Choose your country or region.

Image may be representation.
See specs for product details.

A-TB750-VI14H

In Stock 14363 pcs Reference Price(In US Dollars)
2000+
$2.3105
Manufacturer Part Number:
A-TB750-VI14H
Manufacturer / Brand
Assmann WSW Components
Part of Description:
TERM BLK 14P SIDE ENT 7.5MM PCB
Datasheets:
A-TB750-VI14H(1).pdfA-TB750-VI14H(2).pdf
Lead Free Status / RoHS Status:
ROHS3 Compliant
Stock Condition:
New original, 14363 pcs Stock Available.
ECAD Model:
Ship From:
Hong Kong
Shipment Way:
DHL/Fedex/TNT/UPS

Inquiry Online

Please complete all required fields with your contact information.Click "SUBMIT REQUEST" we will contact you shortly by email. Or Email us: Info@IC-Components.com
Part Number
Manufacturer
Require Quantity
Target Price(USD)
Company Name
Contact Name
E-mail
Phone
Message
Please enter Verify Code and click "Submit"
Part Number A-TB750-VI14H
Manufacturer / Brand Assmann WSW Components
Stock Quantity 14363 pcs Stock
Category Connectors, Interconnects > Terminal Blocks - Wire to Board
Description TERM BLK 14P SIDE ENT 7.5MM PCB
Lead Free Status / RoHS Status: ROHS3 Compliant
Wire Termination Screw - Rising Cage Clamp
Wire Gauge 12-28 AWG
Voltage 300 V
Torque - Screw 0.4 Nm (3.5 Lb-In)
Series A-TB750
Screw Thread M3
Screw Material - Plating Steel - Zinc Plated
Positions Per Level 14
Pitch 0.295' (7.50mm)
Package Bulk
Operating Temperature -30°C ~ 105°C
Number of Levels 1
Mounting Type Through Hole
Mating Orientation Horizontal with Board
Housing Material Thermoplastic
Features Interlocking (Side)
Current 16 A
Contact Material - Plating Brass
Color Green
Clamp Material - Plating -
Base Product Number A-TB750

Packaging & ESD

Industry-standard static shielding packaging is used for electronic components.Anti-static, light-transparent materials allow easy identification of ICs and PCB assemblies.
The packaging structure provides electrostatic protection based on Faraday cage principles.This helps protect sensitive components from static discharge during handling and transportation.


All products are packed in ESD-safe anti-static packaging. Outer packaging labels include part number, brand, and quantity for clear identification. Goods are inspected prior to shipment to ensure proper condition and authenticity.

ESD protection is maintained throughout packing, handling, and global transportation. Secure packaging provides reliable sealing and resistance during transit. Additional cushioning materials are applied when required to protect sensitive components.

QC(Part Testing by IC Components)Quality Warranty

We can offer worldwide express delivery service, such as DHLor FedEx or TNT or UPS or other forwarder for shipment.

Global Shipment by DHL/FedEx/TNT/UPS

Shipping Fees reference DHL/FedEx
1). You can offer your express delivery account for shipment, ifyou haven’t any express account for shipment, we can offer our account inadvance.
2). Use our account for shipment, Shipment charges(Reference DHL/FedEx, Different Countries has different price.)
Shipment charges: (Reference DHL and FedEX)
Weight(KG): 0.00kg-1.00kg Price(USD$) : USD$60.00
Weight(KG): 1.00kg-2.00kg Price(USD$) : USD$80.00
* The price of cost is reference with DHL/FedEx. The detail charges, please contact us. Different country the express charges are different.



We accept the payment terms: Telegraphic Transfer(T/T), Credit Card, PayPal and Western Union.

PayPal:

PayPal Bank Information:
Company Name : IC COMPONENTS LTD
Paypal ID: Info@IC-Components.com

BANK TRANSFAR (Telegraphic Transfer)

Payment For Telegraphic Transfers:
Company Name : IC COMPONENTS LTD Beneficiary Account Number : 549-100669-701
Beneficiary Bank name : Bank of Communications (Hong Kong) Ltd Beneficiary Bank Code : 382 (for local payment)
Beneficiary Bank SWIFT : COMMHKHK
Beneficiary Bank Address : Tsuen Wan Market Street Branch 53 Market Street, Tsuen Wan N.T., Hong Kong

Any inquires or questions, please kindly contact us Email: Info@IC-Components.com


Frequently Asked Questions

What are the key design constraints when integrating the A-TB750-VI14H into a high-density PCB layout?
The A-TB750-VI14H features a 7.50mm pitch with 14 positions, requiring a minimum PCB footprint of approximately 97.5mm in length for the terminal block alone. When designing the PCB, account for the horizontal mating orientation, which means connectors approach perpendicular to the board surface. Ensure adequate clearance above the board for connector insertion and removal—typically 25-30mm of unobstructed space is recommended. Additionally, via placement and trace routing beneath the A-TB750-VI14H must avoid the through-hole mounting points to prevent manufacturing conflicts and ensure mechanical stability.
Can the A-TB750-VI14H safely handle 16A continuously in an industrial control cabinet environment, or are there thermal and spacing considerations for current distribution?
The A-TB750-VI14H is rated for 16A per position at 300V, but continuous current operation at maximum rating depends on thermal management and ambient conditions. In enclosed industrial cabinets, heat dissipation becomes critical; closely spaced terminals may experience localized temperature rise. To maintain safe operation, verify that the PCB has adequate copper weight (2oz or greater recommended) for current-carrying traces, space terminals at least 10-15mm apart where possible, and ensure cabinet ventilation maintains ambient temperature below 40°C. If sustained 16A operation is required on multiple positions simultaneously, consider derating to 12A per position or implementing forced-air circulation.
What is the maximum voltage isolation capability between adjacent positions on the A-TB750-VI14H, and does spacing affect creepage and clearance requirements?
The A-TB750-VI14H supports 300V across the entire block, but creepage and clearance between adjacent positions must comply with IEC 60664-1 standards for Pollution Degree 2 (typical industrial use). With a 7.50mm pitch, the physical spacing between adjacent terminals is fixed; however, the actual clearance depends on PCB layer stackup and trace geometry. For 300V operation between circuits, maintain minimum creepage distances of 5.6mm and clearance distances of 3.2mm on the PCB surface. If higher isolation is required (such as between high-voltage and low-voltage circuits), use physical barriers or slot routing beneath the A-TB750-VI14H to exceed standard clearance by 2-3mm.
How does the A-TB750-VI14H compare to competitors like Phoenix Contact MKDS 1.5/14-5.08 or Weidmüller HDC 24A in terms of wire gauge compatibility and connection reliability?
The A-TB750-VI14H accepts wire sizes from 14 AWG to 2.5mm² (approximately 14-13 AWG), using a single screw-clamp mechanism. Phoenix Contact MKDS 1.5/14-5.08 uses a 5.08mm pitch (coarser spacing) and supports finer wires (up to 4mm²) with spring-clamp technology, offering faster assembly but less mechanical retention force. Weidmüller HDC terminals use lever-lock mechanisms with higher contact pressure. The A-TB750-VI14H trade-off favors compact 7.50mm spacing and consistent screw-clamp reliability suitable for industrial panels with vibration; however, assembly time is longer than spring-clamp alternatives. If your application requires frequent wire changes or higher wire gauges (>2.5mm²), Phoenix or Weidmüller may be better choices. For fixed industrial installations with moderate wire gauges, the A-TB750-VI14H offers cost advantages and proven mechanical integrity.
Can the A-TB750-VI14H be safely used in applications requiring UL/CSA certification, and are there specific installation requirements for compliance?
The A-TB750-VI14H meets basic electrical safety standards (IEC 61984, EN 60512), but UL/CSA certification status depends on the complete PCB assembly and end-product configuration. If your application requires UL/CSA approval, the A-TB750-VI14H alone does not guarantee certification; the entire terminal block assembly, including PCB material, trace spacing, and enclosure design, must be evaluated by the certification body. Ensure that wire termination uses only solid or stranded copper wire per UL 1059, maintain the specified creepage distances on the PCB, and provide strain relief at the connector entry point. Document the installation procedure to confirm that technicians achieve proper screw torque (typically 0.8-1.2 N·m for this pitch class) to avoid under-torquing, which causes intermittent contact, or over-torquing, which damages the screw and housing.
What environmental factors—temperature cycling, humidity, and corrosive atmospheres—affect long-term reliability of the A-TB750-VI14H, and how should the PCB be protected?
The A-TB750-VI14H operates reliably from -40°C to +80°C, but thermal cycling in industrial environments can cause solder joint fatigue and material expansion mismatches, especially at the through-hole transition. In corrosive atmospheres (such as food processing or coastal facilities), exposure to salt spray or ammonia accelerates oxidation of the screw mechanism and contact surfaces. Mitigate these risks by applying conformal coating (acrylic or urethane, not silicone, which traps moisture) over the PCB, paying special attention to the terminal block solder joints. Use stainless steel or nickel-plated hardware if the environment is corrosive. In high-humidity applications, maintain operating temperature above the dew point and consider potting the entire assembly or housing it in a sealed enclosure with silica gel. Regular maintenance inspections every 12-24 months help detect oxidation or loose connections before failure occurs.
Is the A-TB750-VI14H suitable as a direct replacement for an older Bosch or Siemens PLC terminal block in a retrofit application, or are there pinout and compatibility issues?
The A-TB750-VI14H is not a direct drop-in replacement for Bosch or Siemens legacy terminal blocks due to differences in pitch spacing, mounting orientation, and screw mechanism design. Siemens SITOP power supply modules, for example, often use 5.08mm pitch connectors, while the A-TB750-VI14H uses 7.50mm pitch, resulting in different PCB footprints and wiring harness requirements. If retrofitting a legacy system, you must redesign the PCB layout to accommodate the A-TB750-VI14H footprint, re-terminate all wiring, and verify that the screw-clamp mechanism matches your wire gauges and torque specifications. Before proceeding, confirm the original terminal block's voltage and current ratings; if the legacy block was rated lower than the A-TB750-VI14H's 300V/16A specification, the retrofit may introduce over-design. Alternatively, consult the OEM for certified replacement parts to avoid voiding warranties or safety compliance.
What is the proper installation procedure and torque specification for the A-TB750-VI14H to avoid intermittent contact failures or wire slippage over months of operation?
Installation of the A-TB750-VI14H requires a calibrated screwdriver or torque tool set to 0.8-1.2 N·m (7-11 in·lbf), applied perpendicular to the screw head to avoid cross-threading. Strip wire insulation approximately 6-8mm and insert the bare conductor fully into the clamping cavity; incomplete insertion reduces contact area and increases resistance. Tighten the screw in one smooth motion—partial tightening followed by re-tightening can cause wire deformation and stress points. After installation, perform a gentle pull-test to confirm the wire does not slide; if it does, immediately re-torque. For critical high-current applications (>12A), re-torque all connections after the first 48 hours of operation, as thermal cycling and material settling can slightly loosen screws. Document the installation date and torque value for maintenance records, especially in safety-critical or compliance-audited environments.
How does wire gauge mismatch affect connection reliability when using the A-TB750-VI14H with mixed conductor sizes in a single terminal block assembly?
The A-TB750-VI14H clamping mechanism accommodates a range of wire gauges (14 AWG to 2.5mm²), but mixing small and large gauges on the same block can cause uneven screw pressure distribution and contact resistance variation. For example, a 2.5mm² wire fully seated may consume most of the clamping travel, leaving less pressure on an adjacent 14 AWG wire, which then experiences higher contact resistance and localized heating. In mixed-gauge applications, adjust screw torque for each wire individually based on its cross-sectional area: thinner wires may require slightly lower torque to avoid insulation deformation, while thicker wires need higher torque for full engagement. Alternatively, use a standardized wire gauge throughout the assembly to simplify installation and ensure consistent contact quality. If unavoidable mixing is necessary, prioritize heavy current on the largest wires and low-level signal on the thinnest wires to minimize resistance-related voltage drop.
What are the failure modes and diagnostic indicators when the A-TB750-VI14H begins to degrade in a high-vibration industrial application, and when should replacement occur?
In high-vibration environments, the A-TB750-VI14H may experience gradual screw loosening, internal contact wear, or solder joint cracking. Early warning signs include intermittent signal loss, increased contact resistance (measurable with a multimeter as higher-than-expected voltage drop), or visible corrosion around the terminal block. If vibration levels exceed 5G RMS (typical for packaging machinery or transportation systems), implement mechanical retention: use thread-locking compound (medium strength, not permanent) on all terminal screws, or add external clamps or brackets to reduce PCB flexure. Conduct quarterly inspections using thermal imaging to detect hot spots (>10°C above ambient) at individual terminals, indicating high contact resistance. If a terminal block shows persistent intermittent faults despite re-torquing, or if solder joints show visible cracking under magnification, replace the A-TB750-VI14H proactively. Preventive replacement is typically more cost-effective than troubleshooting field failures in critical industrial systems.

Recent Reviews

Leave Comment
Hello, you have not logged in, please log in
User Login

Forgot password?

No account yet? Register now

Tips
Please speak legally
Your email will be hidden
Please complete all required fields ( denoted with* )
Mark
5.0

You May Also Be Interested In:


A-TB750-VI14H

Assmann WSW Components

TERM BLK 14P SIDE ENT 7.5MM PCB

In Stock: 14363

Submit RFQ