412 as a drop-in replacement, confirm the mating key, cable termination geometry, seal performance, and harness drawing revision against the existing assembly. A drop-in replacement is only practical if the connector footprint, tooling, and inspection criteria stay aligned with the current production process. It is also advisable to verify that the replacement does not alter field assembly steps, because small changes in connector retention or rear seal geometry can affect yield and service handling.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


0734030412

Molex

FAKRA P SEALED FOR RG174 NO CLIP

In Stock: 38046

SUBMIT RFQ